Laserfiche WebLink
a 26-0" <br /> GENERAL UNIT PLAN NOTES <br /> 0 8'-5" 5'-0- 2'-4" 9'-9" L& <br /> a 7C 1. LEVELS 2.6:TYPE V-A. <br /> 9'-5 1/2" ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDINC <br /> TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> i � Seattle,WA 98188 <br /> REF.`,' S II w `w 11 7C CORRIDOR WALL Phone 206.766.8300 <br /> 0 Y <br /> II �� ^ o- --� 7A EXTERIOR WALL vmvjohnsoabmuad.wm <br /> ------- 1 II I <br /> Ili KITCHEN, li VERIFY, 2 IA110 14 ARCHITECTURE <br /> L - 7D UNIT DEMISING WALLS INTERIOR DESIGN <br /> r <br /> 91 15 y ---13- 1 7g INTERIOR WALL(NON-LOAD BEARING) Greg L.Allwine, <br /> `_____�^ /, I JefFreY A.'Williams, <br /> BATHBATH BOOM I 7g1 INTERIOR WALL(LOAD BEARING) <br /> 1 A110 <br /> I I <br /> < `¢ 12-03/4" 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> KITCHEN WORK z ____i _ <br /> 0 <br /> SURFACE PER ICC zW + -----1--- 1 <br /> -------,At 17.1 AND CITE - II 4. OX DOORTYPE-SEEDOORSCHEDULEONSHEETA100 <br /> I THE CODE - <br /> SECTION 1003.12.3 11 _ ___ <br /> DA 6 D 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> b6 Z 9 1 1 q I <br /> m ,5'- "• s'-s" II I <br /> ¢ VINYL ARPET 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> pW z I (ICC/ANSI 117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> MIRROR ` ALIGN h N I FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> _ 4 i SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS esss <br /> 2" 2" - - SEE UNIT SHEETS FOR"TYPE A. <br /> AND"TYPE B"UNIT PLANS. <br /> 2'"-5" ___5+p_-_ REGISTERED <br /> w -- II SEE ACCESSIBILITY NOTES SHEET A550 <br /> III ARCHITECT <br /> b5 ^ 112" i 112" 4 2�_qy SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> 666\:::JJJ I U I I <br /> 11�5�}����cs1 <br /> bi b2 «1( 1�� i 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS I xxxxv>arxors wn.l.�nm <br /> �1C� (DEFFERED SUBMITTALS) sTATe av wnsxlucTox <br /> KS b7 i 0 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP —P <br /> EXHAUST FAN (2) DRYER VENT <br /> CONTROLS 76 II <br /> LIVING TYP. BEDROOM I I k <br /> ® WHOLE HOUSE FAN PER IMC REQUIREMENTS <br /> s� <br /> POWER VENT WILL BE REQUIRED FOR DRYER e t <br /> 1 II EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> I SPECIFICATIONS.SEE MECHANICAL. o' <br /> a TYPE'A'BATHROOM 13 TYPE'A'BATHROOM 12 TYPE'A'BATHROOM 11 TYPE'A'BATHROOM <br /> 1/4"=V-0" 1/4"=V-0" 1/4"=V-0" 1/4"=T-0" 8. ____ INDICATES LOCATION OF EXHAUST DUCTING 16 Q <br /> 1 1 I K1 SOFFIT FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 <br /> I ru H <br /> FILLER 24" 36' 36" 30" 2T' FILLER FILLER VENT THROUGH ROOF @ 6TH FLOOR 18" 24" 34" FILLER i g INDICATES LOCATION OF DROPPED SOFFIT 2&6 rn <br /> SOFFIT K2 i \\\\\ @ T-0"MIN.SEE DETAIL 2&6 <br /> 10. ALL EXHAUST VENT TERMINATIONS MUST N 3 FEET CLEAR FROM ANY <br /> Ff BLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> 6 Ti:-2 7A ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> `a CL ONE SHROUD,AS POSSIBLE. <br /> K3 K5 K3 y CK 1 0 <br /> M 10'-91/2" <br /> o" 0 11 <br /> I V <br /> d <br /> D K6 Kg RANGE REF -- 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER o <br /> rg — 1ALSO TO ACCESSIBILITY NOTES SHEETS A550. <br /> 24" 36" 36" 30" 15" 13'-5" A 01 P.T. 12'-7" ----- 11 <br /> FILLER 24' 30 X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES <br /> FILLER 26 0 (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> ACCESSIBLE 2 WOOD ---- <br /> CONTROLS A501 f----l l X48' FLOOR SPACE AT ENTRY DOOR PUSH SIDE ALL <br /> I I I UNITS 3 <br /> 1 ' 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE <br /> 10 TYPE'A'KITCHEN �9 TYPE'A'KITCHEN 2 _ I <br /> 1/4"=T-Y' 1/4"=11-0" 1/4^=T-0" L____J J DOORS-TYPE A UNIT ONLY m <br /> 26'-0" i <br /> ' `' 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> 2'-4- 6, I <br /> 14, CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC 14 rc <br /> RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> LL \/O I a <br /> a <br /> J _ REF.`' 15 iiN fn �5 I 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE A051 A051 <br /> ------- I,I o-' ` i I 16. ELECTRICAL PANEL <br /> m <br /> T-5" �, 'A 10 <br /> 81 ' <br /> KRCHENi o- VERIFY I x I 17, S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE w <br /> v ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. �^ <br /> I L O <br /> .- ____ - BATHROOM' I I AV I, IIp <br /> 4 A110 <br /> o � o <br /> ;_ ZW - ----- -- ' UNIT INTERIOR ELEVATION NOTES �€ <br /> L r 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. <br /> 2" c i 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS LL� <br /> " z D D ` AND COUNTERTOPS. 3 N <br /> MIRROR [7 m 9"• 6'-6"4 II i 1d 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR rn <br /> STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 L ¢ <br /> b5 b8 '� DW z ¢ VINYL CARPET o. 0 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 e <br /> ALIGN r+ II w <br /> KITCHEN KEYNOTES BATH KEYNOTES L p <br /> 12'-5" S. <br /> 55 <br /> Iyw aw <br /> �S1S1ZS 1/2", 13 1/2" Q 2'�4" K1 CONCEAL DUCT AT RANGE HOOD bi ACCESSIBLE LAV.SINK AND 1&1 V w a 6'c¢ iw <br /> _ 1 U I EXHAUST,SEE UNIT PLANS FOR COUNTER-TYPE A SINK <br /> g550 a°1 <br /> 0 b I b7 _ III EXTENT OF DROPPED SOFFIT. UNITS-SEE L m E Iu 3z <br /> ml 6 1" p i b2 OPEN KNEE SPACE FOR a Z U o ? o G <br /> Z 24' 12" VERIFY R.O 1 I yw <br /> 18" VERIFY R.O. 7D 1 III O CABINETS W/ADJUSTABLE SHELVES VANITYSINKATALL i6 Q r 3 m m w3 <br /> m I <br /> III PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS N A550 rn O u° m Flf <br /> 1 `------- iI TYPE UNITS.EXTEND <br /> UI 1 LNING BEDROOM i K3 COUNTERTOP FI BACONS. H PER O FLOORING UNDER-SEE A550 <br /> `v I I OWNER SPECIFICATIONS. bg PROVIDE GRAB BARS <br /> rn ADAPTABLE FEATURE FOR <br /> ��TYPE'B'BATHROOM �7 \TYPE'B'BATHROOM 1I ACCESSIBLE WATERCLOSET <br /> �6�TYPE'B'BATHROOM �STYPE'B'BATHROOM 12' 3" @TYPEBUNITS,AND 5 <br /> E 1/4"=V-0" 1/4"=1'-0" <br /> p 1/4"=V-0" 1/4"=T-0" 1 O ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @TYPE A550 <br /> U i 7D K5 HANDLE(ALL UNITS) A UNITS-SEE <br /> 3 SOFFIT 1 I' O PROVIDE GRAB BARS 5 <br /> ti K7 ii K6 REMOVABLE CABINET(ADAPTABLE ADAPTABLE FEATURE FOR A550 <br /> N FILLER 24" 36" 36" 30" 27" FILLER FILLER 18" 24^ 34" FILLER i FEATURE)@OPEN KNEE SPACE FOR SHOWER OR TUB @ TYPE B <br /> m I 34"MAX AFF TO S NKK RIM WORKSPACE2 MIN <br /> IINK AND LOWERED UNITS AND INSTALL GRAB g <br /> SOFFIT K2 BAR @ TYPE A UNITS-SEE <br /> 1 11 KNEESPACE-EXTEND FLOORING A550 <br /> y - O SG O i (TYPE A ACCESSIBLE UNITS ONLY) b5 BOTTOM EDGE OF MAX TO <br /> E - 2 REFLECTING SURFACE. <br /> ��K8 �.� n p I K7 BLIND CORNER CABINET <br /> O _ 5'-11" 5'-0" 2'-6" 6'-0" SURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> 0 N � K3 y 7A MICROWAVE&HOOD PER OWNER O BAR <br /> N K3 0, 05 0 10'-9112" KS SPECIFICATION b7 DRAWN BY: AT <br /> O TUB&SURROUND PER <br /> g u _ OWNER SPECIFICATION. CHECKED BY: ST <br /> RANGE W/FRONT CONTROLS <br /> K6 RANGE )< _ REF DECK K9 (TYPE A ACCESSIBLE UNITS ONLY b8 WIRE SHELVING <br /> D 1 1 BEDROOM PLANS& <br /> RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC <br /> U FILLER 24" 36" 36" 30.' 15' FILLER rr FILLER 24" p T SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> 13'-5" 12'-7" COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> ACCESSIBLE UNITS S ONLY) PECIFICATION. <br /> 26 0" 10 VANITY CABINETS OWNER A 110 <br /> 2 WOOD "ADA COMPLIANT"REFRIGERATOR <br /> ui A501 11 SPECIFICATION. <br /> MAX.54"HT.AFF TO FREEZER <br /> w �a�TYPE'B'KITCHEN rTYPE'B'KITCHENKITCHEN 1 PERMIT SET 10/09/2020 <br /> 1 1/4"=T-0" 1/4"=V-0" 1/4"=V-0" <br />