My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 2ND FLOOR 2025-06-30
>
Address Records
>
PACIFIC AVE
>
916
>
2ND FLOOR
>
916 PACIFIC AVE 2ND FLOOR 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:39:19 PM
Creation date
5/2/2025 1:34:44 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br />The detector mounting bases accept #18 AWG (0.75mm2), #16 <br />(1.0mm2), 414 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. <br />Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred <br />for ease of installation. <br />Standard Detector Base, SIGA-SB, SIGA-SB4 <br />This is the basic mounting <br />base for EDWARDS Signature <br />Series detectors. The SIGA- <br />LED Remote LED is supported <br />by this Base. <br />Term Description <br />1 Not Used <br />2 DATA IN/OUT (+) <br />3 Not Used <br />4 DATA IN (-) <br />4 Remote LED (-) <br />5 Remote LED (+) <br />6 Not Used <br />7 DATA OUT (-) <br />Remote LED <br />Max resistance <br />per wire <br />+ must not exceed <br />10 Ohms <br />O 6 6� <br />O <br />)ATA IN (-) O z o O DATA OUT 1-) <br />DATA IN (+) DATA OUT (+) <br />From Signature Controller To Next Device <br />or Previous Device <br />Isolator Detector Base, SIGA-IB, SIGA-1134 <br />This base includes a built-in line fault isolator for use on Class A <br />circuits. A detector must be installed for it to operate. The isolator <br />base does not support the SIGA-LED Remote LED. <br />The isolator operates as follows- <br />- a short on the line causes all <br />isolators to open within 23 n <br />- at 10 msec intervals, beginni <br />on one side of the Class A <br />circuit nearest the loop <br />controller, the isolators DA] <br />close to provide the <br />next isolator down DATA IN (+) <br />the line with power. From Signature Controller <br />or Previous Device <br />- when the isolator next <br />to the short closes, it <br />reopens within 10 msec. <br />The process repeats beginning on <br />the other side of the loop controller. <br />Relay Detector Base, SIGA-RB, SIGA-RB4 <br />This base includes a relay. <br />Normally Open or Normally <br />Closed operation is selected <br />during installation. The dry <br />contact is rated for 1 amp <br />(pilot duty) @ 30 Vdc. The <br />relay's position is supervised <br />to avoid accidentally jarring it <br />out of position. The SIGA-RB <br />can be operated as a control <br />relay if programmed to do so <br />at the control panel. The relay <br />base does not support the <br />SIGA-LED Remote LED. <br />DAT, <br />Audible Sounder Bases, Fire Mode <br />AB4GT1 A134G, A134G-LF sounder bases <br />SIGA-AB4GT, <br />SIGA-AB4G, <br />SIGA-AB4G-LF: <br />Volume Setting <br />Default = High <br />Cut/remove <br />jumper for <br />low dB <br />24 Vdc in <br />From power supply <br />or previous base + <br />Data in _ <br />From Signature Controller <br />or previous device + <br />Jumper cuts <br />DATA. DATA. DATA+ <br />SIG+ SIG- OUT IN IN/ON <br />Warnings & Cautions <br />SIGA-AB4G-LF: <br />Output Mode <br />Default = Fire <br />Cut/remove jumper <br />for Fire plus CO <br />SIGA-AB4G: <br />Tone Setting <br />Default = Temporal <br />Cut/remove jumper <br />for Steady <br />- 24 Vdc out <br />+ To next base or EOL relay <br />Data out <br />to next Signature device <br />This detector does not operate without electrical power. <br />As fires frequently cause power interruption, discuss <br />further safeguards with the local fire protection specialist. <br />• This detector does not sense fires in areas where smoke <br />cannot reach the detector. Smoke from fires in walls, <br />OUT (-) roofs, or on the opposite side of closed doors may not <br />reach the detector. <br />DATA OUT (+) <br />To Next Device <br />Term Description <br />1 Not Used <br />2 DATA IN/OUT (+) <br />3 DATA IN (-) <br />4 Not Used <br />5 Not Used <br />6 DATA OUT (-) <br />7 Not Used <br />Normally- Normally- <br />Iry �T� <br />From Signature Controller <br />To Next Device <br />or Previous Device <br />Term Description <br />1 <br />Normally Open <br />CONTACT RATING <br />2 <br />DATA IN/OUT (+) <br />1.0 Amp @ 30 VDC <br />3 <br />Common <br />(Pilot Duty) <br />4 <br />5 <br />6 <br />7 <br />DATA IN (-) <br />Not Used <br />Normally -Closed <br />DATA OUT (-) <br />• In Canada, install according to CAN/ULC-S524 Standard for <br />the Installation of Fire Alarm Systems, CSA C22.1 Canadian <br />Electrical Code, and the local authority having jurisdiction. <br />Page 3 of 4 DATA SHEET E85001-1001 <br />Not to be used for installation purposes. Issue 1.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.