My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> GENERAL UNIT PLAN NOTES `I�) <br /> v 46_0„ \I <br /> m 1. LEVELS 2.6:TYPE V-A. <br /> 2 /4" 7'-13/4" 2'-8" 7'-10" T-0" 5'-0" 9'-10' 7'-3" 2'-9' 4' - ALL LEVELSFULLY SPRINKLERED PER NFPA 13. <br /> 7C VERIFY - 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDNC <br /> \ TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> 1 LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> O SeatOe,WA 98188 <br /> REF. <br /> 7C CORRIDOR WALL Phone 206.766.8300 <br /> —johnsonbraund- <br /> 7C EXTERIOR WALL ARCHITECTURE <br /> I M.BATH v <br /> - I 411 <br /> _� � 7D UNIT DEMISING WALLS INTERIOR DESIGN <br /> _ Q E� 'L Greg L.Allwine, <br /> 0 <br /> F15 <br /> m <br /> `D > 7g INTERIOR WALL(NON-LOAD BEARING) <br /> o _ I A130- 9--- JeRrey A.W Illlama, <br /> - 1- ❑ I'I 7B1 INTERIOR WALL(LOAD BEARING) <br /> 12 1' IP w II 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> LAUNDRY KITCHEN 1 <br /> BAD I^ 0- II O <br /> - \ ,�.I 1 } 1 rn h U O III 4. X DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> - 1 1 A130 j Z z h KITCHEN WORK j <br /> 7p 1 1 > > P SURFACE PER ICC '-- -- III - <br /> \14 - --i - ' A117.1 AND IT M.CLOSET II 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET A100 <br /> a LL THE CODE <br /> a a CARP VINYL SECTION 1003.12.3 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> '-41/2" 6'-3" ' ----- III (ICC/ANS1117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> IF > .- r, 1-- -- ' >_ pW III FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> bg VERIFY - - 1 <br /> o ,m 1 1 1 1 "v z 2' --J 1 SEE SKEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS <br /> �� ll 2^ S+P I1 1 n1 1 1 S+P 1 SEE UNIT SHEETS FOR"TYPE A"AND"TYPE B UNIT PLANS. s REGISTERED <br /> "_______ __ ______, SEE ACCESSIBILITY NOTES SHEET A550 ARCHITECT <br /> I I - �1 � 1 SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> I - r I I <br /> B+P 0: <br /> - r - ' ¢ 1 41 1 5-8 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS I exaev>arxors wnJJnm <br /> ZS�111� b1 b2 _ O 1 - - - S+p I O •ALIGN 1 (DEFFERED SUBMITTALS) sTATe av wnswxcTox <br /> - 1 I <br /> = KS 1 1 -- -�j 7D Qi HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP <br /> 1 <br /> I w M <br /> r' <br /> ^ <br /> / ILLA 7A �' j 4,_11• 1 8 i LIVING --j-------' O EXHAUST FAN DRYER VENT srunv <br /> 17" 37" Q • I j <br /> 4" 10'-1" 13'-10" 1 11'-10" 1 4„ ® WHOLE HOUSE FAN PER IMC REQUIREMENTS k <br /> I q m <br /> io io <br /> 1 1 1 i m MASTER POWER VENT WILL BE REQUIRED FOR DRYER <br /> 1 EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> SPECIFICATIONS.SEE MECHANICAL. o <br /> 1a TYPE'A'BATHROOM 13 TYPE'A'BATHROOM 12 TYPE'A'BATHROOM BEDRooM2 z'-z" z' a^ <br /> I ( 1 1 8. INDICATES LOCATION OF EXHAUST DUCTING i6 <br /> 1'-0" 1/4"=1'-0" 1/4"=1'-0' BEDROOM 1 I 1 1 ---- R <br /> K1 7A 1 I 1 1 I I FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 R <br /> FILLER-, 36" 30" 36" 36" 24" FILLER 34" 18" 33" 12"LIP FILLER 1 i O 1 1 VENT THROUGH ROOF @ 6TH FLOOR y a <br /> j 2 _ 9. INDICATES LOCATION OF DROPPED SOFFIT 2&6 <br /> SOFFIT K2 SOFFIT O i 4, 5" - O @ T-0"MIN.SEE DETAIL A550 <br /> ' L I 7A` 1 10. ALL EXHAUST VENT TERMINATIONS MUST N 3 FEET CLEAR FROM ANY <br /> I CL I OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> O I DECK ' ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> dilK3 7A I - I 7q 6'-1 1-' ONE SHROUD,AS POSSIBLE. <br /> K3 KS 13 <br /> M T-71/2" <br /> �dw <br /> o <br /> RANG KS K6 REF P.T. 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> W 9'-111/2" 23'-5" A 01 12'-71/z" <br /> ALSO TO ACCESSIBILITY NOTES SHEETS A550. <br /> 18" 33" FILLER 46-0 2 1 1 FILLER 18" 29 3/4" 36 1/4" 36" 24" FILLER A501 WOOD 1 1 30 X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES <br /> ACCESSIB E I I (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> CONTROLS `-----J <br /> E-----1 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> UNITS 3 <br /> 1 ' 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE O <br /> 11 TYPE'A'KITCHEN 10 TYPE'A'KaLjQ LL \3BEDROOM UNIT-TYPEA -- �� DOORS-TYPEA UNIT ONLY , <br /> 1'..=1.4. 1/4"=1'-0" �•, <br /> 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> I � <br /> 46'-0" 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC 14 <br /> 2" —2" 2 /4" T-13/4" 2'-8" T-10" 3'-0' S-0" 9'-10" T-3" 2'-9" 4 = RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> VERIFY a <br /> IRROR 11 12 <br /> 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE <br /> A051 A051 <br /> 16. ELECTRICAL PANEL m <br /> _ b9 '� 1 r' REF. o <br /> 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE w <br /> �S1 �S11< < v ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. 4 <br /> 11U�11�1 3 M.BATH 8 e F <br /> b7 M 7 1 I o-- K i °z <br /> �vl <br /> A130 4 A130 9 FILLER36" 18" O I UNIT INTERIOR ELEVATION NOTES�� �� LAUNDRY 7 III w 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. <br /> / 9 \TYPE'B'BATHROOM / 8 \TYPE'13'BATHROOM I ( Ili it III 2. AFIELD NDC VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS 3o LL� <br /> 1 y 3 KITCHEN 1 7D <br /> -T-F 6 TA130' III ¢ 4O 111 AND COUNTERTOPS. <br /> 1/4"=T-0" 1/4"=T_0" - 76 4 a I U c w o <br /> _ _ _-.. -- - _ 1 z_ +III III 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR m <br /> > w Ih STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 L ¢ o <br /> M.CLOSET IIj 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 p <br /> w CARP VINYL - o d a <br /> bs 6'-3" pN h KITCHEN KEYNOTES BATH KEYNOTES L °w a ?83 <br /> MIRROR > III /O� ul U k VERIFY • z 2'-31/2' - ----JI V N rns 3w <br /> x S+p O > S+P Ki EXOHAUST,SEE UN TNCEAL DUCT AT PLANS FORNGE D bi COUNTEIRL TYPE A&6 E LAV.SINK AND 1&1 a y"¢ zw <br /> ¢ ? <br /> 24" ------ 1 a' EXTENT OF DROPPED SOFFIT. UNITS-SEE A550 L ❑ E w ;z <br /> 16I yb3 l b3 g 7D �I i r ' S'-8" O OPEN KNEE SPACE FOR 3 ¢ w�a ° �G <br /> ZI , �y �I --____= a I O CABINETS W/ADJUSTABLE SHELVES b2 VANITY SINK AT ALL i6 O w z =' <br /> 3' wa <br /> b4 1 S+p I a O PER FINISH SCHEDULE. ACCEPE SSIBLE BATHROOMS IN A550 N O u° m <br /> Ty <br /> �1111� 7 1 O O O ND <br /> S+pl O j •ALIGN K3 COUNTERTOP&BACKSPLASH PER FLOORING IUND UNDER <br /> n <br /> U � �`-- b7--_,1 I 1 ___-_� I I OWNER SPECIFICATIONS. b3 PROVIDE GRAB BARS <br /> `I .__ j i ADAPTABLE FEATURE FOR A550 <br /> I�_'18h LIVING ACCESSIBLE WATERCLOSET <br /> y 24" 12" 1 4'-11" I <br /> E 1 Q • j I @ TYPE B UNITS,AND 5 <br /> O 10,-1" 1 9'-7" I 13,-10" i 11'-10" 4" ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE A550 <br /> U 1 I I K5 HANDLE(ALL UNITS) A UNITS-SEE <br /> 3 7 TYPE'13' OM'BATHRO TYPE'B' BATHROOM MASTER��TYPE BATHR I I MASTER 1 O PROVIDE GRAB BARS 5 <br /> O = I I O REMOVABLE CABINET ADAPTABLE <br /> tl I I 1 K6 ( ADAPTABLE FEATURE FOR A550 <br /> 1/4"=V-0" 1/4"=V-0" 1/4"=V-0" 1 I I FEATURE)@ OPEN KNEE SPACE FOR SHOWER OR TUB @TYPE B <br /> K7 BEDROOM 2 i SINK AND LOWERED WORKSPACE @ UNITS AND INSTALL GRAB g <br /> 1 2' 2" 2' 4" I 1 34"MAX.AFFTO SINK RIM/27"MIN BAR @TYPE A UNITS-SEE <br /> FILLER 36" 30" 36" 36" 24" FILLER 2" 34" 18" 33" 12" FILLER BEDROOM 1 1 I 1 7D KNEESPACE-EXTEND FLOORING A550 <br /> O � UNDER O MIRROR-40"A.F.F.MAX TO <br /> B 1 PE A ACCESSIBLE UNITS ONLV b5 BOTTOM EDGE R 4) SOFFIT K2 SOFFIT 1 i � i � ) <br /> E I 1 I I i REFLECTING SURFACE. <br /> 0 - Op i 4'-5" i O< K7 BLIND CORNER CABINET O SURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> K8 �� '"' 1 - 7A I MICROWAVE&HOOD PER OWNER BAR <br /> JK3 KS DRAWN BY: AT <br /> _ 1 I O SPECIFICATION TUB&SURROUND PER <br /> g K3 KS 7A O DECK W 7A RANGE W/FRONT CONTROLS b7 OWNER SPECIFICATION. <br /> I 6'-71/2" CHECKED BY: ST <br /> (TYPE A ACCESSIBLE UNITS ONLY) b8 WIRE SHELVING <br /> N - T-71/2" 4'-6" 3 BEDROOM PLANS& <br /> RANGE K6 REF 7A RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC <br /> Lj W - CL GL SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> P.T. ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> FILLER 18" 293/4" 36 1/4" 36" 24" FILLER 18 7/166 14 9116" �J-FILLER 9'-111/2" 23'-5" A 01 12-71/2" <br /> 10 VANITY CABINETS OWNER A130 <br /> '� 46'-0" 11 MAX.54'HTLAF TO FREEZ RTOR SPECIFICATION. <br /> ui 2 <br /> A501 WOOD <br /> zwi <br /> �4 TYPE'13-KITCHEN ��TYPE'6'KITCHEN �1 3 BEDROOM UNIT-TYPE B(OPTION B BATHI PERMIT SET 10/09/2020 <br /> 1 114"=V-0" 1/4"=V-0" 1/4"=V-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.