Laserfiche WebLink
2 2ND LAYER 5/8"GWB TYPE'X'W.R.GWB LINE THE JOIST BAY WITH 518"TYPE X GYPSUM PENETRATIONS OF VERTICAL ASSEMBLIES PER IBC SECTION 714.3.1 <br /> a WALLBOARD ON FOUR SIDES OF BAY&ENDS. <br /> 5/8"W.R.GWB THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS SHALL COMPLY WITH SECTION <br /> a THE NUMBER OF LAYERS OF GYPSUM BOARD MEMBRANE PENETRATION FIRESTOP- �1, <br /> FASTEN PER MANUF.SPEC 714.3.1.1 OR 714.3.1.2. 'j <br /> y FINISH PER TO MATCH THE NUMBER OF LAYERS REQUIRED SEE"MEMBRANE PENETRATIONS"THIS <br /> OWNER FFOR THE RATED CEILING ASSEMBLY. TYPICAL FRAMING MEMEBERS SHEET EXCEPTION:WHERE THE PENETRATING ITEM ARE STEEL,FERROUS OR COPPER PIPES,TUBES OR <br /> ONE-PIECE `vv 3"SOUND BATT RATED WALL IS PERMITTED TO BE PROTECTED AS FOLLOWCONDUITS,THE ANNULAR SPACE BETWEEN THE TISNG ITEM AND THE FIRE-RESISTANCE- OHNSON BRAUN DING <br /> ACRYLIC TUB i i 1.IN CONCRETE OR MASONRY WALLS WHERE THE PENETRATING ITEM IS A MAXIMUM 6-INCH <br /> ANDSHOWERr 1 I I 152 mm N Suite 52nd Ave.South <br /> 300 <br /> WITH j 11 MEMBRANE PENETRATING ITEM NOT EXCEED 144 SQUARE INCHES T0.929 mA',OCONC CONCRETE,GROUT OR MORTAR IS WALL DOES Suite Seattle, <br /> ( ) Phon WA 98188 <br /> SURROUND 1 - 1-HOUR WALL ASSEMBLY PERMITTED WHERE IT IS INSTALLED THE FULL THICKNESS OF THE WALL OR THE Phone 206.766.8300 <br /> ACOUSTICAL INSULATION @ALL THICKNESS REQUIRED TO MAINTAIN THE FIRE-RESISTANCE RATING;OR <br /> 11 OAIST CAV T ESNG WITHIN STUD 8 O MEMBRANE PENETRATION 2.THE MATERIAL USED TO FILL THE ANNULAR SPACE SHALL PREVENT THE PASSAGE OF ARCHITECTURE <br /> STE 'ionnsonhrauntl.wm <br /> i FLAME AND HOT GASES SUFFICIENT TO IGNITE COTTON WASTE WHEN SUBJECTED TO <br /> ASTM E 119 OR UL 263 TIME-TEMPERATURE FIRE CONDITIONS UNDER A MINIMUM POSITIVE INTERIOR DESIGN <br /> PRESSURE DIFFERENTIAL OF 0.01 INCH(2.49 Pa)OF WATER AT THE LOCATION OF THE Greg L.Allwi <br /> THROUGH-PENETRATION PENETRATION FOR THE TIME PERIOD EQUIVALENT TO THE FIRE-RESISTANCE RATING OF Jeffrey A.Williams, <br /> --- �'- WASTE STACK PER PLUMBING THE CONSTRUCTION PENETRATED. <br /> DESIGN/BUILD FIRESTOP-SEE"THROUGH <br /> PENETRATIONS"THIS SHEET VERTICAL THROUGH-PENETRATION FIRE STOPS PER IBC SECTION 714.3.1.2 <br /> THROUGH PENETRATIONS SHALL BE PROTECTED BY AN APPROVED PENETRATION FIRESTOP <br /> SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479,WTIH A MINIMUM <br /> 5/8"TYPE'X'W.R.GWB,TYPICAL AT BATH ROOM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH(2.49 Pa)OF WATER AND SHALL HAVE AN F RATING <br /> NOTE: OF NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL PENETRATED. <br /> SIDE(OVER SHEATHING WHERE OCCURS PER THIS DETAIL IS FOR VENTING WITHIN A TYPICAL FRAMING MEMBERS THROUGH-PENETRATION ITEM <br /> STRUCTURAL)-VERIFY R.O.FOR TUB& SINGLE DWELLING UNIT IN FIRE-RESISTIVE CAULK <br /> SHOWER- AT PENETRATION 1-HOUR WALL ASSEMBLY WALL MEMBRANE PENETRATIONS PER IBC SECTION 714.3.2 <br /> SPRINKLERED BUILDINGS ONLY. NO FIRE DAMPER IS REQUIRED O THROUGH PENETRATION MEMBRANE PENETRATIONS SHALL COMPLY WITH SECTION 714.3.1 WHERE WALLS OR PARTITIONS <br /> ARE REQUIRED TO HAVE A FIRE-RESISTANCE RATING,RECESSED FIXTURES SHALL BE INSTALLED <br /> 12 TUB OR SHOWER SURROUND AT 1 HR WALL 1s DUCT THROUGH JOIST BAY 2 TYP.PLUMBING INSULATION �'4�PENETRATION PROTECTION SUCH THAT THE REQUIRED FIRE-RESISTANCE WILL NOT BE REDUCED. <br /> 1"=1'-0" 1 1/2"=V-0" 1 1/2"=1'-0" 3"=11-01, EXCEPTION: <br /> /=4" 1.MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR FIRE RESISTANCE-RATED WALLS AND <br /> PARTITIONS BY STEEL ELECTRICAL BOXES THAT DO NOT EXCEED 16 SQUARE INCHES(0.0 103 (�esss <br /> m')IN AREA,PROVIDED THE AGGREGATE AREA OF THE OPENINGS THROUGH THE MEMBRANE 1 \ REGISTERED <br /> DOES NOT EXCEED 100 SQUARE INCHES(0.0645 m')IN ANY 100 SQUARE FEET(9.29 m')OF WALL 1 / . ARCHITECT <br /> AREA.THE ANNULAR SPACE BETWEEN THE WALL MEMBRANE AND THE BOX SHALL NOT - <br /> EXCEED 1/8"(3.1 mm).SUCH BOXES ON OPPOSITE SIDES OF THE WALL OR PARTITION SHALL BE <br /> SEPARATED BY ONE OF THE FOLLOWING: exaev>arxors wnJJnm <br /> 1.1.BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES(610 mm)WHERE THE sTATe av wnswxcTox <br /> (1)LAYER 3/4"APA RATED"EXPOSURE 1" I WALL OR PARTITION IS CONSTRUCTED WITH INDIVIDUAL NON-COMMUNICATING STUD <br /> SHEATHING OVER SUBFLOORING BELOW CAVITIES; -P <br /> TUB IN LIEU OF GYPSUM CONCRETE 1.2.BY A HORIZONTAL DISTANCE OF NOT LESS THAN THE DEPTH OF THE WALL CAVITY <br /> 1 HOUR DEMISING WALL o o WHERE THE WALL CAVITY IS FILLED WITH CELLULOSE LOOSE FILL,ROCKWOOL OR SLAG <br /> PERASSEMBLIES 7p MINERAL WOOL INSULATION; k <br /> TUB AS SCHEDULED 5"AIR GAP v v 1.3.BY SOLID FIREBLOCKING IN ACCORDANCE WITH SECTION 718.2.1; 5 <br /> PLUMBING WALL 1.4.BY PROTECTING BOTH OUTLET BOXES WITH LISTED PUTTY PADS;OR SEE <br /> BY A030 e <br /> w UNIT UNIT 1.5. OTHER LISTED MATERIALS AND METHODS. -t <br /> SANITARY SEALANT - SURFACE MOUNTED - 2.MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL,PROVIDED SUCH <br /> - FIRE EXTINGUISHER - BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE-RATED ASSEMBLIES AND ARE <br /> _ CABINET - INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE LISTING.THE ANNULAR <br /> FLOOR FINISH - - SPACE BETWEEN THE WALL MEMBRANE AND THE BOX SHALL NOT EXCEED 1/8"(3.1 mm)UNLESS R <br /> LISTED OTHERWISE SUCH BOXES ON OPPOSITE SIDES OF THE WALL OR PARTITION SHALL BE R <br /> SEPARATED BY ONE OF THE FOLLOWING: y o <br /> 2.1.BY THE HORIZONTAL DISTANCE SPECIFIED IN THE LISTING OF THE ELECTRICAL BOXES; <br /> GYPSUM CONCRETE 2.2.BY SOLID FIREBLOCKING IN ACCORDANCE WITH SECTION 718.2.1; <br /> FLOOR TOPPING FRONT SIDE 2.3.BY PROTECTING BOTH BOXES WITH LISTED PUTTY PADS;OR <br /> 2.4.BY OTHER LISTED MATERIALS AND METHODS. <br /> AT DUCTWORK PENETRATION OF RATED ELEVATION ELEVATION 3.MEMBRANE PENETRATIONS BY ELECTRICAL BOXES OF ANY SIZE OR TYPE,WHICH HAVE BEEN <br /> FLOOR SHEATHING CEILING ASSEMBLY,AN APPROVED BASIS OF DESIGN:LARSEN'S B2409-SM LISTED AS PART OF A WALL OPENING PROTECTIVE MATERIAL SYSTEM FOR USE IN FIRE- <br /> AUTOMATIC FIRE DAMPER DEVICE RATED qE�� <br /> UNIT OVERALL DIMENSIONS:27.5"H x 13"W x 5.YD RESISTANCE-RATED ASSEMBLIES AND ARE INSTALLED IN ACCORDANCE WITH THE <br /> FOR CEILINGS MUST BE INSTALLED PER ACOUSTICAL SEAL \ INSTRUCTIONS INCLUDED IN THE LISTING. <br /> 1/q" MANUFACTURER'S LISTING. AND TAPE 1/4'GAP1 HOUR FLR/CL'G 8D �3 \SURFACE MOUNTED FIRE EXTINGUISHER CABINET 4.MEMBRANE PENETRATIONS BY BOXES OTHER THAN ELECTRICAL BOXES,PROVIDED SUCH c <br /> (TYP) PER ASSEMBLIES 3/4"=1'0" PENETRATING ITEMS AND THE ANNULAR SPACE BETWEEN THE WALL MEMBRANE AND THE BOX, <br /> FIRE BLOCKING ARE PROTECTED BY AN APPROVED MEMBRANE PENETRATION FIRESTOP SYSTEM INSTALLED AS <br /> TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479,WITH A MINIMUM POSITIVE PRESSURE <br /> 15 FIRE DAMPERS MATERIAL GENERAL FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED IN COMBUSTIBLE DIFFERENTIAL OF 0.01 INCH(2.49Pa)OF WATER,AND SHALL HAVE AN F AND T RATING OF NOT p <br /> 1 1/2"=1'0" CONCEALED LOCATIONS PER IBC SECTION 718. LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL PENETRATED AND BE <br /> FIREBLOCKING(IBC SECTION 718.2):IN COMBUSTIBLE CONSTRUCTION,FIREBLOCKING INSTALLED IN ACCORDANCE WITH THEIR LISTING. <br /> SHALL BE INSTALLED TO CUT OFF CONCEALED DRAFT OPENINGS(BOTH VERTICAL AND 5.THE ANNULAR SPACE CREATED BY THE PENETRATION OF AN AUTOMATIC SPRINKLER, <br /> NOTES: HORIZONTAL)AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS,BETWEEN A PROVIDED IT IS COVERED BY A METAL ESCUTCHEON PLATE. <br /> 1.TUB/SHOWER VALVE AND SPOUT PENETRATIONS SHALL TOP STORY AND A ROOF OR ATTIC SPACE. 6.MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR FIRE RESISTANCE-RATED WALLS AND <br /> 11 SLI6FLOOR(a�BATHTUB BE PROTECTED PER UL FIRESTOP SYSTEM W-L-1049. �7�FLOOR(a�UNIT DEMISING WALL FIREBLOCKING MATERIALS PER IBC SECTION 718.2.1 INSTALLED AT THE FOLLOWING PARTITIONS BY STEEL ELECTRICAL BOXES THAT EXCEED 16 SQUARE INCHES IN AREA,OR <br /> 2.MUD RING SHALL NOT BE INSTALLED.PROVIDE HOLES IN CONCEALED DRAFT LOCATIONS: STEEL ELECTRICAL BOXES OF ANY SIZE HAVING AN AGGREGATE AREA THROUGH THE <br /> 3"=1'-0" GWB FOR PENETRATING ITEMS THAT COMPLY WITH UL 1 1/2"=V-0" MEMBRANE EXCEEDING 100 SQUARE INCHES IN ANY 100 SQUARE FEET OF WALL AREA, 3 <br /> FIRESTOP W-L-1049. A.CONCEALED WALL SPACES(IBC SECTION 718.2.2):FIREBLOCKING SHALL BE PROVIDED PROVIDED SUCH PENETRATING ITEMS ARE PROTECTED BY LISTED PUTTY PADS OR OTHER p <br /> 3.FIRESTOP CAULK SHALL BE SPECIFIED TECHNOLOGIES, IN CONCEALED SPACE OF STUD WALLS AND PARTITIONS,INCLUDING FURRED SPACES, LISTED MATERIALS AND METHODS,AND INSTALLED IN ACCORDANCE WITH THE LISTING. <br /> INC.SPECSEAL SSS OR LCI SEALANT COMPLYING WITH AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS,AS FOLLOWS: m <br /> REQUIREMENTS OF UL FIRESTOP SYSTEM W-L-1049. NOTES: 1.VERTICALLY AT THE CEILING AND FLOOR LEVELS. <br /> ANNULAR SPACE AROUND PIPE TO BE 1/2"MAX. UL LISTED SEMI-RECESSED OR RECESSED FIRE 2.HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET(3048mm) <br /> 4.SUBSTITUTIONS MUST BE APPROVED BY ARCHITECT IN EXTINGUISHER CABINETS FOR USE IN 1-HR HORIZONTAL ASSEMBLIES PER IBC SECTION 714.4 <br /> WRITING PRIOR TO USE. FIRE RESISTIVE CONSTRUCTION.WRAP INSIDE B.CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES(IBC SECTION 718.2.3): <br /> 5.REQUIRED F-RAT ING:1-HOUR MIN. OF STUD SPACE W/5/8"TYPE"X"GWB TO FORM FIREBLOCKING SHALL BE PROVDED AT INTERCONNECTIONS BETWEEN CONCEALED PENETRATIONS OF A FLOOR,FLOOR/CEILING ASSEMBLY OR THE CEILING MEMBRANE OF A `u <br /> 6.REQU RED T-RATING:0 HOUR MIN. FLAT STUD WALL ASSEMBLY PER G.A.FILE VERTICAL STUD WALL OR PARTITION SPACE AND CONCEALED HORIZONTAL SPACES ROOF/CEILING ASSEMBLY NOT REQUIRED TO BE ENCLOSED IN A SHAFT BY SECTION 712.1 SHALL 3 <br /> 1 HR FLR/CLNG 3640. CREATED BY AN ASSEMBLY OF FLOOR JOISTS OR TRUSSES,AND BETWEEN CONCEALED BE PROTECTED IN ACCORDANCE WITH SECTIONS 714.4.1 THROUGH 714.4.4. <br /> 8D SURFACE MOUNTED CABINETS IF THEY VERTICAL AND HORIZONTAL SPACE SUCH AS OCCUR AT SOFFITS,DROP CEILINGS,COVE <br /> ASSEMBLY TYP. PROJECT MORE THAN 4"INTO ACCESSIBLE CEILINGS AND SIMILAR LOCATIONS. PENETRATIONS OF HORIZONTAL ASSEMBLIES PER IBC SECTION 714.4.1 0 <br /> ROUTE OF TRAVEL MUST BE INSTALLED PER THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED HORIZONTAL ASSEMBLIES SHALL COMPLY a <br /> 5/8"TYPE W GWB 0 DETAIL 3/A051 C.STAIRWAYS(IBC SECTION 718.2.4):FIREBLOCKING SHALL BE PROVIDED IN CONCEALED WITH SECTION 714.4.1.1 OR 714.4.1.2 zo <br /> - 5/8"TYPE'X'W.R.GWB w SPACE BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.ENCLOSED EXCEPTION: <br /> SPACES UNDER STAIRS SHALL ALSO COMPLY WITH IBC SECTION 109.9.3. 1.PENETRATIONS BY STEEL,FERROUS OR COPPER CONDUITS,PIPES,TUBES OR VENTS OR <br /> NOTE: _ FIRESTOP CAULK O CONCRETE OR MASONRY ITEMS THROUGH A SINGLE FIRE-RESISTANCE-RATED FLOOR ASSEMBLY <br /> NO PENETRATION 01 PER NOTE#3 a 2 4 4 2 D.CEILING AND FLOOR OPENINGS(IBC SECTION 718.2.5):FIREBLOCKING OF THE ANNULAR WHERE THE ANNULAR SPACE IS PROTECTED WITH MATERIALS THAT PREVENT THE PASSAGE OF <br /> RATED ASSEMBLY SPACE AROUND VENTS,PIPES,DUCTS,CHIMNEYS AND FIREPLACES AT CEILINGS AND FLAME AND HOT GASES SUFFICIENT TO IGNITE COTTON WASTE WHEN SUBJECTED TO ASTM E w <br /> LLOWED FLOOR LEVELS SHALL BE INSTALLED WITH A MATERIAL SPECIFICALLY TESTED IN THE 119 OR UL 263 TIME-TEMPERATURE FIRE CONDITIONS UNDER MINIMUM POSITIVE PRESSURE ' <br /> cl 6 .6 FORM AND MANNER INTENDED FOR USE TO DEMONSTRATE ITS ABILITY TO REMAIN IN DIFFERENTIAL OF 0.01 INCH(2.49 Pa)OF WATER AT THE LOCATION OF THE PENETRATION FOR <br /> DUCT PLACE AND RESIST THE FREE PASSAGE OF FLAME AND THE PRODUCTS OF COMBUSTION. THE TIME PERIOD EQUIVALENT TO THE FIRE-RESISTANCE RATING OF THE CONSTRUCTION <br /> SOFFIT BELOW FIRE RATED SEMI-RECESSED PENETRATED.PENETRATING ITEMS WITH A MAXIMUM 6-INCH(152 mm)NOMINAL DIAMETER SHALL arc <br /> DUCT E.FACTORY-BUILT CHIMNEYS AND FIREPLACES(IBC SECTION 718.2.5.1):FACTORY-BUILT NOT BE LIMITED TO THE PENETRATION OF A SINGLE FIRE-RESISTANCE-RATED FLOOR ASSEMBLY, E< <br /> ASSEMBLY PER PLAN FIRE EXTINGUISHER <br /> FIRE BLOCKING VERIFY CABINET CHIMNEYS AND FIREPLACES SHALL BE FIREBLOCKED IN ACCORDANCE W ITH UL f03 AND PROVIDED THE AGGREGATE AREA OF THE OPENINGS THROUGH THE ASSEMBLY DOES NOT �€ <br /> QUICK 90 METAL ANGLE MATERIAL <br /> SOFFIT FRAMING DUCT FOR CAB.DIM.VERIFY MFR. UL 127 EXCEED 144 SQUARE INCHES(92,900 mm')IN ANY 100 SQUARE FEET(9.3 m')OF FLOOR AREA. go <br /> 2.PENETRATIONS IN A SINGLE CONCRETE FLOOR BY STEEL,FERROUS OR COPPER CONDUITS, o <br /> SEMI RECESSED FIRE 2X WOOD F.EXTERIOR WALL COVERINGS(IBC SECTION 718.2.6):FIREBLOCKING SHALL BE PIPES,TUBES OR VENTS WITH A MAXIMUM 6-INCH(152..)NOMINAL DIAMETER,PROVIDED THE z <br /> EXHAUST DUCTS PER PLAN EXTINGUISHER CABINET STUDS INSTALLED WITHIN CONCEALED SPACES OF EXTERIOR WALL COVERINGS AND OTHER CONCRETE,GROUT OR MORTAR IS INSTALLED THE FULL THICKNESS OF THE FLOOR OR THE 3 c LL I <br /> o: EXTERIOR ARCHITECTURAL ELEMENTS WHERE PERMITTED TO BE OF COMBUSTIBLE THICKNESS REQUIRED TO MAINTAIN THE FIRE-RESISTANCE RATING.THE PENETRATING ITEMS N <br /> ELEVATION CONSTRUCTION AS SPECIFIED IN SECTION 1406 OR WHERE ERECTED WITH COMBUSTIBLE SHALL NOT BE LIMITED TO THE PENETRATION OF A SINGLE CONCRETE FLOOR,PROVIDED THE H ° <br /> z a SHOWER HEAD PLAN FRAMES. AREA OF THE OPENING THROUGH EACH FLOOR DOES NOT EXCEED 144 SQUARE INCHES(92900 La o <br /> 7D e® <br /> �� G.CONCEALED SLEEPER SPACES(IBC SECTION 718.2.7):WHERE WOOD SLEEPERS ARE 3.PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL,PROVIDED SUCH BOXES HAVE w'd <br /> a o. / e RECESSED FIRE EXTINGUISHER CABINET USED FOR LAYING WOOD FLOORING ON MASONRYOR CONCRETE FIRE-RESISTANCE- BEEN TESTED FOR USE IN FIRE-RESISTANCE-RATED ASSEMBLIES AND INSTALLED IN = _o d m p <br /> 4 TUB SURROUND(TILE AT 1 1/2"=1'-01, RATED FLOORS,THE PACE BETWEEN THE FLOOR SLAB AND THE UNDERSIDE OF THE ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE LISTING. L m w z <br /> - WOOD FLOORING SHALL BE FILLED WITH AN APPROVED MATERIAL TO RESIST THE FREE C <br /> ROLL-IN SHOWER) HORIZONTAL THROUGH-PENETRATION FIRESTOP SYSTEM PER IBC SECTION ul U <br /> 1 HR DEMISING WALL PER ASSEMBLIES PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION OR FIREBLOCKED IN SUCH A V y ul w iw <br /> 714.4.1.1.2 <br /> 5"AIR GAP @PLUMBING WALL 5/8"TYPE'X'GWB MANNER THAT THERE WILL BE NO OPEN SPACES UNDER THE FLOORING THAT WILL w a <br /> N 14 DROPPED SOFFIT EXCEED 100 SF(9.3 m')BETWEEN FIREBLOCKING. THROUGH PENETRATIONS SHALL BE PROTECTED BY AN APPROVED THROUGH-PENETRATION L p ¢ <br /> m 5/8"TYPE'X'W.R.GWB FIRESTOP SYSTEM INSTALLED AND TESTED IN ACCORDANCE W ITH ASTM E 814 OR UL 1479,WITH A O w`Z . o ZI 1"=1'-0" MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER(2.49Pa).THE SYSTEM SHALL w Z V o <br /> I FIRES70P CAULK FLOOR/CEILING MEMBRANE PENETRATIONS PER IBC SECTION 714.4.2 HAVE AN F RATING/T RATING OF NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED O r 9 - = w3 <br /> PER NOTE#3 WALL STUD RATING OF THE FLOOR PENETRATED. rn O LL m <br /> ELECTRICAL OUTLET BOX PENETRATIONS OF MEMBRANES THAT ARE PART OF A HORIZONTAL ASSEMBLY SHALL EXCEPTION: <br /> G COMPLY WITH SECTION 714.4.1.1 OR 714.4.1.2.WHERE FLOOR/CEILING ASSEMBLIES ARE 1. FLOOR PENETRATIONS CONTAINED AND LOCATED WITHIN THE CAVITY OF A WALL ABOVE THE <br /> U - - - MEMBRANE PENETRATION- REQUIRED TO HAVE A FIRE RESISTANCE RATING,RECESSED FIXTURES SHALL BE INSTALLED FLOOR OR BELOW THE FLOOR DO NOT REQUIRE A T RATING. <br /> NI SEE"MEMBRANE SUCH THAT THE REQUIRED FIRE RESISTANCE WILL NOT BE REDUCED. 2. FLOOR PENETRATIONS BY FLOOR DRAINS,TUB DRAINS OR SHOWER DRAINS CONTAINED AND <br /> 5/8"TYPE X GYPSUM WALL BOARD FIRE-TAPED PENETRATIONS"NOTES ON EXCEPTION LOCATED WITHIN THE CONCEALED SPACE OF A HORIZONTAL ASSEMBLY DO NOT REQUIRE A T <br /> O PROTECTIVE BOX MUST BE MECHANICALLY THIS SHEET 1.MEMBRANE PENETRATIONS BY STEEL,FERROUS OR COPPER CONDUITS,PIPES,TUBES OR <br /> SECURED WITH STRAPPING AT CORNERS TO RATING. <br /> O CHROME METAL VENTS,OR CONCRETE OR MASONRY ITEMS WHERE THE ANNULAR SPACE IS PROTECTED 3. FLOOR PENETRATIONS OF MAXIMUM 4-INCH NOMINAL DIAMETER PENETRATING DIRECTLY INTO <br /> U STRENGTHEN THE BOX.THE NUMBER OF ESCUTCHEON PLATE ACOUSTICAL BATT INSULATION EITHER IN ACCORDANCE WI TH SECTION 714.4.1 OR TO PREVENT THE FREE PASSAGE OF FLAME METAL-ENCLOSED ELECTRICAL POWER SWITCHGEAR DO NOT REQUIRE A T RATING. <br /> LAYERS OF GYPSUM BOARD TO MATCH THE HOT WATER SUPPLY AND THE PRODUCTS OF COMBUSTION.THE AGGREGATE AREA OF THE OPENINGS THROUGH <br /> 0 NUMBER OF LAYERS REQUIRED FOR THE INLET PER MANUF. THE MEMBRANE SHALL NOT EXCEED 100 SQUARE INCHES(64,500 mm')IN ANY 100 SQUARE <br /> IL RATED CEILING ASSEMBLY. BATTS OR BLANKETS OF MINERAL OR GLASS FIBER FEET(9.3 m')OF CEILING AREA IN ASSEMBLIES TESTED WITHOUT PENETRATIONS. <br /> N z OR OTHER APPROVED NONRIGID MATERIALS SHALL 2 CEILING MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR HORIZONTAL ASSEMBLIES BY STEEL FIRE-RESISTANT JOINT SYSTEMS PER IBC SECTION 715.1 <br /> �2 3"SOUND BATT 1-HOUR THROUGH BE PERMITTED FOR COMPLIANCE WITH THE 10 FOOT ELECTRICAL BOXES THAT DO NOT EXCEED 16 SQUARE INCHES(10,323 mm')IN AREA, <br /> PENETRATION FIRE VALVE HORIZONTAL FIREBLOCKING IBC SECTION 718.2.1.1 PROVIDED THE AGGREGATE AREA OF SUCH PENETRATIONS DOES NOT EXCEED 100 SQUARE JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALLS,FLOOR OR <br /> STOP INSTALLED PER AND ALLOWED AS FIREBLOCKING IN WALLS INCHES(44,500 mm-)IN ANY 100 SQUARE FEET(9.29 m')OF CEILING AREA,AND THE ANNULAR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE <br /> W APPROVED CONSTRUCTED USING PARALLEL ROW OF STUDS OR SPACE BETWEEN THE CEILING MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCH(3.2 mm) PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE <br /> E MANUFACTURER'S STAGGERED STUDS.IBC SECTION 718.2.1.5 3. MEMBRANE PENETRATIONS BY ELECTRICAL BOXES OF ANY SIZE OR TYPE,WHICH HAVE BEEN PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE <br /> 0 REQUIREMENTS. LISTED AS PART OF AN OPENING PROTECTIVE MATERIAL SYSTEM FOR USE IN HORIZONTAL RATING OF THE WALL,FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED.FIRE- <br /> 0 NOTES: <br /> O ASSEMBLIES AND ARE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH SECTION 715.3. PROJECT#: 1827 <br /> 0 1.PLACE 1/16"THICK RESILIENT PADS BETWEEN STUD LISTING. EXCEPTION: <br /> 5/8"TYPE'X'W.R.GWB TO &J-BOXES. 4. DRAWN BY: ST <br /> N FAN WITHIN 1/2"OF TOP OF MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL,PROVIDED SUCH 1. FLOOR WITHIN A SINGLE DWELLING UNIT. <br /> BOX TUB-SEE DET.17 2.ELECT.OUTLET BOX-ALL OUTLET BOXES&SIM. BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE-RATED ASSEMBLIES AND ARE 2. FLOOR WHERE THE JOINT IS PROTECTED BY A SHAFT ENCLOSURE IN ACCORDANCE g BOXES FOR T.V.,PHONE,ETC.IN PARTY WALLS ARE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS INCLUDED IN THE LISTING.THE WITH SECTION 713. CHECKED BY: ST <br /> METAL DUCTWORK. TO BE SEALED W/3M MPP-4S FIRE BARRIER PUTTY ANNULAR SPACE BETWEEN THE CEILING MEMBRANE AND THE BOX SHALL NOT EXCEED 1/8" 3. FLOOR WITHIN ATRIUMS WHERE THE SPACE ADJACENT TO THE ATRIUM IS <br /> N - THREADEDTYPE PAD. 5 FIRE PENETRATIONS <br /> j THE <br /> m N UNLESS LISTED OTHERWISE. INCLUDED IN THE VOLUME OF THE ATRIUM FOR SMOKE CONTROL PURPOSES. <br /> _ BATH TUB 3.ELECT.OUTLET BOXES SHALL BE LOCATED WITHIN THE ANNULAR SPACE CREATED BY THE PENETRATION OF A FIRE SPRINKLER,PROVIDED IT IS 4. FLOORS WITHIN MALLS. <br /> SPOUT 6"OF THE DIMS.SHOWN ON THE ELECT.PLANS. COVERED BY A METAL ESCUTCHEON PLATE. 5. FLOORS AND RAMPS WITHIN OPEN AND ENCLOSED PARKING GARAGES OR NOTES AND DETAILS <br /> U -- 4.IF ELECT.OUTLET BOXES ON OPP.SIDES OF FIRE- 6' NONCOMBUSTIBLE ITEMS THAT ARE CAST INTO CONCRETE BUILDING ELEMENTS AND THAT DO STRUCTURES CONSTRUCTED IN ACCORDANCE WITH SECTIONS 406.5 AND 406.6, <br /> PLASTIC PIPING MATERIAL(MAXIMUM 100 --= FIRESTOP CAULK RESISTIVE WALLS ARE CLOSER THAN 24"THEY SHALL NOT PENETRATE BOTH TOP AND BOTTOM SURFACES OF THE ELEMENT. RESPECTIVELY. <br /> SQ.IN.IN AREA)MAY PENETRATE BOX. - PER NOTE#3 BE STEEL PER PUTTY PAD RQMTS. 7 THE CEILING MEMBRANE OF 1-AND 2-HOUR FIRE RESISTANCE-RATED HORIZONTAL 6. MEZZANINE FLOORS. <br /> EXTEND NO MORE THAN 6"OUTSIDE BOX, 5.ELECTRICAL OUTLET BOXES ON OPP.SIDES OF ALL ASSEMBLIES IS PERMITTED TO BE INTERRUPTED WITH THE DOUBLE WOOD TOP PLATE OF 7. WALLS THAT ARE PERMITTED TO HAVE UNPROTECTED OPENINGS. ///��� <br /> ui AND CONNECT TO THE FIRE STOP. SPOUT WALLS SHALL NOT BE CLOSER THAN 8"O.C.&HAVE AT WALL ASSEMBLY THAT IS SHEATHED WITH TYPE X GYPSUM WALLBOARD,PROVIDED THAT ALL 8. ROOFS WHERE OPENINGS ARE PERMITTED. /\ O <br /> LEAST ONE STUD SEPARATING THEM. PENETRATING ITEMS THROUGH THE DOUBLE TOP PLATES ARE PROTECTED IN ACCORDANCE 9. CONTROL JOINTS NOT EXCEEDING A MAXIMUM WIDTH OF 0.625 INC(15.9mm)AND <br /> 51 <br /> z �\ ����� WITH SECTION 714.4.1.1 OR 714.4.1.2 AND THE CEILING MEMBRANE IS TIGHT TO THE TOP TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263. <br /> wi 13 PROTECTED FAN IN JOIST SPACE / y\_PENETRATION AT TUB 8r SHOWER VALVES �5�ELECT.BOXES ON OPP.SIDES PLATEs. PERMIT SET 10/09/2020 <br /> PENETRATIONS OF HORIZONTAL ASSEMBLIES BY DUCTS OR AIR TRANSFER OPENINGS SHALL <br /> 1 1/2"=V-0" 3"=1'-0" 1 1/2"=V-0" COMPLY WITH SECTION 717. <br />