Laserfiche WebLink
2025 PAVEMENT MAINTENANCE OVERLAY SPECIAL PROVISIONS <br />PW# 3830 <br /> SP-79 March 26, 2025 <br /> <br />8-20.GR8 1 <br />Illumination, Traffic Signal Systems, Intelligent Transportation Systems, and 2 <br />Electrical 3 <br /> 4 <br />8-20.2.GR8 5 <br />Materials 6 <br /> 7 <br />8-20.2.INST1.GR8 8 <br />Section 8-20.2 is supplemented with the following: 9 <br /> 10 <br />CNH 8-20.2(9-29.3(2)) DETECTOR CABLE.DOCX 11 <br />Fiber Optic Cable, Electrical Conductors, and Cable 12 <br /> 13 <br />Section 9-29.3 is supplemented with the following: 14 <br /> 15 <br />9.29.3(2)F Detector Loop Wire 16 <br /> 17 <br />Section 9-29.3(2)F is revised to read as follows: 18 <br /> 19 <br />(******) 20 <br />Detector loop wire for round loops shall use 14 AWG stranded copper 21 <br />conductors, and shall conform to IMSA Specification 51-7, with cross-linked 22 <br />polyethylene (XLPE) insulation encased in a polyethylene outer jacket (PE 23 <br />tube). 24 <br /> 25 <br />(******) 26 <br />9.29.3(2)J Loop Detector Lead-In Cable (New Section) 27 <br /> 28 <br />Loop Detector Lead-In Cable (1 pair) 29 <br /> 30 <br />Two conductor shielded #14 AWG lead-in cable conforming to IMSA 31 <br />Specification #50-2-1984 shall be installed where shown in the wiring schedule 32 <br />in the Plans. Where existing loop lead-in cable is present, the existing cable shall 33 <br />be pulled out and disposed of. The new lead-in cable shall be spliced to the loop 34 <br />wires utilizing Buchanan splice caps and crimper and a scotch cast epoxy 82-35 <br />B1 splice kit or approved equal as detailed in City Standard Drawings 806A, B 36 <br />and C. Where the wiring schedule in the plans calls for more than one loop 37 <br />detector to be spliced into a single lead-in cable, the loops shall be wired in 38 <br />series. The loop detector lead-in cable shall be pulled into the controller cabinet 39 <br />and connected to the detector channel terminals as indicated in the loop detector 40 <br />schedule in the plans. 41 <br /> 42 <br />Loop Detector Lead-In Cable (2 or 3 pair) 43 <br /> 44 <br />Two or three pair loop detector lead-in cable shall be installed where shown in 45 <br />the wiring schedule in the plans. Belden 1037A and 1055A cables are a pre-46 <br />approved source. Other cables may be submitted for approval consistent with 47 <br />the following specifications: Multi pair loop detector lead-in cable shall consist of 48 <br />two or three individually twisted and shielded pairs of #16 AWG stranded copper 49 <br />wire, surrounded by an outer jacket of polyvinyl chloride (PVC). Each pair shall 50 <br />also contain a stranded copper drain wire and shall be individually shielded with 51 <br />an aluminum polyester foil shield. 52