Laserfiche WebLink
PARKING NOTES <br /> 1. SEE SHEET A001 FOR REQUIRED <br /> PARKING CALCULATIONS. OHNSON BRAUND-- <br /> 2. PARKING STALL SIZE: 15200 52nd Ave.South <br /> a <br /> Suite 300 <br /> Q =8'-0"X 16'-0"MIN. Seattle,WA 98188 <br /> (20 FT.MIN DRIVE AISLE) Phone 206.766.8300 <br /> �S =8'-6"X 18'-6" ARCHITECTURE <br /> (24 FT.MIN.DRIVE AISLE), INTERIOR DESIGN <br /> 3. ACCESSIBLE STALLS: Greg L. illia <br /> Jeffrey A..Williams, <br /> ❑ STANDARD:V-0"MIN WIDTH W/5'-0" <br /> HC ACCESS AISLE ALONG ENTIRE <br /> LENGTH OF STALL. <br /> SEE DETAILS 19/A021 FOR SIGNAGE. <br /> 4. COLUMNS ENCROACH 6"INTO <br /> REQUIRED STALL WIDTH MAX. <br /> 5. ©FUTUR�FQ_RM <br /> L VEHICLE <br /> CHARGRE. <br /> SEE SI <br /> AD NA <br /> SHEET NOTES 8556 <br /> REGISTEREDT ARCHITEC <br /> 1. PODIUM CONSTRUCTION TYPE IA <br /> 2. ALL LEVELS FULLY SPRINKLERED PER <br /> IBC 903.3.1.1(NFPA 13). f FFRFY ARTROR W IJJAM <br /> STATE OF WASHINGTON <br /> 3 REFER TO SHEETS CS03 FOR FIRE <br /> ASSEMBLY KEY PLAN W/WALL TYPE sTunr+ <br /> TAGS 8 LOCATIONS.REFER TO <br /> SHEET SERIES A040 FOR ASSEMBLY <br /> DETAILS. k <br /> 4. 0 INDICATES s m <br /> CONCRETE WALL OR COLUMN PER e t <br /> STRUCTURAL. o <br /> 5. EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> a <br /> ALL VERTICAL SHAFTS SHALL BE 2- .151 <br /> 6' HOUR RATED PER IBC 713.4. <br /> 7. ODOOR TYPE-SEE SCHEDULE <br /> SHEET A100 <br /> A.e A.f A.g A.h A.i A.j A.k A.I <br /> 8. REFER TO SHEET SERIES A100 FOR c <br /> 2 1 UNIT PLAN DOOR&WINDOW <br /> SCHEDULE. - <br /> A412 __________� d <br /> A311 'r 41/4 10'-2" 10'-0" 6 5'-10" 6 9. REFER TO SHEET SERIES A100 <br /> 2 KNOX BOX LOCATION, A500 FOR ENLARGED UNIT PLANS. <br /> 3 <br /> 1B P4._2.I 43:_6" 1D 23'-6" 24'-6" ALLOCATION TO BE r TVP. <br /> FINAL <br /> I RIFTED IN FIELD 10. REFER TO ACCESSIBILITY NOTES <br /> ----� J ON SHEET CS00 <br /> A412 ... VERIFIED 1 16 I <br /> r <br /> r___________ 1I A483 <br /> GARAGE SCREEN GARAGE SCREEN GARAGE SCREEN GARAGESCREEN <br /> A.1 — PROVIDE MECHANICALLY <br /> w I A 1 11 FASTENED INSULATION AT ALL <br /> -01/4" rn I CEILINGS BETWEEN CONDITIONED o <br /> �1 1 SIGNAGE PER SIGNAGE PER AND UNCONDITIONED SPACE, <br /> 11/A021 19/A021 ELIEV# 1 REFER TO SHEET A040 FOR <br /> —_ —_ —_— __ _ _ ELEV- 24— REQUIRED R-VALUES. <br /> A410 <br /> LOCATION OF ELEVATOR 12. CORRIDOR VENTILATION CONCEPT p <br /> \ , SUMP PUMP,SEE SHOWN,REFER TO DESIGN/BUILD a <br /> /1 PLUMBING DRAWINGS <br /> 0" MECHANICAL PLANS. rc <br /> 8'-6" 24 M o <br /> LOB Y <br /> ELEV# <br /> ® ® ELEV-1 002 13. BF.E.C. '5LB ABC'RECESSED/FIRE i <br /> 5'-10" EXTINGUISHER CABINET <br /> — BAN— — — A.2 SEE DETAIL: g <br /> 3.1 <br /> F.E. F.E. A051 <br /> o d 1B N <br /> t <br /> iB 6'-6" 14. F.E. SURFACE MOUNTED'SLB ABC' }t <br /> a 25'-6" 25'-6" 25'-6" 1 45'-0' 35'-55/8"I TIBULE J FIRE EXTINGUISHER CABINET = _ <br /> 008 / LOCATE PER IBC TABLE 906.3 'o <br /> re (1)75 FT.MAX.SEPARATION <br /> N SEE DETAIL 3/A051 FOR �. 5 <br /> 70 UNITS MOUNT AILINSTALLATION ,$€ <br /> __________________________________50 STALLS-____________-_____________________________________________________________________________________________________N _____________ _________1________\101 ' 15 HEIGHT �. <br /> --- r- 4,-0, r- <br /> 1 GARAGE _ EXIT SIGN PER IBC 1013. o <br /> _I ______A411_______ 001 C LLz <br /> _ ________________ ________________---I ___________________— _________ ________ _ 16. REFER ODIESIAN/ LD <br /> N <br /> CAL <br /> __ ______ ________ ___ t � REFER TO DESIGN/BUT <br /> 3c <br /> o- 1 A312 L. 03 0 <br /> O 1 17. REFER TO SHEETA051 FOR <br /> e® <br /> m PENETRATION REQUIREMENTS IN c ry <br /> c o: 8' 6„ 18 FIRE RATED CONSTRUCTION. L. <br /> 1 18 REFERENCE DRAWINGS PORTAL NWATERPROOFING. V N U y G ENVELOPE 0 <br /> w 3� <br /> F.E. F.E. F. - w o_ < zw <br /> N — — — — — — 19. AT DOORS INTO ELECTRICAL CONTROL L ❑ a U w 3 V <br /> =�_= PANEL ROOMS,SIGNAGE SHALL BE a w L z or <br /> _ _ PROVIDED ON THE DOOR STATING O r 3 o m w 3 <br /> m1 25'-6" 25'-6" 25'-6" 20'-6' S'-0" 25'-6" _ _= 'ELECTRICAL ROOM' � N O w o m Fg <br /> DOORS INTO FIRE <br /> O _ _18 = -- 1B 20 EQU PMENT ROOMS CONTAINING <br /> AT <br /> 1 P. '0'MIN. = SPRINKLER RISERS,FACP,OR OTHER <br /> O SUPPRESION CONTROL ELEMENTS, <br /> - APPROVED SIGNAGE SHALL BE <br /> O SIGNAGE PER SIGNALER PROVIDED AND READILY VISIBLE PER <br /> U 191AO21 19/A021 IFC 509.1 <br /> tl <br /> NA.6 24'_0" " I I I I " 24'_6' � I 23'-6" <br /> ip GARAGE SCREEN GARAGE SCREEN 1 1 B GARAGE SCREEN ��� GARAGE SCREEN GARAGE SCREEN iD 1 1B 1 I 11 ST-1 1 <br /> 1 I 1 <br /> _______J L------------J L____________J <br /> I I 1 <br /> " -0 26 54" 91134 _ J11 <br /> A480 PROJECT#: 1827Q fA�11 - / 5'-2" <br /> 142'-s va^ KEY PLAN <br /> DRAWN BY: AT <br /> g A.e A.f A.g A.h A.i A.j A.k A I CHECKED BY: ST <br /> y <br /> BLDG A-GARAGE EAST <br /> Ci <br /> w A210B <br /> BUILDINGA <br /> a (/vim/\�/\I PERMIT SET 10/09/2020 <br /> Z �BLDG A-GARAGE EASTA-GARAGE EAST w <br /> 1 118"=V-0" moommommommoli <br />