My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 2ND FLOOR 2025-06-30
>
Address Records
>
PACIFIC AVE
>
916
>
2ND FLOOR
>
916 PACIFIC AVE 2ND FLOOR 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:39:19 PM
Creation date
5/2/2025 1:34:44 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING PANEL 4N1 (NORMAL BRANCH) (NEW WORK) FIRST FLOOR <br />VOLTAGE: 48013 PH, 4 W <br />TYPE: PANELBOARD <br />ENCLOSURE: NEMA1 <br />SURFACE <br />FEEDER/BRANCH CIRCUIT DEVICES: <br />BOLT -ON CIRCUIT BREAKERS <br />FULLAIC RATING '. 14,000A <br />SERIES AIC RATING: 65,000A <br />ELECTRICAL LOAD <br />CALCULATION <br />CONN. <br />EXIST. <br />LOAD <br />NEW <br />A <br />TOTAL <br />DEMAND <br />FACTOR <br />DEMAND <br />LOAD (VA) <br />Lighting <br />Pure... <br />Gen. Puose 0.1..(First lO KVA) <br />Gen, Purpose Outlets (Remainder) <br />Special Purpose Outlets <br />Mechanical Equipment <br />Kitchen Equipment &Appliances <br />Miscellaneous <br />25%Largest Motor <br />14202.0 <br />9720.0 <br />0.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />50.0 <br />280.0 <br />1340.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />14252.0 <br />10000.0 <br />1340.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />1.25 <br />1.00 <br />0.50 <br />1.00 <br />1.00 <br />100 <br />1.00 <br />178101.0 <br />1.000.0 <br />670.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />BUSSING'. MANUFACTURER'S STANDARI <br />CONTINUOUS RATING: 225 A <br />FULLAICRATING: 55,000A <br />SERIESAICRATING'. NONE <br />SPECIAL PROVISIONS: <br />MASTER NAMEPLATE <br />GROUND BAR <br />MAIN: LUGS ONLY <br />LOCATION. BOTTOM <br />TOTAL LOAD <br />TOTAL AMPS <br />239220 <br />28.8 <br />16700 <br />2.0 <br />255920 <br />30.8 <br />284850 <br />34.3 <br />CONN. <br />LOAD (VA) <br />FEEDER/BRA NCHCIRCUIT <br />DESCRIPTION E <br />BKR <br />AMP/P <br />CKT <br />NO <br />BUS <br />(PHASE) <br />CKT <br />NO <br />BKR <br />AMP/P <br />FEE DERIBRANCH CIRCUIT <br />DESCRIPTION -' <br />CONN. <br />LOAD (VAj <br />727.0 <br />LTG- CORRIDOR 2ND FLOOR 1 <br />2011 <br />1 <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />2 <br />2011 <br />LTG-SURGERYHALLWAY <br />13]6.0 <br />1204.0 <br />LTG- CORRIDOR 2ND FLOOR NORTH <br />2O11 <br />3 <br />4 <br />2011 <br />LTG-OFFICES/DR LOUNGE <br />516.0 <br />7242.0 <br />7174.0 <br />PANEL 2N2S-SECOND FLOOR <br />70/2 <br />1 <br />5 <br />7 <br />6 <br />20/1 <br />LTG - STAFF LOUNGE/STOR <br />344.0 <br />8 <br />20/1 <br />LTG - SURGERYHALLWAY <br />1505.0 <br />00 <br />SPACE <br />9 <br />10 <br />20/1 <br />LTG -STERILE CORE <br />8600 <br />00 <br />SPACE <br />11 <br />12 <br />20/1 <br />LTG- SURGERYCENTRAL AREA <br />17200 <br />0.0 <br />SPACE <br />13 <br />14 <br />20/1 <br />LTG - HOLD/CORR.ILOBBY <br />1204.0 <br />0.0 <br />SPACE <br />15 <br />16 <br />20/1 <br />LTG - OFFICE/ADMINNJAIFING <br />1075.0 <br />00 <br />SPACE <br />17 <br />18 <br />2011 <br />LTG - MAIN LOBBY <br />6450 <br />00 <br />SPACE <br />19 <br />20 <br />SPACE <br />00 <br />0.0 <br />SPACE <br />21 <br />22 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />23 <br />24 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />25 <br />26 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />27 <br />28 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />29 <br />30 <br />SPACE <br />0.0 <br />00 <br />SPACE <br />31 <br />32 <br />SPACE <br />00 <br />0.0 <br />SPACE <br />33 <br />34 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />35 <br />36 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />37 <br />38 <br />SPACE <br />0.0 <br />00 <br />SPACE <br />39 <br />40 <br />SPACE <br />00 <br />0.0 <br />SPACE <br />41 <br />42 <br />SPACE <br />0.0 <br />MAIN LUGS <br />NOTES: <br />(1) MODIFIED EXISTING CIRCUIT ON EXISTING CIRCUIT BREAKER <br />(2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. <br />(3) EXISTING LOADS ARE CALCULATED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND VERIFIED BYFIELD OBSERVATION. <br />(4) THE WORK IN THIS PROJECT RESULTS IN NO LOAD INCREASE TO THIS PANEL. THEREFORE NO UPSTREAM LOADS ARE CALCULATED. <br />EXISTING TRANSFORMER T2N2S (NORMAL BRANCH) <br />KVA: 37.5 PHASE: 1 <br />TYPE: DRY <br />ELECTRICAL LOAD <br />CONN. <br />LOAD (VA) <br />DEMAND <br />DEMAND <br />ENCLOSURE: NEMA1 <br />CALCULATION <br />EXIST. <br />NEW <br />I TOTAL <br />IFACTOR <br />LOAD (VA) <br />Llghtl ng <br />3076.0 <br />0.0 <br />3076.0 <br />1.25 <br />3845.0 <br />PRIMARY: 480V <br />MOUNTING: FLOOR <br />SECONDARY 120/240V <br />Gen. Purpose Oullets(First 10 KVA) <br />97200 <br />2800 <br />10000.0 <br />100 <br />100000 <br />TAPS'. 2@2.5%FCAN <br />WINDINGS'. MANUFACTURER'S <br />Gen. Purpose Outlets(RemaindeO <br />0.0 <br />1340.0 <br />1340.0 <br />0.50 <br />670.0 <br />492.5%FCBN <br />STANDARD <br />Special Purpose Outlets <br />0.0 <br />0.0 <br />0.0 <br />1.00 <br />0.0 <br />Mechanical Equipment <br />00 <br />0.0 <br />0.0 <br />1.00 <br />0.0 <br />COOLING. CA <br />SPECIAL PROVISIONS. <br />Kitchen Equipment & Appliances <br />0.0 <br />0.0 <br />0.0 <br />1.00 <br />0.0 <br />Miscellaneous <br />0.0 <br />0.0 <br />0.0 <br />1.00 <br />0.0 <br />INSULATION: CLASS 220 <br />ELECTROSTATIC SHIELD <br />25%Largest Motor <br />0.0 <br />DEPT. OF ENERGYCOMPLIANT <br />TOTAL LOAD <br />12796.0 <br />1620.0 <br />14416.0 <br />14515.0 <br />TEMP. RISE'. 150C(40C AMBIENT) <br />TOTALAMPS(PRIMARV) <br />26.7 <br />34 <br />30.0 <br />30.2 <br />TOTALAMPS (SECONDARY) <br />53.3 <br />68 <br />60A <br />60.5 <br />EXISTING PANEL 2N2S (NORMAL BRANCH) <br />(NEW WORK) <br />SECOND FLOOR <br />VOLTAGE: 12011 PH 3W <br />TYPE: PANELBOARD <br />ENCLOSURE: NEMA1 <br />MOUNTING: SURFACE <br />FEED ER/BRANCH CIRCUIT DEVICES: <br />BOLT -ON CIRCUIT BREAKERS <br />FULLAIC RATING '. 10,000A <br />SERIES AIC RATING: 22,000A <br />ELECTRICAL LOAD <br />CALCULATION <br />CONNN <br />EXIST. <br />LOAD <br />NEW <br />A <br />TOTAL <br />DEMAND <br />FACTOR <br />DEMAND <br />LOAD IVA) <br />Lighting <br />Gen. Pupose Outlets(First 10 KVA) <br />Gen. Purpose CIE.(Remarder) <br />Special Purpose Outlets <br />Mechanical Equipment <br />Kitchen Equipment &Appliances <br />Miscellaneous <br />25%Largest Motor <br />3076.0 <br />97200 <br />00 <br />0.0 <br />0.0 <br />00 <br />00 <br />0.0 <br />2800 <br />13400 <br />0.0 <br />0.0 <br />00 <br />00 <br />3076.0 <br />100000 <br />13400 <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />1.25 <br />100 <br />050 <br />1.00 <br />1.00 <br />1.00 <br />1.00 <br />3845.0 <br />100000 <br />6700 <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />BUSSING'. MANUFACTURER'S STANDAR <br />CONTINUOUS RATING: 225 A <br />FULLAll RATING. 22,000A <br />SERIESAICRATING. NONE <br />SPECIAL PROVISIONS: <br />MASTER NAMEPLATE <br />GROUND BAR <br />SUITABLE FOR USE AS <br />ENTRANCE EQUIPMENT <br />SERVICE <br />MAIN: CIRCUIT BREAKER <br />CONTIN UOUS RATING. 150 A <br />FULLAICRATING: 22,000A <br />SERIESAICRATING'. NONE <br />LOCATION. BOTTOM <br />TOTAL LOAD <br />TOTAL AMPS <br />127:6.0 <br />33 <br />1620.0 <br />68 <br />14416.0 <br />60.1 <br />14515.0 <br />605 <br />CONN <br />LOAD A <br />FEEDER/BRANCHCIRCUIT <br />DESCRIPTION NrnE <br />BKR <br />AMP/P <br />CKT <br />NO <br />BUS <br />PHASE <br />CKT <br />NO <br />BKR <br />AMP/P <br />FEEDER/BRANCHCIRCUIT <br />DESCRIPTION <br />NOTE <br />CONN. <br />LOAD VA <br />180.0 <br />OUTLETS - HALL (1) <br />2011 <br />1 <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />2 <br />2011 <br />OUTLETS - THERAPY <br />M <br />540.0 <br />360.0 <br />OUTLETS - HALL (1) <br />2011 <br />3 <br />4 <br />20/1 <br />OUTLETS - THERAPY M <br />360.0 <br />180.0 <br />OUTLETSHALL1 <br />2011 <br />5 <br />6 <br />2011 <br />OUTLETS -THERAPY 1 <br />360.0 <br />7200. <br />OUTLETS- CONSULT, OFFICE, BREAK <br />2011 <br />7 <br />8 <br />_2V <br />OUTLETS - WAITING, CONSULT <br />540.0 <br />1260.0 <br />OUTLETS- CONSULT, OFFICE, BREAK, THERAPY <br />2011 <br />9 <br />10 <br />20/1 <br />OUTLETS - HALL. CONSULT <br />720.0 <br />7200. <br />OUTLETS-CONSULT, OFFICE,THERAPY <br />2011 <br />11 <br />12 <br />20/1 <br />OUTLETS - WAITING, CONSULT <br />1080.0 <br />10800 <br />OUTLETS -RECEPTION <br />2011 <br />13 <br />14 <br />2011 <br />OUTLETS -WORKROOM <br />3600 <br />540.0 <br />OUTLETS -RECEPTION <br />20/1 <br />15 <br />16 <br />20/1 <br />OUTLETS- CONSULT, WORKROOM <br />720.0 <br />180.0 <br />OUTLETS- NOURISHMENT COUNTER <br />2W <br />17 <br />18 <br />20/1 <br />OUTLETS TOILET, CONSULT <br />720.0 <br />180.0 <br />OUTLETS- NOURISHMENT COUNTER <br />20/1 <br />19 <br />20 <br />20/1 <br />SPARE <br />0.0 <br />1800 <br />OUTLETS-NOURISHMENTCOUNTER <br />20/1 <br />21 <br />22 <br />2011 <br />SPARE <br />00 <br />180.0 <br />OUTLETS -NOURISHMENT COUNTER <br />2011 <br />23 <br />24 <br />20/1 <br />SPARE <br />6.0 <br />180.0 <br />OUTLETS- U.C. REFRIGERATOR <br />2011 <br />25 <br />26 <br />2011 <br />SPARE <br />0.0 <br />0.0 <br />SPARE <br />2011 <br />27 <br />28 <br />20/1 <br />LTG- BEHAVIORAL HEALTH 1 <br />1286.0 <br />0.0 <br />SPARE <br />20/1 <br />29 <br />30 <br />20/1 <br />LTG- BEHAVIORAL HEALTH 1 <br />814.0 <br />0.0 <br />SPACE <br />31 <br />32 <br />20/1 <br />SPARE <br />0.0 <br />00 <br />SPACE <br />33 <br />34 <br />2011 <br />SPARE <br />00 <br />00 <br />SPACE <br />35 <br />36 <br />2011 <br />SPARE <br />00 <br />0.0 <br />SPACE <br />37 <br />38 <br />20/1 <br />LIFES <br />488.0 <br />0.0 <br />SPACE <br />39 <br />40 <br />20/1 <br />LIFES <br />488.0 <br />00 <br />SPACE <br />41 <br />42 <br />2011 <br />SPARE <br />00 <br />MAIN CIRCUIT BREAKER <br />NOTES: <br />(1) MODIFIED EXISTING CIRCUIT ON EXISTING CIRCUIT BREAKER <br />(2) NEW CIRCUIT CONNECTED TO EXISTING SPARE CIRCUIT BREAKER. <br />(3) ALL OTHER CI <br />RCUIFS ARE EXISTING TO REMAIN. <br />(4) EXISTING LOADS ARE CALCULATED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND VERIFIED BY FIELD OBSERVATION. <br />(5) THE WORK IN THIS PROJECT RESULTS INA NET LOAD DECREASE TO THIS PANEL. THEREFORE NO UPSTREAM LOADS ARE CALCULATED. <br />EXISTING PANEL 4N1 (NORMAL BRANCH) (EXISTING CONDITIONS) <br />FIRST FLOOR <br />VOLTAGE: 480Y/277V, 3 PH, 4 W <br />TYPE: PANELBOARD <br />ENCLOSURE. NEMA1 <br />MOUNTING: SURFACE <br />FEEDERIBRANCH CIRCUITDEVICES: <br />BOLT -ON CIRCUIT BREAKERS <br />FULLAICRATING. 14,000A <br />SERIES AIC RATING: 65,n00A <br />ELECTRICAL LOAD <br />CALCULATION <br />CONN.LOAD <br />EXIST. <br />NEW <br />VA <br />TOTAL <br />DEMAND <br />FACTOR <br />DEMAND <br />LOAD VA <br />Lighting <br />Gen. Puose Outets(FmNtl0 KVA) <br />Hurt, <br />Gen. Purpose Outlets(Remainder) <br />Special Purpose Outlets <br />Mechanical Equipment <br />Kitchen Equipment & Appliances <br />Miscellaneous <br />25%Largest Molar <br />14234.0 <br />1n0000 <br />1520.0 <br />0.0 <br />00 <br />0.0 <br />00 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />14234.01 <br />100000 <br />1520.0 <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />1.25 <br />100 <br />0.50 <br />1.00 <br />100 <br />1.00 <br />1.00 <br />17792.5 <br />100000 <br />760.0 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />0.0 <br />BUSSING'. MANUFACTURER'S STANDAR <br />CONTINUOUS RATING: 225 A <br />FULLAICRATING: 85,000A <br />SERIESAICRATING'. NONE <br />SPECIAL PROVISIONS: <br />MASTER NAMEPLATE <br />GROUND BAR <br />MAIN: LUGS ONLY <br />LOCATION. BOTTOM <br />TOTAL LOAD <br />TOTALAMPS <br />25754.0 <br />310 <br />0.0 <br />00 <br />25754.0 <br />310 <br />28552.5 <br />343 <br />CONN. <br />LOAD A <br />FEEDER/BRANCHCIRCUIT <br />DESCRIPTION <br />BKR <br />AMP/P <br />CKT <br />NO <br />BUS <br />toHASE <br />CKT <br />NO <br />BKR <br />AMP/P <br />FEEDER/BRANCH CIRCUIT <br />DESCRIPTION s <br />CONN. <br />LOAD VA <br />709.0 <br />LTG- CORRIDOR2ND FLOOR <br />20/1 <br />1 <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />A <br />B <br />C <br />2 <br />20/1 <br />LTG - SURGERY HALLWAY <br />1376.0 <br />12040 <br />LTG- CORRIDOR 2ND FLOOR NORTH <br />20/1 <br />3 <br />4 <br />20/1 <br />LTG- OFFICES/DR LOUNGE <br />5180 <br />7082.0 <br />7534.0 <br />PANEL 2N2S-SECOND FLOOR <br />70/2 <br />1 <br />5 <br />7 <br />6 <br />20/1 <br />LTG- STAFF LOUNGE/STOR <br />344.0 <br />8 <br />20/1 <br />LTG - SURGERY HALLWAY <br />1505.0 <br />00 <br />SPACE <br />9 <br />10 <br />20/1 <br />LTG-STERILECORE <br />8600 <br />0.0 <br />SPACE <br />11 <br />12 <br />20/1 <br />LTG- SURGERYCENTRAL AREA <br />1720.0 <br />0.0 <br />SPACE <br />13 <br />14 <br />20/1 <br />LTG-HOLD/CORR./LOBBV <br />1204.0 <br />00 <br />SPACE <br />15 <br />16 <br />20/1 <br />LTG-OFFICE/ADMIN/WAIFING <br />10750 <br />0.0 <br />SPACE <br />17 <br />18 <br />20/1 <br />LTG - MAIN LOBBY <br />645.0 <br />0.0 <br />SPACE <br />19 <br />20 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />21 <br />22 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />23 <br />24 <br />SPACE <br />0.0 <br />00 <br />SPACE <br />25 <br />26 <br />SPACE <br />00 <br />0.0 <br />SPACE <br />27 <br />28 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />29 <br />30 <br />SPACE <br />0.0 <br />00 <br />SPACE <br />31 <br />32 <br />SPACE <br />0.0 <br />00 <br />SPACE <br />33 <br />34 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />35 <br />36 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />37 <br />38 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />39 <br />40 <br />SPACE <br />0.0 <br />0.0 <br />SPACE <br />41 <br />42 <br />SPACE <br />0.0 <br />MAIN LUGS <br />EXISTING PANEL 2N2S (NORMAL BRANCH) <br />(EXISTING CONDITIONS) <br />SECOND FLOOR <br />VOLTAGE: 120240V,I PH, 3W <br />TYPE: PANELBOARD <br />ENCLOSURE: NEMA1 <br />MOUNTING. SURFACE <br />FEEDERNBRANCH CIRCUIT DEVICES: <br />BOLT -ON CIRCUIT BREAKERS <br />FULLAICRATING'. 10,000A <br />SERIES All RATING. 22,000A <br />ELECTRICAL LOAD <br />CALCULATION <br />CONN. <br />EXIST, <br />LOAD <br />NEW <br />VA <br />I TOTAL <br />DEMAND <br />FACTOR <br />DEMAND <br />LOAD VA <br />Lighting <br />Gen Purpose Outlels(Firsi KVA) <br />Gen Puryose0utlels(Remainder) <br />Special Purpose Outlets <br />Mechanical Equipment <br />Kitchen Equipment & Appliances <br />Miscellaneous <br />25%Largest Motor <br />30760 <br />10000.0 <br />15200 <br />00 <br />0.0 <br />00 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />30760 <br />10000.0 <br />1520.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />125 <br />1.00 <br />0.50 <br />1.00 <br />1.00 <br />100 <br />1.00 <br />38450 <br />10000.0 <br />760.0 <br />0.0 <br />0.0 <br />00 <br />0.0 <br />0.0 <br />BUSSING'. MANUFACTURER'S STANDARL <br />CONTINUOUS RATING. 225 A <br />FULLAICRATING: 22,000A <br />SERIESAICRATING'. NONE <br />SPECIAL PROVISIONS: <br />MASTER NAMEPLATE <br />GROUND BAR <br />SUITABLE FOR USE AS SERVICE <br />ENTRANCE EQUIPMENT <br />MAIN: CIRCUIFBREAKER <br />CONTINUOUS RATING: 150 A <br />FULLAICRATING: 22,000A <br />SERIES All RATING. NONE <br />LOCATION'. BOTTOM <br />TOTALLOAD <br />TOTALAMPS <br />14596.0 <br />608 <br />0.0 <br />00 <br />14598.0 <br />608 <br />14605.0 <br />609 <br />CONN. <br />LOAD A <br />FEEDER/BRANCH CIRCUIT <br />DESCRIPTION <br />BKR <br />AMP/P <br />CKT <br />N <br />BUS <br />toHASE) <br />CKT <br />BKR <br />MP/P <br />FEEDER/BRANCH CIRCUIT <br />DESCRIPTION <br />` <br />CONN. <br />LOAD VA <br />180.0 <br />OUTLETS - CONTROL ROOM 215 <br />20A <br />1 <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />B <br />A <br />2 <br />20/1 <br />OUTLETS - CONTROL ROOM 215 <br />360.0 <br />00 <br />SPARE <br />2011 <br />3 <br />4 <br />2011 <br />OUTLETS - ROOM 4 <br />3600 <br />180.0 <br />OUTLETS -CONTROL ROOM 215 <br />20M <br />5 <br />6 <br />20/1 <br />OUTLETS -ROOM 4, WAITING <br />360.0 <br />900.0 <br />OUTLETS - ROOMS 1, 2, 3 <br />2011 <br />7 <br />8 <br />20/1 <br />OUTLETS - WAITING <br />540.0 <br />1260.0 <br />OUTLETS - ROOMS 12,3 <br />20M <br />9 <br />10 <br />20/1 <br />OUTLETS - COPIER <br />720.0 <br />12600 <br />OUTLETS - ROOMS 123 <br />2011 <br />11 <br />12 <br />20/1 <br />OUTLETS - FILE AREA <br />10800 <br />1080.0 <br />OUTLETS - RECEPTION <br />20M <br />13 <br />14 <br />20/1 <br />OUTLETS -ROOM 5, BATHROOM <br />360.0 <br />54M <br />OUTLETSRECEPTION20/1 <br />15 <br />16 <br />20/1 <br />OUTLETS- FILE AREA 203 SLEEP ROOM 218 <br />720.0 <br />1800 <br />OUTLETS -KITCHEN <br />2011 <br />17 <br />18 <br />20/1 <br />OUTLETS- TOILET 217, SLEEP ROOM 218 <br />7200 <br />180.0 <br />OUTLET -TOASTER <br />20M <br />19 <br />20 <br />20/1 <br />SPARE <br />0.0 <br />180.0 <br />OUTLETPOPCORN2011 <br />21 <br />22 <br />20/1 <br />SPARE <br />0.0 <br />180.0 <br />OUTLETS - MICROWAVE <br />20A <br />23 <br />24 <br />20/1 <br />SPARE <br />0.0 <br />180.0 <br />OUTLETS- U.C. REFRIGERATOR <br />20M <br />25 <br />26 <br />20/1 <br />SPARE <br />0.0 <br />0.0 <br />SPARE <br />20M <br />27 <br />28 <br />20/1 <br />LTG - SLEEP LAB <br />1288.0 <br />0.0 <br />SPARE <br />20/1 <br />29 <br />30 <br />20/1 <br />LTGSLEEPLAB <br />814.0 <br />00 <br />SPACE <br />31 <br />32 <br />2011 <br />SPARE <br />0.0 <br />0.0 <br />SPACE <br />33 <br />34 <br />20/1 <br />SPARE <br />0.0 <br />0.0 <br />SPACE <br />35 <br />36 <br />2011 <br />SPARE <br />0.0 <br />0.0 <br />SPACE <br />37 <br />38 <br />20/1 <br />LIrES <br />488.0 <br />0.0 <br />SPACE <br />39 <br />40 <br />20/1 <br />LIFES <br />488.0 <br />00 <br />SPACE <br />41 <br />42 <br />20/1 <br />SPARE <br />00 <br />MAIN CIRCUIT BREAKER <br />2727 Oakes Ave. <br />Suite 100 <br />Everett, WA 98201 <br />REVISIONS <br />R. <br />,EA <br />v1P� <br />0 <br />5N <br />0 M794 <br />�' F'1018TIi4�' ti� <br />2ONAL <br />E�yG <br />U - <br />�� <br />.0 CIO <br />CIO •> <br />A <br />(L <br />U N _ <br />^1 I <br />O <br />•> O Q <br />O O O <br />IL LL CL <br />III N. 2375 <br />n- Err KL <br />-nit er SO <br />CONSTRUCTION SET <br />12-17-2024 <br />ELECTRICAL - <br />PANEL <br />SCHEDULES <br />E 6.3 <br />City of Everett Permit Services <br />EVERETT Reviewed for Permit 01/14/2025 <br />