a UNIT WINDOW SCHEDULE DOOR SCHEDULE
<br /> a SYM. DESCRIPTION I SIZE I U-VALUE SHGC VT CR I NOTES DOOR
<br /> SYM. DESCRIPTION U-VALUE NOTES
<br /> APARTMENTS ELEV SIZE THICK MATERIAL CORE FRAME RATING MAx. OHNSON BRAUNDINC
<br /> APARTMENTS 15200 52nd Ave.South
<br /> A FIXED 5-W 0.W MAX 0.40 MAX 1 UNIT ENTRY A 3070 13/4" METAL Sc HM 20 MIN. 1,2,3,4 Suite 300
<br /> 2 UNITDECK E 3070 13/4" METAL/GLASS Sc WOOD 0.37 1,2,6 Seattle,WA 98188
<br /> B HORIZ.SLIDER Phone 206.766.8300
<br /> 50x56 0.30 MAX 0.40 MAX 1 4 INTERIOR SWING A 3068 13/8" MASONITE HC WOOD
<br /> FIXED 5 INTERIORSWING A 2668 13/8" MASONITE HC WOOD -phnsonhmund.wm
<br /> C FIXED 30x40 0.30 MAX 0.40 MAX 6 INTERIOR SWING A (2)2668 1 3/8" MASONITE HC WOOD _ _ ARCHITECT U RE
<br /> 7 INTERIOR BYPASS C 5068 1 3/8" MASONITE HC WOOD INTERIOR DESIGN
<br /> D HORIZ.SLIDER 50x40 0.30 MAX 0.40 MAX 1 8 INTERIOR BYPASS C 4668 1 318" MASONITE HC WOOD - - Greg L.Allm.,
<br /> FIXED
<br /> COMMON AREAS Jeffrey A.Williams,
<br /> E FIXED 3-56 0.30 MAX 0.40 MAX 1,2 10 ROLL UP GARAGE DOOR D 22'x 8'-2" METAL 13
<br /> VERT.SLIDER 11 STAIR EXTERIOR E 3070 13/4" METAUGLASS Sc METAL 0.37 1561014
<br /> F FIXED 5-0 0,30 MAX 0,40 MAX 1 12 UTILITY EXTERIOR A 3070 13/4" METAL SC METAL ALL:5 6 10 FIRE:7 ELECT:8 16
<br /> 13 MAIN ENTRANCE E 3070 13/4" METAUGLASS SC METAL 0.37 1,5,6,10,14
<br /> G CASEMENT 80x40 0.30 MAX 0.40 MAX 1 13.1 VESTIBULE ENTRANCE E 3070 13/4" METAUGLASS SC METAL 14
<br /> FIXED 14 UTILITY EXTERIOR A 4070 13/4" METAL SC METAL ALL:5,6,10 FIRE:7 ELECT:8,16
<br /> H FIXED 117x40 0.30 MAX 0.40 MAX 15 STAIR INTERIOR @ GARAGE J 3070 13/4" WOOD/GLASS Sc METAL 90 MIN 3,10,12
<br /> 16 ELEVATOR LOBBY @GARAGE E 3070 1314" METAUGLASS SC METAL 0.37 3,10
<br /> 17 UTILITY DOUBLE DOORS A (2)3070 13/4' METAL SC METAL ALL:5,10 FIRE:7
<br /> 18 STAIR INTERIOR @ APARTMENTS J 3070 13/4' WOOD/GLASS SC METAL 90 MIN 310,12
<br /> 19 UTILITY INTERIOR A 3070 13/4" METAL Sc METAL 20 MIN. 10
<br /> 20 UTILITY INTERIOR A 3070 13/4" METAL Sc METAL - 10 asss
<br /> REGISTERED
<br /> 21 TENANT STORAGE A 3070 13/4" METAL SC METAL 20 MIN. 10 ARCHITECT
<br /> 22 TENANT STORAGE A (2)3070 13/4" METAL SC METAL 20 MIN. 10
<br /> 23 ELEVATOR LOBBY @ APARTMENTS A (2)3070 13/4" METAL SC METAL 20 MIN. 3,8,10,17
<br /> 24 ELEVATOR HOISTWAY 3670 STAINLESS SS 90 MIN. BY ELEVATOR MANUFACTURER f F'FRov>aTx[�rs wnJJAM
<br /> 25 BIKE STORAGE A 3670 1 3/a" METAL SC METAL 20 MIN. 10 sTATe av wnswucTON
<br /> 26 POOL NANA WALL K (2)15080 METAUGLASS 20 MIN. 0.37 NANA BI-FOLD DOOR W EXIT MAN DOOR
<br /> 27 FIRE SEPARATION DOOR A 3670 13/4' METAL Sc METAL 90 MIN. 3,8,10,17 STAMP
<br /> 28 REC VESTIBULE EXTERIOR E 3080 13/4" METAUGLASS INSULATED METAL - 0.37 1,5,6,8,10,12
<br /> 28.1 REC VESTIBULE EXTERIOR E 3080 13/4" METAUGLASS INSULATED METAL - 0.37 1,5,6,8,10,12,14 i
<br /> 29 REC VESTIBULE INTERIOR E 3D80 13/4" METAUGLASS HIM METAL - - 1,5,8,10,12
<br /> 30 OFFICES/PUBLIC E 3070 1 3/8" WOOD/GLASS SC WOOD t
<br /> 31 LEASING SLIDING DOOR E 3070 1 3/8" WOOD/GLASS Sc WOOD 15,AS SELECTED BY ID o
<br /> 32 CONFERENCE BARN DOOR F (2)3876 1 3/8" WOOD Sc WOOD 15,AS SELECTED BY ID
<br /> 33 BASKETBALL INTERIOR E 3070 13/4" METAUGLASS HIM METAL 8,10,12 NO WIRE GLASS R
<br /> 34 POOL SHOWER?OILET A 3070 13/4" META(GLASS SC METAL - - 10,12 a
<br /> 35 PUBLIC RESTROOMS A 3070 1 3/8" METAUGLASS SC METAL 11,12 rn o$
<br /> 36 UNISEX RESTROOMS A 3070 1 3/4" WOOD SC WOOD 10,12
<br /> GENERAL UNIT WINDOW NOTES UNIT WINDOW KEYNOTES
<br /> A. WINDOW HEAD HEIGHT AT T-1"ABOVE SUBFLOOR UNO. 1. COORDINATE OPERABLE SIDE OF WINDOW WITH EXTERIOR y
<br /> B. ALL WINDOWS ARE VINYL FRAME,INSULATED DOUBLE ELEVATIONS AND UNIT VENTING OUTLET(3'-0^MIN.
<br /> GLAZED.U-VALUES SHOWN PER ENERGY CALCULATIONS, SEPARATION TO OPERABLE OPENING).
<br /> REFER TO ENERGY CODE REQUIREMENTS ON SHEET CS01. 2. PROVIDE SAFETY GLAZING. GENERAL UNIT DOOR NOTES DOOR SCHEDULE KEYNOTES
<br /> C. MULL OPERABLE UPPER WINDOWS TO LOWERED FIXED
<br /> WINDOWS,TYP.
<br /> D. PROVIDE SAFETY GLAZING(TEMPERED UNLESS NOTED A. ALL DOOR HARDWARE TO SPACES REQUIRED 1. ENTRANCE DOORS SHALL BE CAPABLE OF RESISTING FORCIBLE ENTRY AS A
<br /> OTHERWISE)@ WINDOWS IN HAZARDOUS LOCATIONS PERO TO BE ACCESSIBLE SHALL BE A LEVER OR OTHER SOLID.CORE DOOR 1-3/4"THICK EQUIPPED WITH A DEAD-LOCKING LATCH BOLT.
<br /> IBC SECTION 2406.4 SHAPE WHICH WILL PERMIT OPERATION BY WRIST 2. DEADBOLT WITH 1"MIN.THROW STRIKE PLATE SECURED WITH 2-1/2"MIN.
<br /> E. PROVIDE INDIVIDUAL ROOM OUTDOOR AIR INLET(S)IN OR ARM PRESSURE PINCHING OR TWISTING OF SCREWS.OPENABLE FROM INSIDE WITHOUT KEY OR TOOL.MOUNTING
<br /> WINDOW PER MECHANICAL CODE.GROUP R-2. WRIST TO OPERATE. HEIGHT NOT TO EXCEED 48"AFF.
<br /> F. ALL OPERABLE WINDOWS TO HAVE INSECT SCREENS. 3. SMOKE AND DRAFT CONTROL DOORS COMPLYING WITH UL 1784 SHALL BE
<br /> G. NOT USED B. ALL THRESHOLDS TO SPACES REQUIRED TO BE LABELED IN ACCORDANCE WITH IBC SECTION 716.5.7.1 AND SHALL SHOW THE
<br /> H. INTERIOR WINDOW HEAD&JAMBS TO BE GWB WRAPPED,SILL ACCESSIBLE TO BE MAXIMUM 1/2"HEIGHT-SEE LETTER"S"ON THE FIRE RATING LABEL OF THE DOOR.MINIMUM RATING SHALL
<br /> To HAVE MDF STOOL&APRON PER OWNER FINISH SCHEDULE. A550 BE 20 MINUTES OR HIGHER RATING IF NOTED ON SCHEDULE.DOOR SHALL BE
<br /> J. EXTERIOR WINDOW TRIM AT FIBER CEMENT SIDING=FIBER SELF-CLOSING AND SELF-LATCHING.
<br /> CEMENT TRIM. C. FORCE REQUIRED TO OPERATED DOORS: 4. ALL UNIT ENTRY DOORS TO HAVE DOOR VIEWER AT W-9"AFF.AS AN
<br /> INTERIOR-5.0 POUNDS MAX. ADAPTABLE FEATURE,ENTRY DOORS INTO"TYPE A"ACCESSIBLE UNITS TO 3
<br /> EXTERIOR-8.5 POUNXDS MAX. HAVE AN ADDTIONAL DOOR VIEWER AT 3'-9"AFF.VIEWER HOLE SHALL NOT BE g
<br /> WINDOW ELEVATIONS FIRE DOOR-15.0 POUNDS MAX. LARGER THAN 1"IN DIAMETER THROUGH THE DOOR AND HAVE AT LEAST 1/4"
<br /> THICK GLASS DISC.
<br /> TOP AND BOTTOM WINDOWS MULLED TOGETHER 5'
<br /> D. UNIT INTERIOR DOORS TO BEDROOMS& 5. OUTSWING THRESHOLD&SECURITY HINGES.
<br /> -0" a
<br /> 5'-0" BATHROOMS TO HAVE PRIVACY LOCKS. 6. PROVIDE NAIL FIN FLANGE ON EXTERIOR DOOR FRAME.DO NOT PROVIDE BRICK
<br /> MOULDING.TRIMMED OUT PER EXTERIOR FINISH MATERIAL TRIM.
<br /> EQ EQ EQ EQ E. DOORS TO HAVE 1/2"UNDERCUT @ CARPETED 7. FIRE SPRINKLER&FIRE ALARM PANEL ROOMS SHALL BE MARKED WITH A
<br /> T-0" * EQ EQ AREAS. PLAINLY VISIBLE AND LEGIBLE SIGN STATING SPRINKLER RISER ROOM
<br /> __ __ AND/OR F.A.C.P OR SIMILAR APPROVED WORDING. °
<br /> F. ALL EXTERIOR DOORS&DOORS BETWEEN 8. PANIC HARDWARE PER IBC SECTION 1008.1.10(A OCCUPANCY LOAD y
<br /> CONDITIONED&UNCONDITIONED AREAS SHALL GREATER THAN 50) }t w
<br /> - - BE WEATHER-STRIPPED&INSULATED PER 9. PROVIDE CARD KEY ACCESS ON INTERIOR FOR RESTRICTED ACCESS TO POOL
<br /> ENERGY CODE CALCULATIONS-REFER TO ENERGY DECK. o
<br /> FXD FXD CODE REQUIREMENTS ON SHEET CS01 10. SELF-CLOSING/SELF-LATCHING a rc
<br /> FXD FXD 11. PROVIDE PUSH-PULL HARDWARE,SELF CLOSING/NO LATCH E a
<br /> - - G. DOOR FRAMES&HARDWARE ON RATED DOORS 12. PROVIDE 12"KICKPLATE ON BOTH SIDES OF DOOR BOTTOM. y �€
<br /> FXD FXD FXD _ SHALL BE LISTED FOR THOSE RATING. 13. PROVIDE KNOX BOX IN ACCORDANCE WITH FIRE MARSHAL'S REQUIREMENTS FXD '[
<br /> n r
<br /> FOR4 HOUR ACCESS go
<br /> Io V GYPCRETE - - H. ALL GLAZING IN DOORS SHALL BE LAMINATED 15. DOOR H AR E I CARD READER C SLIDING DOORS.PROVIDE HANDLES AT SLIDING DOORS o
<br /> m M
<br /> OR T.O.CONC. SAFETY GLAZING COMPLYING WITH IBC SECTION 2406.4.1 WITHOUT LATCHES THAT COMPLY WITH ICCA117.1-2009 SECTION 404.2.6& r
<br /> n
<br /> -- ---- -- ---- -- - ------- - NO WIRE GLASS ALLOWED. ( ) STOPS ON SLIDING DOORS SO THAT HARDWARE IS EXPOSED&GRASPABLE 3 c LL
<br /> TOP OF SUBFLOOR WHEN DOORS ARE IN THE FULLY OPEN POSITION.SEE ICC At 17.1-2009. N
<br /> O O O O I. SEE UNIT PLANS FOR DIRECTION HANDING OR DOOR 16. DOOR TO HAVE VISIBLE AND LEGIBLE SIGN STATING"ELECTRICAL ROOM." N c N =
<br /> AT WOOD FRAMING MATCH HEAD TO ¢ o
<br /> ADJACENT DOOR SWING. 17. PROVIDE MAGNETIC HOLDOPENS CONNECTED TO FIRE ALARM. L �'3
<br /> T-0" EQ EQ a'-o^ DOOR ELEVATIONS O J z N8 pj
<br /> mw Z
<br /> as
<br /> V N ��mw 3w
<br /> � EQ EQ
<br /> w a @ ¢ i�
<br /> 3i
<br /> mI oEE LOUVER SAFETY GLASS a z U Z 06
<br /> L o ¢ w
<br /> Z O O 100 S.I.(MAX) O r 3 0 = w 3
<br /> w m O u m
<br /> m FXD FXD FXD �� - i LL
<br /> C
<br /> U TOT N5"
<br /> `I 1"GYP CRETE -
<br /> Ej
<br /> w
<br /> E OR T.O.CONC.i - 5" \ \
<br /> U O O EE
<br /> O \ _
<br /> g w
<br /> 0
<br /> IL
<br /> � EQ EQ EQ EO w O O O O O DOORS PAIR O EXTERIORSLIDING BARN DOOR O LQITE UARTER DOOR
<br /> r6; FLUSH DOOR HALF LITE BYPASS CLOSET DOOR FULL LITE DOOR
<br /> c _______ __ DOOR
<br /> W
<br /> E COIL HOOD PRIMED GALVANIZED STEEL
<br /> o _ BID ALTERNATE-POWDER COATED PER I.D. PROJECT#: 1827
<br /> 0 v
<br /> o i _O- -------- -----_ DRAWN BY: AT
<br /> FXD T. .SUB FLOOR
<br /> g r AT MID LANDING �� CHECKED BY: ST
<br /> T.O.PT SLAB o WINDOW AND DOOR
<br /> SCHEDULE,
<br /> C) ---- - ----------------------------------- ----- " / PANIC HARDWARE ELEVATIONS&DETAILS
<br /> O O / PER MANUFACTURER
<br /> O STAGGERED BRICK GRILL PATTERN O 13I-FOLD GLASS DOOR WITH EXIT MAN DOOR
<br /> < BASIS OF DESIGN Al00
<br /> w GALVANIZED STEEL FINISH AD DOOR MODEL 671 BASIS OF DESIGN
<br /> PERMIT SET 10/09/2020
<br /> GARAGE ROLL-UP DOOR
<br />
|