Laserfiche WebLink
HP8 with common ERV DOAS Input Data <br />Project Name: EVE —ZAP ENERGY-v5-11 10/22/2024 <br />Prepared by: HERMANSON COMPANY LLP 11:17AM <br />Design Supply Temp. 55.0 °F <br />CoilBypass Factor............................................................................................ 0.100 <br />Cooling Source Air -Cooled DX <br />Schedule-------------------------------------------------------------------------------------------------- JFMAMJJASOND <br />Heating Coil: <br />Design Supply Temp. 86.9 °F <br />Heating Source.......................................................................... Air Source Heat Pump <br />Schedule JFMAMJJASOND <br />Fan Control <br />Terminal Units Data: <br />Cycled <br />Air <br />Distribution <br />Air <br />Design <br />Air <br />Effectiveness <br />Distribution <br />Fan <br />Supply <br />Zone <br />Terminal Type <br />Distribution <br />Specification <br />Effectiveness <br />Minimum Airflow <br />Fan Performance <br />Efficiency <br />Temp. <br />1 <br />Fan coil <br />Ceiling supply / <br />ASHRAE 62.1 <br /><auto> <br />0.30 CFM/ft2 <br />0.50 in wg <br />70 % <br />ceiling return <br />2 <br />Fan coil <br />Ceiling supply / <br />ASHRAE 62.1 <br /><auto> <br />0.30 CFM/ft2 <br />0.50 in wg <br />70 % <br />ceilingreturn <br />3 <br />Fan coil <br />Ceiling supply / <br />ASHRAE 62.1 <br /><auto> <br />0.30 CFM/ft2 <br />0.50 in wg <br />70 % <br />ceilingreturn <br />4 <br />Fan coil <br />Ceiling supply / <br />ASHRAE 62.1 <br /><auto> <br />0.30 CFM/ft2 <br />0.50 in wg <br />70 <br />ceiling return <br />4. Sizing Data (Computer -Generated): <br />System Sizing Data: <br />Sizing Data: <br />Hydronic Sizing Specifications: <br />Chilled Water Delta-T----------------------------------------------------------------------------------------------------- <br />10.0 °F <br />Hot Water Delta-T <br />30.0 °F <br />Safety Factors: <br />CoolingSensible..................................................................................................................... <br />0 % <br />Cooling Latent <br />0 % <br />Heating...............................................................................................................15 <br />% <br />Zone Sizing Data: <br />Zone Airflow Sizing Method Sum of space airflow rates <br />Space Airflow Sizing Method ..................................... Individual peak space loads <br />5. Equipment Data <br />VRF Outdoor Unit - Heat Pump <br />Performance Data - Cooling <br />Equipment Sizing <br />Auto -Sized <br />DesignOADB ............................................................ <br />................. 95.0 <br />°F <br />Capacity Oversizing Factor <br />0 <br />% <br />AHRI Performance Rating <br />10.800 <br />EER <br />Performance Data - Heating <br />Equipment Sizing <br />Auto -Sized <br />DesignOADB............................................................................................................... <br />47.0 <br />°F <br />Capacity Oversizing Factor <br />0 <br />% <br />AHRI Performance Rating.............................................................................................3.30 <br />COP <br />System Data <br />Compressor Type Variable Speed Scroll <br />MinimumLoad................................................................................... ..................10 % <br />Refrigerant Piping Equivalent Length 0.0 ft <br />Refrigerant Piping Vertical Rise.....................................................................................0.0 ft <br />Heat Pump Data: <br />Heat Pump Cutoff OADB -4.0 °F <br />HeatRecovery Used.......................................................................................................... No <br />Auxiliary Heating Type Electric Resistance <br />Auxiliary Heating Upper Cutoff.................................................................................... 70.0 °F <br />Hourly Analysis Program 5.11 Page 2 of 3 <br />