My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 2ND FLOOR 2025-06-30
>
Address Records
>
PACIFIC AVE
>
916
>
2ND FLOOR
>
916 PACIFIC AVE 2ND FLOOR 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:39:19 PM
Creation date
5/2/2025 1:34:44 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application <br />Testing & Maintenance <br />The SIGA-OSD detects particles from a wide range of combustion <br />sources and will trigger an alarm when smoke density in the <br />chamber reaches preprogrammed level. Thanks to its high- <br />performance reflective response technology, the smoke sensor <br />responds quickly and reliably to a wide range of fire types, <br />including both fast and slow burning fires fueled by combustibles <br />typically found in modern multi -use buildings. <br />Compatibility <br />The SIGA-OSD detector is compatible only with control panels <br />using a Signature Loop controller. <br />Installation <br />Signature Series detectors mount <br />to North American 1-gang boxes, <br />3-1/2 inch or 4 inch octagon <br />o 0 <br />boxes, and to 4 inch square <br />Self-locking tab <br />electrical boxes 1-1/2 inches <br />(38 mm) deep. They mount to <br />European BESA and 1-gang <br />boxes with 60.3 mm fixing <br />LED Indicator <br />centers. See mounting base <br />installation and wiring for <br />more information. <br />Sensing and reporting technology <br />The microprocessor in each detector provides additional <br />benefits — Self -diagnostics and History Log, Automatic Device <br />Mapping, and Fast, Stable Communication. <br />Self -diagnostics and History Log - Each Signature Series <br />detector constantly runs self -checks to provide important <br />maintenance information. The results of the self -check are <br />automatically updated and permanently stored in the detector's <br />non-volatile memory <br />Automatic Device Mapping - The loop controller learns where <br />each device's serial number address is installed relative to other <br />devices on the circuit. The mapping feature provides supervision <br />of each device's installed location to prevent a detector from being <br />reinstalled (after cleaning, etc.) in a different location from where it <br />was originally. <br />Fast Stable Communication - On -board intelligence means <br />less information needs to be sent between the detector and the <br />loop controller. Other than regular supervisory polling response, <br />the detector only needs to communicate with the loop controller <br />when it has something new to report. <br />Each detector automatically identifies when it is dirty or defective <br />and causes a "dirty detector" message. The detector's sensitivity <br />measurement can also be transmitted to the loop controller. <br />A sensitivity report may be printed to satisfy NFPA sensitivity <br />measurements, which must be conducted at the end of the first <br />year and every two years thereafter. <br />The user-friendly maintenance program shows the current state <br />of each detector and other pertinent messages. Single detectors <br />may be turned off temporarily from the control panel. Availability of <br />maintenance features is dependent on the fire alarm system used. <br />Accessories <br />Detector mounting bases have wiring terminals that are <br />accessible from the "room -side" after mounting the base to the <br />electrical box. The bases mount to North American 1-gang boxes <br />and to 3'/2 inch or 4 inch octagon boxes, 1 t/2 inches (38 mm) <br />deep. They also mount to European BESA and 1-gang boxes with <br />60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-I134 <br />mount to North American 4 inch sq. electrical boxes in addition to <br />the above boxes. They include the SIGA-TS4 Trim Skirt, which is <br />used to cover the "mounting ears" on the base. The SIGA-AB4G <br />mounts to a 4 inch square box only. <br />I <br />SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED <br />Audible Base Standard Base Isolator Base Relay Base Remote LED <br />Remote LED SIGA-LED - The remote LED connects to the <br />SIGA-SB or SIGA-SB4 Standard Base only. It features a North <br />American size 1-gang plastic faceplate with a white finish and <br />red alarm LED. <br />SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also <br />be ordered separately to use with the other bases to help hide <br />surface imperfections not covered by the smaller bases. <br />Sounder Bases - Signature Series sounder bases are designed <br />for use where localized or group alarm signaling is required. <br />• SIGA-AB4G bases provide sounder capability to Signature <br />Series to heat and smoke detectors. They are not intended <br />for use with combination carbon monoxide detectors in <br />Fire -plus -CO mode. <br />• SIGA-AB4GT bases provide sounder capability to Signature <br />Series smoke and heat detectors, as well as carbon <br />monoxide detectors when used with a SIGA-TCDR Temporal <br />Pattern Generator. <br />• SIGA-AB4G-LF bases provide 520 Hz low frequency <br />sounder capability to Signature Series smoke and heat <br />detectors, as well as carbon monoxide detectors when <br />used with a SIGA-TCDR Temporal Pattern Generator. The <br />SIGA-AB4G-LF is suitable for applications requiring low <br />frequency audible tones. <br />Page 2 of 4 <br />DATA S H E EE85001-1001 <br />Not to be used for installati ,oses. Issue 1.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.