My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
Plans
>
1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:12:03 PM
Creation date
5/7/2025 8:18:57 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Permit
B2311-026
Year
2023
Notes
TI EXISTING STARBUCKS CAFE, PARTITIONS, EQUIPT RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DUCT SHOULD EXTEND STRAIGHT MAXIMUM PAIR AT PAIR AT PAIR AT PAIR AT <br /> FOR SEWRAL INCHES FROM A HALF OF 10 FT. SPACING 8 FT. SPACING 5 FT. SPACING 4 FT. SPACING <br /> CONNEC770N BEFORE @END/N DUCT WIRE/ WIRE/ WIRE WIRE _PERIMETER STRAP ROD STRAP ROD STRAP ROD STRAP ROD <br /> Oro"T1 P 10 GA. 10 GA. 12 GA. 12 GA. <br /> Tj� (38mm) MINIMUM 2= 30" 1" z 22 GA. (,135") 1" x 22 GA. (,135") 1" x 22 GA. (,106") 1"x 22 GA. (.106") <br /> MUM O P= 72" 1" x 18 GA. 3/8' 1" x 20 GA. 1/4" 1" x 22 GA. 1/4" 1`x 22 GA. 1/4" <br /> 2 <br /> P= 96 1" x 16 GA. 3/8" 1" x 18 GA. VS" 1' x 20 GA. 3/8" 1"x 22 GA. 1/4" Qzoza eraseucxs com£muvnHr <br /> MAX. SAG 1/2-PER <br /> 2 <br /> FOOT(41.7 mm PER m) r 1 1/2"(38mm)BAND CLAMP P= 120" 1 1 / / / , S T A R B U C K <br /> WITH WRE IS OP77ONAL 2 /2' x 16 GA. 1 2` i" x 16 GA. 3 8' 1" z 18 GA. 3 8" 1" z 20 GA. 1 4" <br /> OF SUPPORT SPACING 2835 N MCCARRAN BLVD#103 <br /> P= 168" 1 1/2" x 16 GA. 1/2" 1 1/2" x 16 GA. 1/2" 1"x 16 GA. 3/8" 1" x 18 GA. 3/8' SPARKS,NEVADA89431 <br /> a o" 2 (775)331-8551 <br /> T7 P= 192" --- 1/2" 1 1/2" x 16 GA. 1/2" 1"x 16 GA. 3/8" 1" x 16 GA. 3/8" THESE DRAWINGS AND THE PROJECT MANUAL <br /> 2 ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> SOLE PROPERTY OF STARBUCKS <br /> UM RE P= 193"UP CORPORATION,WHICH IS THE OWNER OF THE <br /> MAX. SAO 1/2"PER 2 SPECIAL ANALYSIS REQUIRED COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> FOOT(41.7 mm PER m) BE REPRODUCED(IN WHOLE OR IN PART), <br /> OF SUPPORT SPACING WHEN STRAPS ARE LAP JOINED SINGLE HANGER MAXIMUM ALLOWABLE LOAD SNARED WITH THIRD PARTIES ORUSED IN ANY <br /> USE THESE MINIMUM FASTENERS: STRAP WIRE OR ROD DIA.) MANNER ON OTHER PROJECTS OR <br /> ( EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 6 �-1 1 2" 38mm MINIMUM 1" x 18, 20, 22 GA. — TWO#10 OR ONE 1/4" BOLT PRIOR WRITTEN CONSENT OF STARBUCKS <br /> / ( ) 1"x 22 GA.—260 LBS. 0.106"—80 LBS. CORPORATION.THESE DRAWINGS AND <br /> 1" x 16 GA. — TWO 1/4'DIA. 1"x 20 GA.—320 LBS. 0.135"-120 LBS. SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> CLOSER MAXIMUM INTERVALS MAY BE SPECIFIED 1" x 16 GA. — TWO 3/8" DIA. 1" x 18 GA.—420 LBS. 0.162"—160 LBS. DESIGN INTENT FOR A PROTOTYPICAL <br /> AS A CONDITION OF U.L. LISTING, PARTICULARLY PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE. 1" x 16 GA.—700 LBS. 1/4"—270 LBS. STARBUCKS STORE(WHICH IS SUBJECT TO <br /> IN FIRE RATED FLOOR— CEILING ASSEMBLIES 1 1/2'x 16 GA.—1100 LBS. 3/8"-680 LBS. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> ACTUAL CONDITIONS. <br /> 1/2"—1250 LBS. SHALLHAVE ANY OBLIGATION NOR LIABILIITTYTO <br /> 5/8"—2000 LBS. THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> 3/4"—3000 LBS. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> BOTH PARTIES. <br /> NOTES: <br /> 1. DIMENSIONS OTHER THAN GAUGE ARE IN INCHES. STARBUCKS TEMPLATE VERSION:12023.04.24 <br /> 2. TABLES ALLOW FOR DUCT WEIGHT, 1 LB./SF INSULATION WEIGHT AND NORMAL REINFORCEMENT <br /> � AND TRAPEZE WEIGHT, BUT NO EXTERNAL LOADS. ARCHITECT OF RECORD <br /> ��FLEXIBLE X I B LE DUCT SUPPORTS P P 0 R TS <br /> 3. STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL. <br /> J 4. ALLOWABLE LOADS FOR P/2 ASSUME THAT DUCTS ARE 16 GA. MAXIMUM, EXCEPT THAT WHEN <br /> NOT TO SCALE MAXIMUM DUCT DIMENSION (W) IS OVER 60" THEN P/2 MAXIMUM IS 1.25 W. <br /> 5. 12, 10 OR 8 GA. WIRE IS STEEL OF BLACK ANNEALED, BRIGHT BASIC OR GALVANIZED TYPE <br /> 6. DUCTS SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 10 FEET. <br /> GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> 1807 7TH AVENUE,SUITE 700 <br /> REFRIGERANT PIPING S/ZED PER THREADED ROD HANGER, CONNECT SEATTLE,WA 98101 <br /> MANUFACTURERS REQUIREMENTS TO S7RUCTURE AS REQUIRED (206)224-3335 <br /> FILTER ACCESS SHALL BE WBRA 770N ISOLATORS <br /> UNCB57RUC7ED FOR 7NE FULL <br /> CINCH BAND RWDTHEQUIRED <br /> OF BY UNIT OR AS SC HANDLING UNIT. REFER TO RECTANGULAR DUCT HANGER TABLE o� o s <br /> REQU/RED BY MANUFACTURER. SCHEDULES AND SPEC/f7CA770NS y C <br /> FOR S/ZES AND ADD/7/ONAL <br /> PROVIDE AUX/L/ARY IN PAN REQU/REM£N75 < C' <br /> DRAIN PAN SHALL EXTEND 6" NOT TO SCALE 3 y 4 m <br /> /NSULA TED BEYOND AIR HANDLING UNIT/N HEA 77NG COIL(IF APPLICABLE). r' <br /> INSULATED VII—SHEYT EACH DIREC77ON. PROVIDE REFER 70 SCHEDULES FOR <br /> METAL FLOAT SIMTCH IN DRAIN PAN ADD177ONAL INFORMA77ON AND Ae 31 <br /> FLEXIBLE PLENUM AND INTERLOCK FOR UNIT REQUIREMENTS <br /> DUCT SHUTDOWN. FLEXIBLE CONNEC770N HANGER STRAPS I ANGLE OR ROD—, ONAL �Oc"w pro <br /> PRIMARY CONDENSATE DRAIN PIPE <br /> METAL SIZE SHALL BE NO LESS THAN DRAIN SUPPLY AIR DUCT. REFER TO <br /> 57UD CONNEC770N ON UNIT. REFER 70 PLANS FOR 5/2ES AND <br /> ROUND 70 FRAMING SPECIFICATIONS FOR CONDENSATE SPEC/FICA 77ONS FOR MA 7FR/AL. 60" MAX. UNLESS FOOT OF S7RAP I DUCT <br /> OVAL 7RANS/770N MA7ER/AL REQU/REMENTS REFER TO AND/NSULAT/ON REQUIREMENTS /5 PLACED UNDER A <br /> PLUMBING ISC PLANS FOR ROUTING, S/ZE, BOTTOM REINFORCEMENT <br /> \ AND DISCHARGE LOCATION. DUCT I <br /> `L/NEAR <br /> GYP.BD. CE7UNG DIFFUSER WIN <br /> CONCEALED Atl7ES <br /> FAST I Q N <br /> FASTENER I. DUCT SMOKE DETECTOR SHALL BE MOIk/TED AID INSTALLED �AIRFLOW I <br /> FER LOCAL CODE REQUIREMENTS. <br /> L 11 <br /> _— CD 00 <br /> 7 LINEAR DIFFUSER DETAIL SCREW KSCREWS MAY B£OMM/IED TYPICAL DX HORIZONTAL UNIT SUSPENSION DETAILImo,• S/ZE BOL7(5) w MIN. _x Q <br /> 4 Q <br /> /F HANGER LOOPS FOR LOAD O <br /> NOT TO SCALE NOT To SCALE STRAP HANGER TRAPEZE HANGER 0 L� <br /> r <br /> RECTANGULAR OR Q o CO W <br /> ROUND OPPOSED Z ¢ Z N <br /> GLADE DAMPER HANGERLOAD RA FU LL <br /> FA TENER D W O�// W 0 W <br /> CINCH BAND O LL O T— > <br /> SECURE WRE HANGER RODS, MN� 0_ 0 <br /> O BAND OF WRES OR STRAPS 0_ co D_ r W <br /> FLEXIBLE CASING SAME SIZE <br /> 7/8"THREADED CAP, AND WRE(50-O" /NSULA 7ED AS HANGER STORE#: 22817 <br /> TAMPER PROOF OPTIONAL STRAP I <br /> MAXIMUM) SHEET <br /> PLAN NSULATED METAL PROJECT#: 60007-039 <br /> FLEXIBLE PLENUM ISSUE DATE: 10.2.2023 <br /> DUCT <br /> DESIGN MANAGER: GRAPHITE <br /> FLEXIBLE CASING AND METAL <br /> PRODUCTION DESIGNER: GRAPHITE <br /> STUD CHECKED BY: <br /> WRE(50=0"MAX/MUM) ROUND TO f <br /> MOUN771VG BRACKET OVAL TRANS/77ON 10"0 MAX. 24"0 MAX. Revision Schedule <br /> ONE <br /> CEILING DIFFUSER LINEAR MAY Bf USED�F BAND Data Description <br /> 3/1BI2024 REV 1:NVAC REDESIGN <br /> CEILING RACK&PIN/ON GYP. BD. CE/UNG DIFFUSER WTH DUCT SHAPE/S <br /> CO WR PLATE OPERATOR CONCEALED 36"0 MAX- MA/VITA/VIED v <br /> cvmvm <br /> MOUNTING BRACKET FASTENER m A o m <br /> <v <br /> ELEVATION CODER PL47F v°npov <br /> SOCKET W7EN014 m z m0 c FSHEETZTIATLE�:NOTE: HANGERS MUST NOT DEFORM DUCT SHAPE 3 NICAL DETAI:m3zm <br /> �mm=yLINEAR SLOT <br /> A ur< :AS SHOWN <br /> 6 REMOTE VOLUME DAMPER CONTROLLER 3 DIFFUSER DETAIL DUCT HANGER DETAIL >m C� <br /> Z <br /> o NOT TO SCALE NOT TO SCALE z m m xl ll SHEET NUMBER: <br /> NOT TO SCALE mom ' M601 1 <br /> z <br />
The URL can be used to link to this page
Your browser does not support the video tag.