Laserfiche WebLink
-qqw ZAP ENERGY <br /> I <br /> ZRD-SPL-001 <br /> Table 4 Occupancies of the locations and the distances from the area to the FUZE source. <br /> Dose limit for <br /> Label on Distance to the shielding Annual dose <br /> Location Description Type of Area Occupancy <br /> the map FuZE source (m) design (mrem/y) <br /> (mrem/y) <br /> 1 East wall - North Unrestricted 5% 18.9 2000 0.4 <br /> 2 East wall - FuZE-Q location Unrestricted 5% 18.2 2000 0.2 <br /> 3 East wall - Emergency exit Unrestricted 5% 20.2 2000 1 <br /> HV Lab South <br /> 4 (Outside the windows) Unrestricted 5% 21.3 2000 3 <br /> 5 HV South (Outside the door) Unrestricted 5% 19.5 2000 4 <br /> 6 Control Room Controlled Area 100% 13.7 100 11 <br /> 7 Building North (Bay doors) Unrestricted 5% 10.8 2000 6 <br /> Building North <br /> 8 Unrestricted 5% 19.4 2000 1 <br /> (Roll up door/emergency exit) <br /> 9 Machine shop Unrestricted 100% 10.4 100 18 <br /> 10 HV Lab Unrestricted 50% 17.3 200 5 <br /> 11 Technician area Unrestricted 100% 12.5 100 12 <br /> 12 Suite 101 offices Unrestricted 100% 16.0 100 7 <br /> 13 Vacuum Parts Preparation Room Unrestricted 50% 13.0 200 12 <br /> 14 Neutronics Lab Controlled Area* 20% 13.9 500 11 <br /> 15 Suite 100 offices Unrestricted 100% 19.1 100 5 <br /> 16 Roof Unrestricted 5% 8.7 2000 21 <br /> * Controlled area for control of radioactive materials <br /> Zap Energy Inc. Proprietary Information <br /> 18 <br />