My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL UNIT PLAN NOTES <br /> 13'-9" 6'-9" 7'-0" 3'-0" 5'-0" 2'-6" <br /> < 5'-0 1/2" 1. LEVELS 2.6:TYPE V-A. <br /> 7C VERIFY 7C 7C ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDI <br /> TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> Seam � "° -�- -- LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> i1 88 <br /> REF. 7C CORRIDOR WALL Phonle 206 766.I8300 <br /> r M <br /> _______, , vmvjohnsonbrauntl.wm <br /> v <br /> M. ATH _ _ _ 1 10 7A EXTERIOR WALL ARCHITECT U RE <br /> "• 7D UNIT DEMISING WALLS INTERIOR DUE S I G N <br /> B Simms-C 1531'Ai,01 11tt�_ 4._6.- i ___ O Greg L.Al UES <br /> w O MASTER _ rn VERIFY 1/i BATH 1 ---- - 11---- O 7B INTERIOR WALL(NON-LOAD BEARING) Jeffrey A.Wllllama, <br /> A140 9 KITC�E� 7B1 INTERIOR WALL(LOAD BEARING) <br /> V ' J IJ 4 <br /> _ e <br /> 1> 1 _______ 60 KITCHEN WORK ___ _ _; 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> --CARPE VINYL — m 1> Sip iv SURFACE PER E "_ ___ 7D <br /> i 1 - A1117.1 AND CITE <br /> THE CODE 1 4. 0DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> IN CARPET V L 1 <br /> 10_ SECTION 1003.12.3 1 <br /> i -10 <br /> 1K I ^ _____ 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET Al.. <br /> b6 �4 . 1 � i U 1 ¢ > <br /> o - <br /> W z 1 i 1 z DW 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> all > 1 1 > (ICC/ANSI 117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> vi 1 4 1 I --- FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> b 7A 11 - w ISEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS <br /> 2 to I I M.CL1 a I I 1 =__ 8 "' SEE UNIT SHEETS FOR-YPE A"AND"TYPE B"UNIT PLANS. ^8556 <br /> �L II 1 n Q 1 -4- <br /> S+p - G i SEE ACCESSIBILITY NOTES SHEET A550 1 \/ A CIH TECT <br /> b 1'-6" 6'-0' 16'-1" 5'-8" 1 4'-6 1� 4'-0" U SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> S+p <br /> =______-- j <br /> b4 - - _ - _ 7 I FFRF.Y ARTH[IR riII.I.IAM <br /> 4 _ _ 4 _ __ C 4 _ _ I 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS sTnTe aF wnswucTOH <br /> n < I 1 i (DEFFERED SUBMITTALS) <br /> b7 d77 <br /> KS i i 0 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP sTunv <br /> 17" 37" 1 I EXHAUST FAN DRYER VENT <br /> 1 0 • O I O LIVING i <br /> 1 1 7 I I I I I I WHOLE HOUSE FAN PER IMC REQUIREMENTS k <br /> 1a TVPE'A'BATHROOM 13 TYPE'A'BATHROOM 12 TYPE'A'BATHROOM ________ F_____ __ POWER VENT WILL BE REQUIRED FOR DRYER a t <br /> 1/4"=1'-0" 1/4"=1'-0" al EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S v yE <br /> BEDROOM 1 1 i BEDROOM 2 i BEDROOM 3 i SPECIFICATIONS.SEE MECHANICAL. o <br /> K1 O <br /> 8. ____ INDICATES LOCATION OF EXHAUST DUCTING i6 <br /> FILLER-, 30" 18" 36" 36" 24" FILLER 34" 30" 36" 15" FILLER i i 1 i FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 a <br /> 10'-S" 2'-4"1 9'-10" 10'-8" 14'-8" 4" R <br /> SOFFIT SOFFIT I I VENT THROUGH ROOF @ 6TH FLOOR G7 R� <br /> 9 IND0ICATES LOCATION OF DROPPED SOFFIT <br /> 50 <br /> @ T-"MIN.SEE DETAIL <br /> \ aII i i I I 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> K3 i Ip� OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> 5'-0" 7A II i OF `�' ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> K3 K5 b8 1 5'-2" b'-10" ONE SHROUD,AS POSSIBLE. <br /> _ M W (L o <br /> 11L 5'-11- 5'-3" CL DECK <br /> RANGE _ K6 vo 7A 1 � <br /> W REF KS ao CL CL i 1 <br /> o <br /> 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> FILLER 30"N 24" 36" 24" FILLER 30" 36"NFILLER ALSO To ACCESSIBILITY NOTES SHEETS A550. <br /> ACCES IBLE 13'-10" P.T. 2'-13/4" 1 1 <br /> 30"X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES <br /> 11 TYPE'A'KITCHEN CONTROLS 10 TYPE'A'KITCHEN 1'-6" 10'-6" 12'-6" 25'-6" L - J (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> 1/4"=V-0" 1/4"=1'-0" 50'-0" WOOD T---- 1 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> UNITS 3 <br /> 1 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE <br /> 2 L____U J DOORS-TYPE A UNIT ONLY m <br /> 1/4"=V-0" <br /> i <br /> 50,-V, ; 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> 13'-9" 6'-9" 10'-0" 5'-0" 2'-6" 12' 0" - 3 <br /> 5'-01/2" 7,_0„ <br /> 7C 7C 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC 14 <br /> b6 VERIFY RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> 2^ 2• 1 11 12 <br /> 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE 1 A051 <br /> REF. <br /> A05 <br /> MIRRO = 1 L — —1� I 16. ELECTRICAL PANEL m <br /> G <br /> 7- b5 O 1 s 1 1 I 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE U) o <br /> BATH 1 1 3 <br /> b9 � 6 A140 I 1 1 O I ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. +a <br /> N O MASTER _ VERIFY +- / 1 4'_6" 1 A140 4 O I II 5 <br /> _ b4 <br /> 11 1 M.BATH — O KRCHE 7D E� <br /> b 0 v o <br /> CARPET NYL ® -----� d z �€ <br /> s.P F UNIT INTERIOR ELEVATION NOTES O Co <br /> €o <br /> 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. T z <br /> 7A S+p i w CARPET VINYL 1 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS <br /> �� i o- z AND COUNTERTOPS. <br /> / e \TYPE'B'BATHROOM / 8 \TYPE'B'BATHROOM Q 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR drn 1. <br /> 1/4"=V-0" 1/4"=1'-0" O y i U F STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 L 3 0 <br /> W z i a Z DW 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 p <br /> aII 1 1 > I > ry N <br /> 2" N nO � r ]� O "a KITCHEN KEYNOTES BATH KEYNOTES L w ~ 8 p3 <br /> II M.CLOSET 1 1 6 a I =_______ a 2 5 O <br /> MIRROR _ II U <br /> S i S+p ¢ Ki CONCEAL DUCT AT RANGE HOOD bi ACCESSIBLE LAV.SINK AND rn y Q zrc <br /> x 1 i U 1 EXHAUST,SEE UNIT PLANS FOR O COUNTER-TVPEA&6 1&1 aym <br /> a) 5 1'-6" 6'-0' 6'-1" 5'-8" 4'-6" I 4'-0" A550 L ❑ < <br /> l� N S+P—____= EXTENT OF DROPPED SOFFIT. UNITS-SEE O a E Z Q a <br /> `� 9 b8 - 1 i b2 OPEN KNEE SPACE FOR < Z U o G <br /> ZIb3 b3 q q q 7 O CABINETSW/ADJUSTABLE SHELVES VANITY SINK AT ALL i6 Q r 3 o d w3 <br /> b4 , PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN A550 In O o m <br /> 1111p j l 1 TYPE A UNITS.EXTEND <br /> 1 j K3 COUNTERTOP&BACKSPLASH PER FLOORING UNDER-SEE 9 <br /> ^ 1 n II 1 OWNER SPECIFICATIONS. bg PROVIDE GRAB BARS <br /> N1 b7 1 7 " A o LNING O ADAPTABLE FEATURE FOR A550 <br /> N 17" • 7 1 1 O• -- ''!' O1 ACCESSIBLE WATERCLOSET <br /> 24" 12" - 1 1 @ TYPE B UNITS,AND 5 <br /> O ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE A550 <br /> 0 \ HANDLE(ALL UNITS) A UNITS-SEE <br /> �7 \TYPE'B'BATHROOM 6 TYPE'B'BATHROOM �5 TYPE-a-BATHROOM _ BEDROOM 1 II BEDROOM 2 BEDROOM 3 O PROVIDE GRAB BARS 5 <br /> O 1 REMOVABLE CABINET ADAPTABLE <br /> OC 7D O FEATURE)@ OPEN KNEE SPACE FOR SHOWER OR TUB @ TYPE B A550 <br /> tl 1/4"=V-0" 1/4"=V-0" 1/4"=V-0" tit 1 1 1 K6 <br /> ADAPTABI <br /> N 1 SINK AND LOWERED WORKSPACE @ UNITS AND INSTALL GRAB <br /> m 10'-7" 2'-4"I 34"MAX.AFFTO SINK RIM/27"MIN BAR @TYPE A UNITS-SEE <br /> K1 1 1 1 KNEESPACE-EXTEND FLOORING A550 <br /> a FILLER-, 30" 30" 24" 36" 24" FILLER FILLER 34" 30" 36" 15" FILLER II 1 1'-4" UNDER MIRROR-40"A.F.F.MAX TO <br /> y Aqt 1 1 (TYPE A ACCESSIBLE UNITS ONLY) b5 BOTTOM EDGE OF <br /> SOFFIT JK2 SOFFIT O 1 i O REFLECTING SURFACE. <br /> U aII @BLIND CORNER CABINET <br /> O _ _ _ N \irJ O SURFACE MOUNTED LIGHT <br /> 1 O MICROWAVE&HOOD PER OWNER BAR PROJECT#: 1827 <br /> 5 �o ' S'-2" 1 5'-10" <br /> 7A II 1 1 7A KS O DRAWN BY: AT <br /> N K3 I O SPECIFICATION b7 TUB&SURROUND PER <br /> b8 5'-0" 5'-11" OWNER SPECIFICATION. <br /> g K3 K5 DECK RANGE W/FRONT CONTROLS CHECKED BY: ST <br /> 7A 2'-13/4" K9 (TYPE A ACCESSIBLE UNITS ONLY) b8 WIRE SHELVING <br /> - =o RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC 4 BEDROOM PLANS& <br /> C) RANGE _ K6 W REF I SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> 10'-6" 12'-6" 25'-6" P.T. ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> FILLERS 30" �, 24" �, 36" 24" FILLER 1 1 1 10 VANITY CABINETS OWNER Al 40 <br /> 30" 36" FILLER 50'-0" "ADA COMPLIANT"REFRIGERATOR <br /> w ����� 2 11 MAX.54"HT.AFF TO FREEZER SPECIFICATION. <br /> WOOD <br /> A501 <br /> z �4�TYPE KITCHEN �3�TYPE'B'KITCHEN PERMIT SET 10/09/2020 <br /> wi 1/4"=T-0" 1/4"=V-0" 1 <br /> LL 1/4"=V-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.