Laserfiche WebLink
o. GENERAL UNIT PLAN NOTES <br /> 38'-0" 1. LEVELS 2.6:TYPE V-A. <br /> 10'- 5'-0" ll'-6" 2'-10" 8'-4" 4 ALLLEVELS FULLYSPRINKLEREDPERNFPAI3. <br /> 60" 2. SEE SHEETS A040-A041 FOR FIRE-RESISTIVE ASSEMBLY TYPES JOHNSON BRAUNDIxc <br /> 17 UNIT 2.3 1'-8" 1 7C TYPICAL WALL TYPES: 15200 52nd Ave.South <br /> y 1 A720 LEVELS 2 TO 6-TYPE V-A CONSTRUCTION Suite 300 <br /> 26 Sealtle,WA 98188 <br /> WALL MOUNTED, I - --- -- l _�_ _ 7C CORRIDOR WALL Phone 206.766.8300 <br /> FOLDING ROLL-IN 20 131 -phnsonbmund.wm <br /> SHOWER SEAT. 21" O/' �� `' REF. rR <br /> 7A EXTERIOR WALL <br /> CONTROLS 1 Al2 16I "'> _� VIER ARCHITECTURE <br /> A120 19 Q r 7D UNIT DEMISING WALLS INTERIOR DESIGN <br /> 36" 6" 3" 24" '° 2'-10 g Greg L.Al I.. <br /> _ 15 VE IFY II 7B INTERIOR WALL(NON-LOAD BEARING) Jeffrey A.Wllllama, <br /> 18-2 O\I --L _ - 11.,KITCHEN INTERIOR WALL(LOAD BEARING) <br /> 4 BATH 1� --- > M. Y <br /> A550 O O 3. REFER TO OWNER PROVIDED FINISH&FIXTURE SCHEDULES. <br /> > S+p im <br /> A720 12 I <br /> I I . I 4. X DOOR TYPE-SEE DOOR SCHEDULE ON SHEET A100 <br /> A PET VINY iv ` <br /> 20 -RIS 19 -RIS 18 -RIS 17 - PE A RIS �,T�- <br /> ,n KITCHEN WORK II i� r <br /> il4"=1'-0"• UNIT 2.3 ' UNIT 2.3 ' UNIT 2.3 1/4"=1'-0" UNIT 2.3 Q 1 2" r 12'-10" 3'-10" SURFACE PER ICC III I a 5. O WINDOW TYPE--SEE UNIT WINDOW SCHEDULE ON SHEET Al.. <br /> 1 a A717.1 AND CITE THE III ICLOSET aCODE SECTION 1003.12.3 ---_ III I O I O I w � II � I 6. ALL UNITS ON AN ACCESSIBLE STORY SHALL COMPLY WITH WASHINGTON STATE <br /> b6 � (ICC/ANSI117.1)"TYPE B".SEE FLOOR PLANS FOR LOCATIONS. <br /> n °___7_ < 1 z DW rn __ FIVE PERCENT OF TOTAL NUMBER OF UNITS ARE DESIGNATED AS"TYPE A"UNITS <br /> II .-U--- U > I, SEE SHEET A020 FOR TYPE A CALCULATION.SEE FLOOR PLANS FOR LOCATIONS <br /> SEE UNIT SHEETS FOR"TYPE A'AND"TYPE B"UNIT PLANS. <br /> REGISTERED <br /> MIRROR r, II ___ __I _ _ _ __ W "------- ----- SEE ACCESSIBILITY NOTES SHEET A550 <br /> ARCHITECT <br /> I SEE SHEET A550 FOR ACCESSIBLE DETAILS <br /> � <br /> II > IY III <br /> Q I II • I I' b8 7. REFER TO SEPARATE ELECTRICAL&MECHANICAL DRAWINGS I <br /> S+ M <br /> esxTanTe <br /> P (DEFFERED SUBMITTALS) <br /> ^ T <br /> S1ZpOZS1 b iv qj 1-7I =_______ ? ; 0 HARDWIRED SMOKE/CO DETECTOR W/BATTERY BACK-UP -P <br /> 1 j 1 <br /> I � � O EXHAUST FAN (2) DRYER VENT <br /> III 4'-11' 6'-6" ® WHOLE HOUSE FAN PER IMC REQUIREMENTS k <br /> CONTROLS 253/4" 18" TP HOLDER II i MASTER <br /> MIN. BLOCKING II j POWER VENT WILL BE REQUIRED FOR DRYER _t <br /> -5" 14'-9" I 1V-2" 4" - EXHAUST LENGTHS THAT EXCEED MANUFACTURER'S <br /> SPECIFICATIONS.SEE MECHANICAL. o' <br /> 18 TYPE' 'BATHROOM15 14 13 w <br /> 1/4"=V-0" U IT .2 1/4"=V-0" U IT .2 1/4"=1'-0" U IT .2� 1/4"=V-0" U IT .� i LIVING INDICATES LOCATION OF EXHAUST DUCTING i6 <br /> 1 1 1 rn 2 8' R <br /> BEDROOM 1 WOOD 7D FOR DUCTS WITHIN JOIST SPACE-SEE DETAIL A051 R <br /> K1 A501 VENT THROUGH ROOF @ 6TH FLOOR y o$ <br /> FILLER-, 45" 36" 36" 24" FILLER FILLER 34" 18" 36" 30" FILLER 7D j j 9. INDICATES LOCATION OF DROPPED SOFFIT 2&6 <br /> I P.T. ����� @ 7'-0"MIN.SEE DETAIL A550 <br /> SOFFIT K2 SOFFIT 1 V-4 A901 1 <br /> LPL 10. ALL EXHAUST VENT TERMINATIONS MUST BE 3 FEET CLEAR FROM ANY <br /> �' i j B F I I i � O i OPERABLE OPENING INTO THE BUILDING,AND 10 FEET CLEAR FROM <br /> ANY MECHANICAL AIR INTAKE.GANG TERMINATIONS TOGETHER UNDER <br /> ONE SHROUD,AS POSSIBLE. <br /> K3 c <br /> K3 KS 7A o <br /> M I r <br /> 11 5'-11 1/2" DECK <br /> 7A y <br /> RANGE K6 - KS 13. REQUIRED CLEAR FLOOR SPACES AS SHOWN ON PLANS:REFER <br /> Sro REF WORK 11'-11" 5'-2" 10'-101/2" 5'-61/2" <br /> x w - AREA ✓ ALSO TO ACCESSIBILITY NOTES SHEETS A550. <br /> M I I 30"X48"CLR.FLOOR SPACE AT FIXTURES&APPLIANCES 8 <br /> FILLER 30' 18" 36" 24" FILLER 18" 36" 18" FILLER 14'-0" (CENTERED)&ONE AREA FREE OF DOOR SWING IN BATH <br /> ACCESSIBLE 2 38' 0" `----- <br /> CONTROLS L f----l l 48"X48"CLR.FLOOR SPACE AT ENTRY DOOR PUSH SIDE-ALL <br /> A550 I 1 I UNITS m <br /> \ :I 54"X60"CLR.FLOOR SPACE AT PULL SIDE OF ALL PASSAGE $12 TYPE'A'KITCHEN 11 �2 \2 BEDROOM UNIT-TYPE A <br /> 1/4"=V-0" 1/4"='RO° 1/4"=1'-0" U IT .2 L----JJ DOORS-TYPEA UNIT ONLY o <br /> CL 38.-0.. 1 `I 60"MANEUVERING CIRCLE-TYPE A UNITS ONLY <br /> b6 10'-0" 5'-0" 11'-6" 2'-10" 8'-4" 4' <br /> 7C p <br /> 14. CONTROLS,FAN WALL SWITCH&OUTLETS TO BE WITHIN REAC 14 <br /> e b9 <br /> RANGES-SEE ACCESSIBILITY NOTES SHEET A550&DETAIL A550 0 b5 °° M" 'a <br /> 5 <br /> ZO <br /> REF. g 15. FOR TUBS AT FIRE-RATED WALL AND FLOOR ASSEMBLIES-SEE 11 12 <br /> b3 - 00' f`1 A051 A051 <br /> �S1 �S1ZS i 6r A120 8 "',> - 2'-10" (�/J m <br /> - i6. ELECTRICAL PANEL <br /> �n I ° II - m <br /> 1ti�01t1 F_ I I T VE IFY VERIFY o-- A720 o <br /> b1t <br /> _ _� .J I I 17. S+P=SHELF&POLE.CLOSET SHELF&POLE IN TYPE A UNITS TO BE (n o <br /> u' I 7 "' ADJUSTABLE TO BE WITHIN REACH RANGE 48"MAX.AFF. 4 <br /> L -----------J <br /> 1T 30' 15" FILLER _` OPTION ;`-------'KITCHEN to <br /> I V O_Vp m <br /> 4 3 � } E e� <br /> ° > S+P Al2o a =- r, UNIT INTERIOR ELEVATION NOTES <br /> ---- <br /> 10 TYPE'B'BATHROOM �9�TYPE'B'BATHROOM 1 1 5 J <br /> 7'-2" r 2'-10" T-10" a 1 <br /> 1/4"=V-0" 1/4"=V-0" M.CLOSET a a 1 1. DIMENSIONS ARE TO FACE OF G.W.B(NET),UNLESS NOTED OTHERWISE. <br /> VINY _ <br /> q PET % NII U I 2. FIELD VERIFY ALL FINISHED DIMENSION PRIOR TO ORDERING CABINETS r LL <br /> - II AND COUNTERTOPS. 3 N <br /> I>6 U Lu w II 4O 1 3. PROVIDE BLOCKING AT TOILET PAPER HOLDERS,TOWEL BARS,DOOR rn <br /> to -v > II I STRIKES,DRAPERIES,REMOVABLE CABINET SUPPORTS&GRAB BARS. 5&9 N <br /> MIRROR _ 6 U j DW II i 4. TYPICAL CABINET SYSTEM PROFILE,SEE DETAIL A550 L �3 e® <br /> I I 1 = N Q <br /> o d m w <br /> w z a i 4'-4" i KITCHEN KEYNOTES BATH KEYNOTES O <br /> O > < 4 V u ik <br /> o <br /> l\l �� n' --------- ----- - �o c¢i I K1 CONCEAL DUCT AT RANGE HOOD b1 ACCESSIBLE LAV.SINK AND 1&1 w a NQ zw <br /> cSL�seticS�tS b3 b3V Y\ j qO j OEXHAUST,SEEUNITPLANSFOR O COUNTER-7VPEA&6 g550 L p ¢m <br /> �O9OJ 1 1 EXTENT OF DROPPED SOFFIT. UNITS-SEE E W - �Y <br /> ZI S1�S1ZS1 ` N ===S+P=== > i b2 OPEN KNEE SPACE FOR a ZUo m oG <br /> - 1 O CABINETS W/ADJUSTABLE SHELVES VANITYSINKATALL i6 G r 3 -a <br /> w3 <br /> M <br /> PER FINISH SCHEDULE. ACCESSIBLE BATHROOMS IN A550 O Iu <br /> TYPE A UNITS.EXTEND <br /> I I 4'-11" 6'-6" i K3 COUNTERTOP&BACKSPLASH PER FLOORING UNDER-SEE g <br /> U 12" 24" 18" 1 MASTER 1 OWNER SPECIFICATIONS. bg PROVIDE GRAB BARS <br /> TP HOLDER II I O ADAPTABLE FEATURE FOR A550 <br /> MIN. BLOCKING 4"Ii 11'-5" 14'-9" 11'-2" i4^ ACCESSIBLE WATERCLOSET <br /> ON 43 3/4"(33"MIN.) 1 @ TYPE B UNITS,AND 5 <br /> '� y I ADA COMPLIANT FAUCET W/LEVER INSTALL GRAB BAR @ TYPE A550 <br /> U g " 7 ' 6 " 6 " 7D i y LIVING 2 K5 HANDLE(ALL UNITS) A UNITS-SEE <br /> 1/4"=1'-0", OPTION B 1/4"=1'-0"' OPTIO B 1 11.1=1'-0", OPTION B� 1/4"=1'-0", OPTION B i BEDROOM 1 WOOD O PROVIDE GRAB BARS 5 <br /> ( ADAPTABLE FEATURE FOR A550 <br /> Ii A501 7D K6 REMOVABLE CABINET ADAPTABLE <br /> K1 I 1 FEATURE)@ OPEN KNEE SPACE FOR SHOWER OR TUB @ TYPE B <br /> FILLER 15" 18' 30" 18" 36" 24' FILLER FILLER M" 18"6 36" 30" FILLER i SINK AND LOWERED WORKSPACE @ UNITS AND INSTALL GRAB g <br /> P.T. 1 34"MAX.AFF TO SINK RIM/27"MIN BAR@TYPEAUNITS-SEE <br /> SOFFIT K2 SOFFIT Q A901 UNDER ESPACE-EXTEND FLOORING A550 <br /> y > B <_ OD I (TYPE A ACCESSIBLE UNITS ONLY) O BOTTOM EDGE OF MAX TO <br /> E j 1 REFLECTING SURFACE. <br /> c <br /> O O KS 00 O K3 K7 BLIND CORNER CABINET SURFACE MOUNTED LIGHT PROJECT#: 1827 <br /> 7A MICROWAVE&HOOD PER OWNER BAR <br /> N K3 KS MW DECK I KS SPECIFICATION b7 DRAWN BY: AT <br /> g 0 7A 5 11 1/2 I RANGE W/FRONT CONTROLS TUB&SURROUND PER <br /> ,0 11 OWNER SPECIFICATION. CHECKED BY: ST <br /> K9 b8 WIRE SHELVING <br /> y RANG K6W REF _ 11'-11" v 5'-2" 16'-01/2'10'-101/2" 5'-6112" I O (TYPE O 2 BEDROOM PLANS& <br /> 1 RANGE HOOD ONLY.PROVIDE WALL b9 PLASTIC <br /> SWITCH AT 46"MAX.AFF.PROVIDE LAMINATECOUNTERTOP& ELEVATIONS <br /> FILLER 18" 30" 18" 36" 24" FILLER 18" 36" 18" FILLER COUNTERTOP MICROWAVE(TYPE A BACKSPLASH PER OWNER <br /> U0�00 14-0" <br /> ACCESSIBLE UNITS ONLY) SPECIFICATION. <br /> 7 38'-0" 10 VANITY CA OWNER <br /> A550 11 "ADA COMPLIANT"REFRIGERATOR SPECIFICATION.CABINETS Al 2 0 <br /> ui MAX.54"HT.AFF TO FREEZER SPECIFICATTION. <br /> w r4�TYPE'B'KITCHEN 3�TYPE'B'KITCHEN �l�2 BEDROOM UNIT-TYPE B IOPTION B BATHI PERMIT SET 10/09/2020 <br /> 1 1/4"=1'-0' 1/4"=1'-0.1 UNIT 2.1 1 <br />