Laserfiche WebLink
HP8 with common ERV DOAS Input Data <br />Project Name: EVE —ZAP ENERGY-v5-11 10/22/2024 <br />Prepared by: HERMANSON COMPANY LLP 11:17AM <br />1. General Details: <br />Air System Name HP8 with common ERV DOAS <br />Equipment Type......................................................................................... Terminal Units <br />Air System Type Variable Refrigerant Flow (VRF) <br />Numberof zones ..................................................................................................... 4 <br />Ventilation Dedicated Outdoor Air System <br />2. Dedicated Outdoor Air System Components: <br />Ventilation Air Data: <br />Airflow Control <br />Constant Ventilation Airflow <br />Ventilation Sizing Method ...................................................... <br />ASHRAE Std 62.1-2016 <br />Unocc. Damper Position <br />Closed <br />DamperLeak Rate................................................................................................................. <br />0 % <br />Outdoor Air CO2 Level <br />400 ppm <br />Ventilation Reclaim Data: <br />Reclaim Type......................................................................... Sensible and Latent Heat <br />Thermal Efficiency 50 % <br />InputkW ..................................................................................................... 0.100 kW <br />Schedule JFMAMJJASOND <br />Ventilation Fan Data: <br />Fan Type Forward Curved <br />Configuration ...................................................................................................... Draw-thru <br />Fan Performance 1.25 in wg <br />OverallEfficiency................................................................................................................. 54 % <br />Airflow <br />100 <br />1 90 <br />1 80 <br />1 70 <br />1 60 <br />50 <br />% kW <br />100 <br />1 91 <br />1 81 <br />1 72 <br />1 61 <br />54 <br />Airflow, <br />40 <br />1 30 <br />20 <br />10 <br />0 <br />% kWJ <br />46 <br />1 40 <br />33 <br />27 <br />21 <br />Duct System Data: <br />Return Duct or Plenum Data: <br />Return Air Via .......................................... ........ Ducted Return <br />3. Zone Components: <br />Space Assignments: <br />Zone 1: IDU-104 <br />ZAP -OFFICE 3 <br />x1 <br />Zone 2: IDU-105 <br />ZAP -OFFICE 4 <br />x1 <br />Zone 3: IDU-103 <br />ZAP -OFFICE 3 <br />x1 <br />Zone 4: IDU-104 <br />ZAP -OFFICE 4 <br />x1 <br />Thermostats and Zone Data: <br />Zone <br />Cooling T-Stat <br />Occ. <br />('F) <br />Cooling T-Stat <br />Unocc. <br />('F) <br />Heating T-Stat <br />Occ. <br />('F) <br />Heating T-Stat <br />Unocc. <br />('F) <br />T-Stat <br />Throttling <br />Range <br />('F) <br />1 <br />75.0 <br />85.0 <br />72.0 <br />55.0 <br />1.00 <br />2 <br />75.0 <br />85.0 <br />72.0 <br />55.0 <br />1.00 <br />3 <br />75.0 <br />85.0 <br />72.0 <br />55.0 <br />1.00 <br />4 <br />75.0 <br />85.0 <br />72.0 <br />55.0 <br />1.00 <br />Thermostat Schedule 90.1 Office Thermostat <br />Unoccupied Cooling is............................................................... Available <br />Common Terminal Unit Data: <br />Cooling Coil: <br />Hourly Analysis Program 5.11 Page 1 of 3 <br />