Laserfiche WebLink
4 <br /> 10" <br /> CUT TOP FLANGE OF <br /> JOIST(AS NEEDED)TO K <br /> DIAPHRAGM EDGE <br /> INSTALL CONT LEDGER TAN <br /> � <br /> SCREW SHIELDING PER PLAN (E)CONC WALL ,_.• SHIELDING PER PLAN <br /> SHIELDING PER PLAN PER PLAN a GAP 1 l waiter <br /> PER EDGE SCREW ROOFSHEATHING ROOF Anny p moore <br /> ROOF SHEATHING PER PLAN ROOF SHEATHING CONT LEDGER PLAN, PER PLAN EDGE SCREW J. SHEATHING <br /> PER PLAN USE SLOTTED CONNECTION GAP PER PLAN lift <br /> h 14'-0" PER SECTION A-A ON 1/S-31Q 1N-0",� h 14'-0" <br /> 5/8'HILTI KB-TZ2 WEDGE Y Walter P Moore and Associates,Inc. <br /> RIM TRACK W/#10 ANCHOR W/4 1/2"NOM <br /> SMS EA FLANGE EMBED @ 32"OC FIELD SCREW 203 North LaSalle Street,Suite 2100 <br /> EA JOIST Chicago,IL 60601 <br /> TRACK <br /> CONT WALL TOP ROOF JOIST PER PLAN BLOCKING MATCH Sl8"HILTI KB-TZ2 WEDGE <br /> ROOF JOIST PER PLAN CONT WALL TOP ROOF JOISTS,TYP ANCHOR WITH 4 1/2"NOM <br /> TRACK a < EMBED @ 32"OC 4"MIN <br /> SEE SECTION A-A 8"MAX ROOF JOIST <br /> 1�2'-0" h 12 __ PER PLAN TYP <br /> (E)CONIC ,WALL PER PLAN 312.260.2900 <br /> F7t <br /> HEADER PER DETAIL 3/S300 ROOF JOIST PER PLAN <br /> (E)CEILING JOIST LEDGER PER PLAN TYPICAL JOIST <br /> (E)CEILING JOIST,TYP - BRIDGING Project Name <br /> STUD WALL PER PLAN <br /> WALL JAMB <br /> (E)STUD WALL BEYOND -® 6" <br /> 5/8"GYPSUM BOARD BEYOND TYP N LEDGER PER PLAN <br /> L4x4z1/2"XO'-6"W/(2)5/8" <br /> WALL SHEATHING PER PLAN WALL SHEATHING PER HILTI KB-TZ WEDGE 2"LONG SLOTTED HOLE, <br /> PLAN(BEYOND) ANCHOR W/4 112"NOM —— — MATCH DIAMETER OF N V5 - ZAP <br /> 5/8"GYPSUM BOARD - °® ® ° EMBED,TYP EA ROOF SHEATHING EDGE SCREW <br /> NOTES: <br /> (E)STUD WALL 1 1/2" JOIST EDGE OF ROOF SHEATHING ENERGY <br /> 1. FOR ITEMS SHOWN AND NOT SPECIFIED SEE DETAIL 3/S-310 TYP 3/8"BOLT IN 2"LONG (E)CONCRETE WALL <br /> NOTE: SLOTTED HOLE IN <br /> 2. SEE"C"ON 4/S-303 FOR TYPICAL FRAMING DETAIL SECTION A-A ANGLE FLANGE PER SECTION A-A <br /> REFER TO"C"ON 4/S-303 FOR TYPICAL FRAMING DETAIL <br /> SECTION A-A ON 1/S-310 <br /> FRAMING DETAIL FRAMING DETAIL ^/ FRAMING DETAIL CONNECTION TO CONCRETE WALL client: <br /> 4 3/4" 3/4"=1'-0" WPM RESPONSE: <br /> WE WILL UPDATE THIS <br /> The ceiling HDPE should come all DETAIL. ZAP ENERGY <br /> the way out and square off with the <br /> wall HDPE as shown in green. <br /> (E)CONIC WALL BEYOND <br /> Keyplan <br /> STRAPPER PLAN <br /> 1" OOF SHEATHING SHIELDING PER PLAN <br /> GAP BEAM PER PLAN PER PLAN <br /> 1� <br /> a RIM TRACK W/#10 SMS <br /> EA FLANGE EA JOIST <br /> ROOF JOIST TRACK <br /> WALL TOP Issues/Revisions <br /> SIMPSON HDU6 W/(12) <br /> PER PLAN TRACK <br /> #14SMS ISSUE FOR PERMIT <br /> 5/8"THREADED ROD IN 8 <br /> 1/2"DEEP HOLE FILLED (E)CEILING JOIST <br /> W/HILTI HIT-HY 200 V3 No. Date Description <br /> EPDXY ADHESIVE AND 1 10/09/24 ISSUE FOR PERMIT <br /> MINIMUM DISTANCE OF I STUD WALL PER PLAN <br /> 7"TO EDGE OF WALL <br /> (E)STUD WALL <br /> Only Required at Back WALL SHEATHING PER PLAN <br /> I 8 Change to wedge or <br /> drot0 Back Stud Locations? and ananchorepoxy <br /> L anchor requires carts, <br /> and additional <br /> inspection vs std from NOTES: <br /> NOTE: City. 1. FOR ITEMS SHOWN AND NOT SPECIFIED SEE DETAIL 31S-310 <br /> SEE DETAIL 2/S-310 FOR ITEMS SHOWN AND NOT SPECIFIED 2. SEE"C"ON 4/S-303 FOR TYPICAL FRAMING DETAIL <br /> FRAMING DETAIL FRAMING DETAIL <br /> 6 <br /> e <br /> `yy Project Number. Drawn By <br /> �I <br /> D24.24007.00 GB/MC <br /> Approved By: Checked By: <br /> w` <br /> WPM RESPONSE: OL OIL <br /> a NO WEDGE ANCHOR HAS ENOUGH Certifcation Statement <br /> CAPACITY FOR THIS CONFIGURATION, TO THE BEST OF THE ENGINEER'S KNOWLEDGE, <br /> WE ARE REVIEWING OPTIONS THAT DO THE PLANS AND SPECIFICATIONS COMPLY WITH <br /> z NOT REQUIRE EPDXYANCHORS <br /> THE APPLICABLE MINIMUM BUILDING CODES. <br /> Seal and Signature <br /> oc 7(F <br /> O of wASR <br /> o <br /> i r <br /> 2 E p 8.04.2025 <br /> P� RAL EN��G�¢ <br /> of NALFN <br /> 1 4 <br /> o Copyright(c)2024 by Walter P.Moore and Associates,Inc. <br /> This document and the information herein is the property of Walter P. <br /> m Moore and Associates,Inc.No part hereof shall be copld, <br /> Eduplicated,distributed,disclosed or used to any extent whatsoever <br /> xcepl as expressly authorized by Waiter P.Moore and Associates, <br /> im,Any person,firm,or <br /> on <br /> however obtained,shall by virtual hereof,Ibe deemed to have agreed <br /> to the forgoing restrictions and that this document will be held in trust <br /> and confidence subject only to the private use expressly authorized <br /> by Walter P.Moore and Associates,Inc. <br /> W <br /> c. Drawing Title <br /> z <br /> g FRAMING <br /> DETAILS <br /> 0 <br /> x <br /> Sheet No. <br /> S-310 <br />