1903 JACKSON AVE A, B 2025-10-24
>
Address Records
>
JACKSON AVE
>
1903
>
1903 JACKSON AVE A, B 2025-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2025 8:49:31 AM
Creation date
5/6/2025 11:08:51 AM
Metadata
Fields
Template:
Address Document
Street Name
JACKSON AVE
Street Number
1903
Unit
A, B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEMBER REPORT <br />MAIN, M13#10 COL <br />1 piece(s) 6 x 6 HF No.2 <br />PASSED <br />Post Height: 8' <br />'tlt5i • ti`.RESUIts �. -° ' ' <br />'C;lutpal I�' � <br />r�iUtuwed 'v <br />itesuib;? .. ; <br />i.Ui? <br />load Combtnb>�(on ; " _._... �,, � � <br />Slenderness <br />17 <br />50 <br />Passed,(35%) <br />-- <br />Compression-(lbs) <br />6716 <br />14894 <br />Passed (45%) <br />1.00 <br />1.0 D + 1.0 L <br />Base Bearing (Ibs) <br />6716 <br />898425 <br />Passed (1%) <br />1.0 D + 1.0 L <br />Bending/Compression <br />0.71 <br />1 <br />Passed (71%) <br />1.00 <br />1.0 D + 1.0 L <br />• input axial ioad eccentricity for cols design Is 15.67 % of applicable member side dimension. <br />• Applicable calculations are based on NDS. <br />.. `qda TY MONttf Member Type :Free Standing Post <br />Base Plate Steel Building Code : IBC 2018 <br />Design Methodology : ASD <br />i±�aseti�tlbrac�d 1:eIS t(4 M Com�tonps .. .... m_... <br />Full Member Length No bracing assumed. <br />Drawing is Conceptual <br />�'< <br />OCad, ` <br />Floortivo.�° <br />R'Daff.Iv£ <br />'Snd+vm <br />00) <br />(x as) <br />" zC {� �sl, <br />i <br />.. <br />ccmmnis <br />1- Point (lb) <br />2615 <br />4101 <br />104E <br />1308 <br />Linked from: M13#10, Support 1 <br />Weyerhaeuser warrants that the sWng of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by Itx-ES under evaluation reports ESR 1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/dowment-library. <br />The product application, Input design loads, dimensions and support Information have been provided by ForteWEB Software Operator <br />FotteWEB Software Operator Job Notes <br />Chris Lalonde <br />Structural Design Associates <br />(425) 339-0293 <br />daoonde@sdaeverett.com Weyeufiaeuser <br />2/15/2024 7:49:39 PM UTC <br />ForteWEB 0.7, Engine: V8.4.0.40, Data: V8.1.5.0 <br />Fiie Name: 9902 <br />