Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES <br /> 1. LEVELS 2-6 TYPE VA CONSTRUCTION <br /> R2 OCCUPANCIES <br /> OHNSON BRAUNDl- <br /> a <br /> 2, ALL LEVELS FULLY SPRINKLERED PER 15200 52nd Ave.South <br /> IBC SECTION 903.3.1.1(NFPA 13). Suite 300 <br /> 3 REFER TO SHEETS CS03 FOR FIRE Seatt ,WA 98188 <br /> ASSEMBLY KEY PLAN W/WALL TYPE Phonele 206.766.8300 <br /> TAGS&LOCATIONS.REFER TO vmvjohnsonhmund— <br /> SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> DETAILS. INTERIOR DESIGN <br /> 4. SEE ENLARGED UNIT PLANS FOR ALL Greg L.Allme, <br /> INTERIOR DIMENSIONS,WINDOW AND Jeffrey A.Williams, <br /> DOOR CALL-OUTS,AND RATED WALL <br /> TAGS <br /> 5 EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> ALL VERTICAL SHAFTS SHALL BE 2- <br /> 6' HOUR RATED PER IBC SECTION 713.4. <br /> 7. ODOOR TYPE-SEE SCHEDULE <br /> SHEET A100 <br /> 8. REFER TO SHEET SERIES A100 FOR asss <br /> UNIT PLAN DOOR&WINDOW REGISTERED <br /> SCHEDULE. ARCHITECT <br /> 9. REFER TO SHEETS At 10,At 20, <br /> A130,A140,A150&A151 FOR e"T-AT7 <br /> ENLARGED UNIT PLANS. wnsxlxcTox <br /> 10. REFER TO ACCESSIBILITY NOTES sTAMv <br /> ON SHEET CS00 <br /> k <br /> 11. PROVIDE MECHANICALLY s <br /> FASTENED INSULATION AT ALL e t <br /> CEILINGS BETWEEN CONDITIONED <br /> AND UNCONDITIONED SPACE, o' <br /> REFER TO SHEET A040 FOR <br /> REQUIRED R-VALUES. <br /> E <br /> 1_5Ha <br /> 12. CORRIDOR VENTILATION CONCEPT <br /> SHOWN,REFER TO DESIGN/BUILD <br /> MECHANICAL PLANS. <br /> 13 F.E.C. RECESSED/FIRE EXTINGUISHER <br /> CABINET <br /> A.a A.e SEE DETAIL: 6 <br /> A311 A051 <br /> 48'-51/2" 21/4" 9'-101/2" 21/4" 46-11" 1" <br /> 14 F.E. SURFACE MOUNTED FIRE <br /> EXTINGUISHER CABINET <br /> 10'-6" 12'-6" 10'-0114" 12'-10" 10,-8" 12'-9" 6'-8112" 5'-101/2" 1" 9'-11" LOCATE PER IBC TABLE 906.3 y <br /> (1)75 FT.MAX.SEPARATION- o <br /> PARKING GARAGE LEVEL ONLY <br /> SEE DETAIL 3/A051 FOR <br /> 5 3 MOUNTING/INSTALLATION <br /> 7A 12 N 7A A412 A412 - 7A HEIGHT <br /> o� 2 M 15. EXIT SIGN PER IBC SECTION 1013. <br /> 8 <br /> 16. REFER TO DESIGN/BUILD p <br /> ELECTRICAL PLANS. <br /> m <br /> 17. REFER TO SHEET A051 FOR <br /> 71 7J 7D PENETRATION REQUIREMENTS IN <br /> 2 II 7D 1 7D -' FIRE RATED CONSTRUCTION. <br /> A410 7A T VC.RRIDORS.A.FT] <br /> 1 18. REFERENCE BUILDING ENVELOPE <br /> II _ DRAWINGS FOR ALL WATERPROOFING. p <br /> INDICATES TYPE A ACCESSIBLE UNIT. o J 19. ALL REMINING UNITS SHALL MEET TYPE <br /> B ACCESSIBLE UNIT I PER BC SECTION 1107.6.y REQUIREMENTS zo <br /> UNIT 4.1 UNIT 3.1 <br /> #2 <br /> LJ 222 ST-2220 UNIT DEMISING WALLS ARE 1 HOUR <br /> SHEET A140 DN SHEET A130 - 3 20 RATED PER IBC SECTION 708 WI1 1. <br /> MINIMUM STC 50.SEE SHEETS A0408„4041 (A° e all c - <br /> Q ° 18 0 21.® INDICATES TYPE'A'UNIT <br /> o = ST GE 7B _ O STORAGE aw <br /> 1 7J v S 03 - - S-2 76 22. AT DOORS INTO ELECTRICAL CONTROL E <br /> Q PANEL ROOMS,SIGNAGE SHALL BE <br /> A.3 11-6 t -_ 2 �1 - - A.3 PROVIDED ON THE DOOR STATING <br /> _a `v _STORAGE 7C CORRIDOR -' 'ELECTRICAL ROOM' o <br /> A411 5-205 21 7C 200 23. AT DOORS INTO FIRE PROTECTION <br /> F.E.C. F.E.C. I EQUIPMENT ROOMS CONTAINING Q 3 c <br /> SPRINKLER RISERS,FACP,OR OTHER c <br /> 7B I— O O II L� OQ SUPPREEDS CONTROLELEMENTS, (n L a " <br /> v S-204 O APPROVED SIGNAGE SHALL BE 4) <br /> A312 2 Q o I I I PROVIDED AND READILY VISIBLE PER Q) � p® <br /> o C� o (� a IFC SECTION 509.1 c <br /> ® p O <br /> O o ° 24. TTWO-WAY COMMUNICATION L w a U N o 3 <br /> a I I yV SYSTEM PER IBC SECTION 1009.8 O <br /> L z <br /> ZI <br /> --- 0 z > <br /> _ r 3 u 0 " FE <br /> -_--_- UNIT 4.1 ___ bNIT3.1 --- UNIT 1A � N O m <br /> NO SHEET A140 S EET1A130 SHEETA110 <br /> 1 7A II I I <br /> (I) 7C <br /> II 7D 7D E <br /> 7D <br /> U <br /> W 7A ri <br /> w c 7A <br /> y <br /> E <br /> OQ 10'-6" 12'-6" 10'-01/4" 12'-10" 9'-11" 10,-8" 12'-9" '-21/2" 10'-0" 3'-21/" PROJECT#: 1827 <br /> 48'-5v2^ 1 46-11^ 2s-11^ 1^ KEY PLAN <br /> N DRAWN BY: AT <br /> gA.a A.e CHECKED BY: ST <br /> so A310 <br /> BLDG A-FLOOR 2 <br /> Ci <br /> WEST <br /> w A211 A <br /> BUILDINGA <br /> Z -LE A-LEVEL 2 WESTA-LEVEL 2 WEST <br /> `/vim/\\I PERMIT SET 10/09/2020 <br /> w <br /> LL 1/8"=T-0" <br />