Laserfiche WebLink
DIFFUSERS, GRILLES AND REGISTERS <br /> A <br /> B IR <br /> MARK SERVICE LOCATION CEILING TYPE MOUNTING TYPE MANUFACTURER MODEL NUMBER REMARKS DIA. WIRE DIA. ROD STRAP A/R <br /> p 15'OR LESS 0�B I/�I n�W 15'OR LESS ILL /oJL� <br /> D-1 SUPPLY CEILING GYP. BOARD LAY-IN TITUS TOO XX 9X9 12X12 3 26 4 D-75 1-3,5 10"DIN ONE 12 GA. 1/4" 1" x 22 GA. v �,- r` <br /> D-2 SUPPLY CEILING GYP. BOARD LAY-IN PTUS TOO XX 18X18 24X24 3 26 4 D-75 (1-3,5 11-18" TWO 12 GA. OR ONE 8 GA. 1/4" 1" x 22 GA. <br /> TRANSFORMATION EXPANSION CONTRACTION <br /> D-3 SUPPLY CEILING GYP. BOARD SURFACE TITUS FL20 2 77 HT FBP120 2 12" 1-5 19-24'" TWO 10 GA. 1/4" 1" x 22 GA. <br /> G-1 RETURN CEILING GYP. BOARD SURFACE TITUS 350RL X X X 1 26 1,2,5 25-36" TWO 8 GA. 3/8" 1" x 20 GA. <br /> REMARKS 37-50" - TWO 3/8" TWO 1" x 20 GA. 1URNIW 1. TITUS IS THE BASE OF DESIGN. KRUEGER, PRICE, NAILOR, CARNES ARE EQUAL. NO EXCEPTIONS. <br /> verve <br /> 2. SEE PLAN FOR - -NECK SIZE 51 60" TWO 3/8" TWO 1" x 18 GA.3. PROVIDE WITH MODEL TRM FRAME. 61-84" - TWO 3/8" TWO 1" x 16 GA. 7URNING 4. 1. ©2023 STARBUCKSCOFFEECD- <br /> EE PLAN FOR LENGTH PROVIDE WITH INSULATED PLENUM RB INDICATED. MANAGER 85-96" - TWO 1/2" TWO 1 1/2" x 16 GA. vANEs I5. COORDINATE FINAL PAINT COLOWlhi ARCHITECT ANDSTARBUCKS PROJECT,,,'I .! NOTES: n�REESTARBU KIL VANES <br /> III 1. STRAPS ARE GALVANIZED STEEL; RODS ARE UNCOATED OR 90'ELBOW ° 2835 N MCCARRAN BLVD#103 <br /> AIR SOURCE HEAT PUMPS GALVANIZED STEEL; WIRE IARE S BLACK ANNEALED, BRIGHT BASIC OR <br /> GALVAN I ZED STEEL. ALL 45' ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS SPARKS,NEVADA89431 <br /> ELECTRICAL ALTERNATIVES. <br /> NOMINAL HEATING 2. TABLE ALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT (775)331-8551 <br /> MARK LOCATION SERVES COOL AT 47F SEER2 HSPF2 MANUFACTURER MODEL NUMBER REMARKS II SYSTEMS PLUS ONE LB/SF OF INSULATION WEIGHT. IF HEAVIER <br /> (TONS) (MBH) VOLT PH MCA MOCP /EER /COP i, DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THESE DRAWINGS AND THE PROJECT MANUAL <br /> THEIR LOAD LIMITS. ARE CONIF SOLEI DENTPROPIL AND SHALL ERTY OF STARBUCKS N THE <br /> ASHP-1 ROOF AHU-1 4 4.0 208 1 26.0 40 14.6 - 7.8 - TRANE 4TWR4048N1 1-4 <br /> REMARKS: ROUND DUCT ./ c RT CORPORATION,WHICH IS THE OWNER OF THE <br /> COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> 1. PROVIDE EQUIPMENT WITH SCCR GREATER THAN THE AVAILABLE FAULT CURRENT AT THE EQUIPMENT OR UPSTREAM PANELBOARD. i•, BE REPRODUCED(IN WHOLE OR IN PART), <br /> REFER TO THE ELECTRICAL ONE LINE DIAGRAM AND PANEL SCHEDULES FOR AVAILABLE FAULT CURRENT AT UPSTREAM PANELBOARD. i��� 6 HANGER TABLE ; SHARED WITH THIRD PARTIES OR USED IN ANY <br /> 2. PROVIDE LOW AMBIENT CONTROL. iIi SUPPLY OR RETURN WYE TURN/NG VANES MANNER ON OTHER PROJECTS OR <br /> 3. PROVIDE HAIL GUARD. (RECTANGULAR DUCT) �-= EXTENSIONS TOTH IS PROJECT WITHOUT THE <br /> 4. PROVIDE CORROSION PROTECTION. NOT TO SCALE PRIOR WRITTEN CONSENT OF STARBUCKS <br /> /o CORPORATION.THESE DRAWINGS AND <br /> ''ilf 3 p SPEDES GAN INTENTTIONS RFORTA PROTOTYENDED TO P CALESS <br /> FAN COIL UNITS II Qo STARBUCKS STORE(WHICH IS SUBJECT TO <br /> COOLING HEATING SUPPLY EXT. ELECTRICAL 25-1/4, 21-1/4", 19-1/4"OR - DI CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> MARK SEN TOT COOL AT ELEC AIR S.P. FAN WEIGHT SEER2 HSPF2 TRANE 13-1/4"OUTSIDE DIMENSION ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> MBH 47F HP VOLT PH MCA MOCP LBS) /EER COP MODEL NUMBER REMARKS "C"CHANNEL °-•I 3/4D 90'ELBOW TAKE-OFF SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> ( ) (MBH) (TON) (MBH) (KW) (CFM) (IN) ( / II REINFORCING RETURN AIR BRANCH USE ONLY IN AREAS THEOTHER(EXCEPT STATED ABOVE UNTIL <br /> FULL RADIUS ELBOW ) <br /> AHU-1 37.2 48.8 4 44.0 - 1,600 0.60 0.75 208 1 9.0 15 174 14.6 -7.8 - TEM6AOC48H41 1-4 BY G.C. FITTING WHERE SPACE IS LIMITED TAKE-OFF WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> AROUND BOTH PARTIES. <br /> I" TRANE IS THE BASIS OF DESIGN. HIGH EFFICIENCY CARRIER, MAGIC AIRE, JOHNSON CONTROLS OR LENNOX ARE EQUAL, OPENING <br /> COOLING CAPACITIES ARE BASED ON AHRI STANDARD 210/240 OR 340/360: 80'F DB/67'F WE INDOOR ENTERING AIR STARBUCKS TEMPLATE VERSION:i2023.04.24 <br /> TEMPERATURE, 95-F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT MAY DIFFER FROM AHRI STANDARD CFM. DUCTWORK DETAILS <br /> REMARKS: d.\ <br /> 1. PROVIDE AUXILIARY DRAIN PAN. '' \ 3 ARCHITECT OF RECORD <br /> 2. PROVIDE HANGERS AND VIBRATION ISOLATION FOR SUSPENSION FROM STRUCTURE. �` <br /> MOUN77NG SCREW NOT TO SCALE <br /> 3. PROVIDE RETURN DUCT SMOKE DETECTOR. N F7ELD INSTALLED <br /> 23", 19", 17"OR 11" -,p <br /> 4. PROVIDE WATER LEVEL MONITORING DEVICE IN DRAIN PAN TO SHUT OFF UNIT IF THE DRAIN LINE BECOMES RESTRICTED `( INSIDE DIMENSION <br /> IIG <br /> il! \\ 7 DRYWALL CEILING <br /> 1 �91nIII .. ,J.' l Rll lllldlMl�I; IIIIh l <br /> u N 1-1/2" GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> SEAT TTH AVENUE,SUITE 700 <br /> SEATTLE,WA 9E101 <br /> (206)224-3335 <br /> �S0 <br /> i <br /> STEEL � <br /> NG 24', 20", 18"OR 12" 1.7/8 FRAME I O�� cpO Ctiifi <br /> c� • '�9CW <br /> MITE <br /> 1. CONTACT MANIFACTLIRER FOR INFORMATION 90 FIVE SEC 77ON 45 THREE SECTION <br /> REGARDING ROUGH-IN SIZES. ELBOW ELBOW afm <br /> TYPICAL DRYWALL ONAL OeO 70125123 <br /> MOUNTING FRAME DETAIL COA f Z609 <br /> J <br /> NOT TO SCALE 90 <br /> 45 <br /> El <br /> 90 BRANCH TAKE-OFF 45 BRANCH TAKE-OFF L N <br /> OTYPICAL ROUND DUCT FITTINGS 00 <br /> NOT TO SCALE eft Q <br /> W <br /> O L <br /> W L <br /> �jll,ialllallnll1plullil iii .ww i o��2nr Ii 1'. - a ,t AX. OF 12"TO BRANCH CONNEC770N r <br /> W <br /> sn <br /> UNLESS NOTED OTHERWNSE 2 p <br /> AIR DUCT------- GAL KANIZED SHEET METAL Z ¢ Z W <br /> DUCT AND INSULA RETURN TUBE 1 i PER SPECF/CA 77ONS N L) U <br /> TENANT CONDENSING UNIT O 0 LU O W <br /> / > <br /> MM <br /> d W d r W <br /> USE RIGID GAL VAN/ZED <br /> DUCT90 DEGREE ELBOW STORE#: 22$17 <br /> DE7F SMOKE i� PRO WDE PRO PAD <br /> DETECTOR ID =0- s <br /> UNDER BLOCKING/N iA METAL STRAP CLAMP a Q1 o m1 PROJECT#: 60007-039 <br /> ACCORDANCE W77H THE GAL✓AN/ZED SHEET METAL (TYPICAL)2 PLACES <br /> ROOFING MANUFACTURERS DUCT AND INSULATION m p ISSUE DATE: 10.2.2023 <br /> INSTRUCTION RE SPECIFlCA770N5 INSULATED FLEXIBLE DUCT o p�c DESIGN MANAGER: GRAPHITE <br /> RESTRAINED SPRING _ = j j (MIN. 2; MAX. 5; NO MORE A? m PRODUCTION DESIGNER: GRAPHITE <br /> WSRA 77ON ISOLATORS = / <br /> (PROVIDE SEISM/C SNUBBERS / VOLUME DAMPER LOCATED OPPOSED THAN ONE 90-BEND) mr m=z <br /> _ CHECKED BY: <br /> IN ACCESSIBLE LOCATION. BLADE DAMPER <br /> SAMPLING TUBE WHERE APPLICABLE �= x <br /> ) PROVIDE ACCESS DOOR OR AT DIFFU TRANSITION FITTING non <br /> CABLE OPERATOR/F NOT AS REQUIRED m Revision Schedule <br /> :ACCESSIBLE /NSULA 7F DIFFUSER n p>z <br /> BACK AND SEAL WJ7H SUPPL Y AIR DIFFUSER ro T o O Rev Date By Description <br /> NOTE 4x4 PRESSURE TREATED VAPOR BARRIER TAPE TYPE AS/NDICA 7ED A m m 3/182024 REV 1:HVAC REDESIGN <br /> I. DUCT SMOKE DETECTOR ON RETURN AND/OR SUPPLY SIDE DUCT AND SHUTDOWN RELAY1i:' BOARD BETWEEN ROOF AND m <br /> SHALL SE FURNISHED 8Y 77-I ON SCHEDULE mE ELECTRICAL CONTRACTOR FOR/NSTALLA 77ON BY THE III° CONDENSING UNIT SUPPORT ;_' z <br /> MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CON7RACTOR. <br /> DUCT SMOKE <br /> III. SHEET TITLE: <br /> DETECTOR DETAIL ;" 4CONSDENSING UNIT SUPPORT DETAIL MECHANICAL DETAILS <br /> TO <br /> TYPICAL DIFFUSER CONNECTION SCALE:AS SHOWN <br /> NOT TO SCALE C� <br /> R dVulp q III 7�1 � SHEET NUMBER: <br /> o <br /> M 501 <br />