My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n 26,-0" <br /> GENERAL UNIT PLAN NOTES <br /> 8'-S, 5'-0" 2'-4" 1.-1. 6' <br /> 60" 1 15 RI 7C 1. LEVELS 2.6:TYPE V-A. <br /> 9'-4 718" ALL LEVELS FULLY SPRINKLERED PER NFPA 13. <br /> 110 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES OHNSON BRAUNDIxc. <br /> N 26" TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> 1 1• !L LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> a II 11 16 -0- <br /> w LL ,� �•� Seattle,WA 98188 <br /> 21" II REF.`,' 5 II�W+I, ` j1 7C CORRIDOR WALL Phone 206.766.8300 <br /> CONTROLS II 17 A110 "-----N-, 1 II ��� 'iI o-1 jo nson rauntl.wm <br /> 7A EXTERIOR WALL w,vv. n b <br /> 10 - ARCHITECTURE <br /> 0 KITCHEN, iv VERIFYI NIT DEMISING WALLS INTERIOR T E N <br /> 2 IA1 <br /> I I 1 7D U RIOR DESIGN <br /> ` - 18 Greg L.A <br /> __ __ \t�J// 7B INTERIOR WALL(NON-LOAD BEARING <br /> GE._ '._____�� _ - ��, I ) Jeffmy A.'Williams,Wllll <br /> 4 - BATHBATH BOOM I 7g1 INTERIOR WALL(LOAD BEARING) <br /> A550 � 1 A110 I 1 <br /> 0 <br /> < `< 12-03/4" 3 REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES <br /> v KITCHEN WORK z - <br /> 18 ' ' -RI$ 17 ' ' -RI$ i6 ' ' -RI$ 15 - PE A RI$ f SURFACE PER ICC �W -- <br /> _ _ _ __ _ o FE <br /> UNIT113 1/"= '-0" UNIT 1.3 -------,At 17.1 AND CITE a, _ I �I 4. OX DOORTYPE-SEEDOORSCHEDULEONSHEETA100 <br /> ,�- -�- 1 THE CODE - <br /> 1 SECTION 1003.12.3 O 1 _ ___ <br /> 1 A 6 D 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET Al.. <br /> b6 CL <br /> Z <br /> I I t 111 <br /> CL m 5'-9"• 1 6'-6" II <br /> ¢ VINYL ARPET 1 0. I v 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> pW z 1 I (ICC/ANSI 117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> MIRROR ` ALIGN 1 ry w I FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> _ --- 4 i SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS esss <br /> 2" 2" -�-J SEE UNIT SHEETS FOR-TYPE A"AND"TYPE B"UNIT PLANS. <br /> 2's-5" S+p REGISTERED <br /> w -------- II SEE ACCESSIBILITY NOTES SHEET A550 <br /> 11I / ARCHITECT <br /> b5 � � ^ 1/2,. i 1/2" 4 SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> 666\:::JJJ I U I I <br /> 11�5�}����cs1 1t0 6'-1,. <br /> bi b2 «1( 1�� Q i 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS f xxxxv>arxors wn.f.fnm <br /> �1C� 1 1� (DEFFERED SUBMITTALS) sTATe av wnsxlucTox <br /> I <br /> KS b7 i 0 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP sTunr+ <br /> 18" 26 3l4" 7D I 7D O EXHAUST FAN (2) DRYER VENT <br /> CONTROLS TP HOLDER 1 76 11 " <br /> MIN. 16 BLOCKING LIVING TYR BEDROOM ® k <br /> WHOLE HOUSE FAN PER IMC REQUIREMENTS <br /> 1� A550 i 'v s <br /> 1 12'-3" 1 I POWER VENT WILL BE REQUIRED FOR DRYER e t <br /> II EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> I SPECIFICATIONS.SEE MECHANICAL. o' <br /> 14 TYPE W BATHROOMTYPE W BATHROOM 12 TYPE W BATHROOMTYPEW BATHROOM <br /> 1/4"=1'-0" UNIT 1.2 1/4"=1'-0" UNIT 1.2 1/4"=1'-0" 1 8. ____ INDICATES LOCATION OF EXHAUST DUCTING <br /> UNIT 1. 1 1/4"=1'-0" UNIT 1.2 i6 <br /> 1 1 1 1 i FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 a <br /> 1 I VENT THROUGH ROOF @ 6TH FLOOR ru H <br /> FILLER 24" 36' 36" 30" 21 FILLER FILLER 18" 24" 34" FILLER 1 I rn o$ <br /> SOFFIT 1 1 9. INDICATES LOCATION OF DROPPED SOFFIT 2&6 <br /> K2 C'I I O i \\\\\ @ T-0"MIN.SEE DETAIL A550 <br /> I` '4'- <br /> - -�V- 10. ALL EXHAUST VENT TERMINATIONS MUST N 3 FEET CLEAR FROM ANV <br /> 6'-2" 4'-9" 2'-4" W-4" , OPERABHANICALE AIR INTAG INTO KE. <br /> INATI FEET CLEAR FROM <br /> ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> 1 7A CL ONE SHROUD,AS POSSIBLE. <br /> K3 K5 K3 v DECK o_ <br /> MW 11 ia,-0, - <br /> o= <br /> K6 �I` KS RANGE rj <br /> L REF o <br /> p AREA --- ---- 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER = <br /> ALSO TO ACCESSIBILITY NOTES SHEETS A550. <br /> 1T-5" A 01 P.T. L 12'-7" x <br /> 24" 36" 36" 30" 15" 1 8 FILLER 24" 30 X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES <br /> FILLER 26 0 (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> 2 ACCESSIBLE qWOOD <br /> 1E 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> A550 ONTROLS <br /> I I 1 UNITS m <br /> ' 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE $10 �s�TYPE-0" KITCHEN 2 ROOM UNIT-TYPE A <br /> 1/4"=1'-0" 1/4"=1'-0" 1/4"=1'-0" L____J J DOORS-TYPE A UNIT ONLY o <br /> UNIT 1.2 1 <br /> 26-0" i <br /> ' `' 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> 2,-q" <br /> G <br /> 14, CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REACH(14 rc <br /> Q RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 <br /> LL I I <br /> F <br /> , Ia 1 (� I 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE 11 12 <br /> 15" IIw w _- I A051 A051 <br /> -, '' 16. ELECTRICAL PANELT-5- 'a VERIFY I I 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE <br /> 11 rnJ ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF.//�6' 1 BAT OP< < 2'-03/4" <zWt ______ UNIT INTERIOR ELEVATION NOTES ;d <br /> 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE.2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETSDAND COUNTERTOPS.MIRROR "• &-6"4 II i 1d 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOORSTRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9I DW _ ¢ VINYL CARPET a 0 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 3 p <br /> ALIGN y 11 <br /> KITCHEN KEYNOTES BATH KEYNOTES L p <br /> S+p C m w Q U r%1 03 <br /> =____ li i w Zi aw <br /> _ �S1S1ZS 1/2" 131/2" Q 2'�4" K7 CONCEAL DUCT AT RANGE HOOD bi ACCESSIBLE LAV.SINK AND 1&1 y w a t< zw <br /> N _ 0 Q U I EXHAUST,SEE UNIT PLANS FOR COUNTER-TYPE A&6 g550 L p <br /> 1 b I b7 6'-1" EXTENT OF DROPPED SOFFIT. UNITS-SEE p a EZ Qa <br /> I j it I O OPEN KNEE SPACE FOR ¢ w U o G <br /> ZI 18" 24" 12" HOLDER 7D II K2m <br /> VERIFY R.O. VERIFY R.O. TP I 1 III CABINETS WI ADJUSTABLE SHELVES b2 VANITY SINK AT ALL i6 1Q, Z _ <br /> 443/8" rt BLOCKING 1 1 III PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN A550 LL rn O u- m �� <br /> 33"MIN. TYPE A UNITS.EXTEND <br /> U . i K3 COUNTERTOP&BACKSPLASH PER FLOORING UNDER-SEE <br /> 1 I OWNER SPECIFICATIONS. b3 PROVIDADAPTA GRABLE BARE FOR A550 <br /> �� LIVING BEDROOM I <br /> y 8 7 'B'BAT / 6 \TYPE'B'BATHROOM, 5 I ACCESSIBLE WATERCLOSET <br /> U 1/4"=1'-01, OP 10 B� 1/4"=1'-01, ',.OPTION B� 1/4"=V-0" PTIO B 1/4"=1'-0"' OPTIO B� 12-3 I' ADA COMPLIANT FAUCET W/LEVER W TYPE B UNITS,AND <br /> ALL GRAB BAR @ TYPE A550 <br /> 3 SOFFIT i 7D K5 HANDLE(ALL UNITS) A UNITSO PROVIDE GRAB BARS 5 <br /> ti K7 I� K6 REMOVABLE CABINET(ADAPTABLE ADAPTABLE FEATURE FOR A550 <br /> FILLER 24" 36" 36" 30" 27" FILLER FILLER 18" 24" 34" FILLER i FEATURE)@OPEN KNEE SPACE FOR SHOWER OR TUB @ TYPE B <br /> N I @ UNITS AND INSTALL GRAB g <br /> SINK AND LOWERED WORKSPACE <br /> SOFFIT K2 Q II 34"MAX.AFF TO SINK RIM/27"MIN BAR @TYPE A UNITS-SEE <br /> I' KNEESPACE-EXTEND FLOORING A550 <br /> N B G 1' (TYPE A ACCESSIBLE UNITS ONLY) BOTTOM EDGE OFMAX TO <br /> E REFLECTING SURFACE. <br /> , LLI n p I K7 BLIND CORNER CABINET <br /> OJJ _ 5'-11" 5'-0" 2'-6" 6'-0" b0 SURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> 0 I K3 y 7A MICROWAVE&HOOD PER OWNER O BAR <br /> K3 0, 05 0 - _ F. <br /> GL 10'-91/2" (L KS SPECIFICATION b7 DRAWN BY: AT <br /> O TUB&SURROUND PER <br /> OWNER SPECIFICATION. CHECKED BY: ST <br /> K6 RANGE ll _ REF DECK K9 (TYPE A ACCESS BLE UNT SLONLY) b8 WIRE SHELVING <br /> D 1 RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC <br /> 1 BEDROOM PLANS& <br /> U FILLER 24" 36" 36" 30" 15' FILLER M FILLER 24" p T SWITCH AT46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> 13'-5" 12'-7" COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> 7 26' 0" ACCESSIBLE UNITS ONLY) SPECIFICATION. 0 <br /> A550 10 VANITY CABINETS OWNER <br /> ui 1 A501 WOOD "ADA COMPLIANT"REFRIGERATOR <br /> 11 MAX.54"HT.AFF TO FREEZERA11 SPECIFICATION. <br /> w TYPE'B'KITCHENKITCHEN rTYPE'B'KITCHENKITCHEN �1 BEDROOM UNIT-TYPE B(OPTION B BATHIBEDROOM UNIT-TYPE B(OPTION B BATH1 PERMIT SET 10/09/2020 <br /> Ii 1/4"=T-0" 1/4"=V-0" 1/4"=T-0" UNIT 1.1 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.