8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a FIRE RESISTIVE CONSTRUCTION <br /> a VV <br /> TYPE V-A CONSTRUCTION REQUIRED FIRE RESISTIVE RATINGS IBC 601 <br /> EXTERIOR WALL-BEARING: 1HOUR(INSIDE) TABLE 601,SEC.705.5 OHNSON BRAUNDIxc. <br /> NON-BEARING W/>30'FSD: NO RATING TABLE 602 1. FIRE RESISTIVE ASSEMBLIES ARE TAGGED ON 15200 52nd Ave.South <br /> OPENINGS: UNPROTECTED TABLE 705.8 THE ASSEMBLY PLANS THIS SHEET.SEE SHEET Suite 300 <br /> A040&A0401 SERIES FOR FOR FIRE RESISTIVE Seattle,WA 98188 <br /> 7q INTERIOR WALLS-BEARING: 1 HOUR TABLE 601 ASSEMBLY DETAILS. Phone 206.766.8300 <br /> ❑ ❑ ❑ NON-BEARING: NO RATING TABLE 601 <br /> 2. MARKING AND IDENTIFICATION(IBC 703.7)FIRE ww«.jonnsonbrauntl.wm <br /> �• <br /> 7- Q,f � STRUCTURAL FRAME: 1 HOUR TABLE 601 WALLS,FIRE BARRIERS,FIRE PARTITIONS SMOKE ARCHITECTURE <br /> W BARRIERS,AND SMOKE PARTITIONS OR ANY INTERIOR DESIGN <br /> 7D I 7D 7D 7D I 7 LU STAIRWAY ENCLOSURE(FIRE BARRIER): 2 HOUR SEC.1023.2 OTHER WALL REQUIRED TO HAVE PROTECTED Greg L.Mims, <br /> I I I I } DOORS: 90 MIN. TABLE 716.5 OPENINGS OR PENETRATIONS SHALL BE <br /> I --- I --- I F EFFECTIVELY AND PERMANENTLY IDENTIFIED Jeffrey A.Williams, <br /> r-- I-�--� r-- I --t I I -- .. <br /> O _�lQ __�I LI," <br /> 7J DOORSELEVAT AUTO CLOSING BARRIER): 2HOUR TABLE 3 WITH ENTIFI A ON STENCELING.SUCH <br /> - 7J I ii I � i I I - L_ � I � �I IDOORS(AUTO CL SING PER 71 ) 90 MIN. TABLE 716.5 IDENTIFICATION SHALL <br /> 3.7BID �1 BI OTHER SHAFTS: 2HOUR SEC.713 A.BE LOCATED IN ACCESSIBLE CONCEALED, <br /> $®- �g �g p� OIQ - IiU <01 W FLOOR CEILING,OR ATTIC SPACES. <br /> ---- -- A.3 F FLOOR-CEILING: 1 HOUR TABLE 601,SEC.711 <br /> 7C I r 7C ----t 7C 7A Z ROOF-CEILING: 1 HOUR TABLE 601,SEC.711 B.BE LOCATED WITHIN 15 FEET OR THE END OF <br /> I� I� I� T _ A.4 W ATTIC: UNUSABLE SPACE SEC.711.2.6 EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET <br /> c ® ------� �S LJ "I O�l O I MEASURED HORIZONTALLY ALONG OR PARTITION AND <br /> ®r tY CORRIDOR WALLS(FIRE PARTITION): 1/2 HOUR TABLE 1020.1 <br /> y - I . d DOORS: 1/3 HOUR TABLE 716.5 C.INCLUDE LETTING NOT LESS THAN 3 INCHES IN <br /> -,- - r --J I;�- I, I, n I, I �- ' F_ p`'S Q HEIGHTWITH A MINIMUM 3/8"STROKE IN A CONTRASTING <br /> COLOR INCORPORATING THE SUGGESTED WORDING <br /> MECHANICAL ROOMS: SPRINKLERED TABLE 509 "FIRE AND/OR SMOKE BARRIER-PROTECT ALL (� <br /> � OPENINGS'OR OTHER WORDING. 1 \6 ARCHITECT <br /> 7D 7D 7D 7D 7D 7D 7D 7J CORRIDOR CONTINUITY SEC.708.4 / REGISTERED <br /> DRAFTSTOPPING NOT REQUIRED SEC.718.3.2 EXC.1 EXCEPTION:WALLS IN GROUP R-2 OCCUPANCIES <br /> r - r A•6 SEC.7,8.4.2 EXC.2 THAT DO NOT HAVE A REMOVEABLE DECORATIVE CEILING - <br /> ALLOWING ACCESS TO THE CONCEALED SPACE. <br /> 7q EXTERIOR ARCHITECTURAL ELEMENTS SEC.718.2.E I exaev>arxors wnJJnm <br /> INSTALL FIREBLOCKING @ 20'MAX INTERVALS IN EITHER DIRECTION SO NO sTnTe av wnswxcTox <br /> CONCEALED SPACE GREATER THAN 100 S.F. <br /> A.a A.b A.c A.j AA A.I STAMP <br /> 3-HOUR HORIZONTAL SEPARATION PER 510.2 k <br /> % 1 \ LEVEL 2-6-BLDG A ASSEMBLY KEY PLAN TYPE 1-A CONSTRUCTION <br /> 1"=20'-0" <br /> (V� �V) PRIMARY STRUCTURAL FRAME: 3HOUR TABLE 601 pqtq <br /> W ASSEMBLY PLAN LEGEND o S <br /> NON BEARING NO RATING TABLE 602 -.. <br /> EXTERIOR WALLS(ELECTIRCAL) �� 3-HR FIRE ARRIER <br /> R <br /> INTERIOR WALLS-BEARING: 2 HOUR TABLE 601 -- 2-HR FIRE BARRIER <br /> GARAGE VENTING-CODE GARAGE VENTING-BUILDING INTER OR WALLS-NON-BEARING: NO RATING TABLE 601 y o$ <br /> SEE ENLARGED PLANS FOR DIMENSIONSS OF OPENINGS -------- 1-HR FIRE BARRIER <br /> STAIRWAY ENCLOSURE(FIRE BARRIER): 2 HOUR SEC.1023.2 <br /> GARAGES ARE CLASSIFIED AS PUBLIC PARKING GARAGES WITH AN OCCUPANCY OF S-2 AND TOTAL LENGTH OF EXTERIOR WALLS ON THE GARAGE TIER:661.67' Z DOORS: 2 HOUR TABLE 716.5 <br /> COVERED UNDER IBC SECTION 406.4 40%MINIMUM REQUIRED OPENING LENGTH:264.6T <br /> Y ELEVATOR SHAFT(FIRE BARRIER): 2 HOUR SEC.713 <br /> NATURAL VENTILATION OPENINGS SHALL COMPLY WITH IBC SECTION 406.5.2: HEIGHT OF GARAGE TIER WALLS:9.50' Q DOORS(AUTO CLOSING PER 713.7): 2 HOUR TABLE 716.5 <br /> FOR NATURAL VENTILATION PURPOSES,THE EXTERIOR SIDE OF THE STRUCTURE SHALL HAVE d <br /> UNIFORMLY DISTRIBUTED OPENINGS ON TWO OR MORE SIDES.THE AREA OF SUCH OPENINGS IN TOTAL AREA OF EXTERIOR WALLS ON THE GARAGE TIER:6,285.8 SF N OTHER SHAFTS: 2 HOUR SEC.713 <br /> EXTERIOR WALLS ON A TIER SHALL NOT BE LESS THAN 20%OF THE TOTAL PERIMETER WALL 20%MINIMUM REQUIRED OPEN AREA:1,257.16 SF <br /> AREA OF EACH TIER,THE AGGREGATE LENGTH OF THE OPENINGS CONSIDERED TO BE FLOOR-CEILING: 2 HOUR TABLE 601 <br /> PROVIDING NATURAL VENTILATION SHALL NOT BE LESS THAN 40%OF THE PERIMETER OF THE ALL OPENINGS ARE 5'HIGH WITH A MINIMUM FREE OPEN AREA EQUAL TO 72%OF THE TOTAL. `u <br /> TIER.INTERIOR WALLS SHALL NOT BE LESS THAN 20 PERCENT OPEN WITH UNIFORMLY d <br /> DISTRIBUTED OPENINGS. LENGTH OF PROVIDED OPENINGS:362.17' <br /> PERCENTAGE OF PROVIDED OPENING LENGTH:362.17'/661.67'=54.7%OPENING LENGTH <br /> EXCEPTION:OPENINGS ARE NOT REQUIRED TO BE DISTRIBUTED OVER 40%OF THE FIRE SEPARATION DISTANCE <br /> BUILDING PERIMETER WHERE THE REQUIRED OPENINGS ARE UNIFORMLY DISTRIBUTED OVER AREA OF PROVIDED OPENINGS:1,810.83 SF <br /> TWO OPPOSING SIDES OF THE BUILDING. PERCENTAGE OF PROVIDED OPENING AREA:(1,810.83"72%)/6,285.8=20.74%NET OPENING AREA <br /> 4A <br /> LM <br /> 1B 16 _ L_ ID.6 J` <br /> ------- ____ - _ <br /> 4D 1D IS LINE OF 30'OIIFFSE D'h � I I <br /> I U I / \ <br /> -� f /� ��.� LINE OF 30'-0"OFFSET ---------- o <br /> i <br /> _ <br /> 4D <br /> '- ----- -- --- ------------ - <br /> -- A-- --- _-----_ --- <br /> Al li <br /> s o a li <br /> N <br /> F_G - _r - 1-� - 7 - -0 - �� - �I T = ( A.5 ---- /r AV o UNITS > _ <br /> r �� A_______________-___--___--50 STALLS ____________________ M o <br /> 1B 15 BICYCLES arc <br /> iB / / € <br /> r A.6L.L / <br /> / IC c= <br /> A.6Q <br /> 1B A.a <br /> A.a A.b A.c A.d A.e A.f A.g A.h A.i A.j A.k A.I L o <br /> ®TT L_ 3 <br /> a <br /> Q "w z m 8 ;3 <br /> z \ LEVEL 1-BLDG A ASSEMBLY <br /> \V� vrl U No. <br /> Z ZUo = .13 <br /> QG <br /> ml A.a A.b A.c A.d A.e A.f A.g A.h A.i A.j A.k A.I LL vim- o LL m <br /> U � 9A 9A <br /> I <br /> Q --- _I - __-- --- --- ---- --- ---- ----- --- _-- ___-- _-- ROOF BUILDING PROJECTIONS: <br /> E 7A 56-2 1/8" <br /> O 8D 7J ® 7D ® 7D BD ® 7D ® 7D ® - 7J IBC 705.2 DISTANCE GREATER THAN 3'AND LESS <br /> U _ _LEVEL 6 THAN 30'ALLOWS PROJECTIONS OF 24"PLUS 8" <br /> 7A - ----- ---- -- - ----- - ----- - - -- ------- - 47'-2" FOR EVERY FOOT OF FSD BEYOND TOR <br /> o <br /> BD ® 7J ® 7D ® 7D BD ®- 7D ® 7D ® 7J LEVELS FRACTION THEREOF. <br /> ___ __ ________ ________________----------------------- ---- ____ ---_ _--_---_--__--_ ______ 38'-01/4" <br /> 7A ___ 9D __ ® 7J ®__ 7D ®InI ---7D _ 8D ® 7D ® 7D ® __ 7J <br /> rn - - - -------- - ----- -- - ----- - ---- ---- -- ------- -- -- --- 28'LEOEl2' AREA UNPROTECTED O E 705.8 BUILDING A <br /> 7A 8D -- ® 7J ®01 7D ® 7D BD ® I 7D ® 7D ® 7J LEVEL 3 BLDG.SIDE OF U FSD O WALL AREA PE TABLE AREA OF OPENINGS MAX AREA(NFPA 13 SPRINKLERS) <br /> __ ________ __ ___1--fa <br /> _ _______ _____ _ ______ _ 19'-83/4" LEVEL 2-6 <br /> O 7A 2B _ ® ® ® 2B ® ® ® 7J PROJECT#: 1827 <br /> p 7J 7D 7D 7D 7D WALL >30' 274.10'x9'-23/4"=2,445 SF 6805F/2,445 BE NO LIMIT <br /> LEVEL 2 DRAWN BY: AT,SK,ST <br /> N 1B 10'-6" WALL >30' 81.Vx9'-23/4-514 SF 32 BE 514 SF=6% NO LIMIT <br /> 1 B ,- -'. ,'; I1B, CHECKED BY: ST <br /> LEVEL WALL 3a >30' 63'x 9'-2 3/4"=586 SF 68 SF/586 SF=11% NO LIMIT <br /> y - _ REC LEVEL WALL 3b >15' 200.2'x 9'-2 3/4"=1,862 SF 501 SF/1,862 SF=26% 75% <br /> so _____ =11=11 __=II-11 1-11=__- _=II-11-_ ___=II -___- =II-11 z-s" BLDGA-ASSEMBLY <br /> =11= WALL >30' 79.10'x9'-23/4"=514BE 79BE/514BE=15% NO LIMIT LEVEL PLAN/SECTION <br /> Ci <br /> WALL >30' 274.10'x 10'-6"=2,878 SF 828 SF/2,878 SF=28% NO LIMIT <br /> \ WALL >30' 81.81x 10'-6"=859 SF 120 SF/859 SF=14% NO LIMIT ^S03 <br /> ui �3 \BUILDING A BUILDING ASSEMBLY-SECTION ■V <br /> < 1" 20'-0" WALL 3a >30' 61.5'x 10'-6"= 646 SF 1595F/646 SF=24% NO LIMIT <br /> z WALL3b >15' 200.2'x 10'-6"=2,102 SF 681SF/2,102SF=32% 75% PERMIT SET10/09/2020 <br /> w <br /> LL WALL >39 79.10'x 10'-6"=830 SF 190 BE/830 SF=23% NO LIMIT <br />