Drew Martin <br />From: Drew Martin <br />Sent: Thursday, June 30, 2022 4:59 PM <br />To: jason@vanderbeken-remodel.com' <br />Subject: City of Everett Permit Services: 310 E Viewridge Drive (B2206-008) - First Building Intake <br />Review <br />Attachments: 2018 IRC-Typical Code References_04-12-2021.docx; CoE_Residential Drawing <br />Preparation -Edited 09-27-2021.pdf <br />Hello, Jason. <br />Your application has been received and a permit set up. However, the submitted documents are not <br />sufficiently developed for us to perform a comprehensive review at this time. <br />Information is attached to provide guidance. Revised construction -level documents should be submitted for <br />review. Two complete sets of the revised drawings should be submitted to replace the previously submitted <br />drawing sets. Preliminary comments are provided below to assist in preparing the drawings, but these are not <br />intended to provide a comprehensive review. The resubmittal documents should include an itemized <br />response letter clarifying how the review comments below have been addressed. Depending on your <br />experience with the adopted codes and preparing documents, we recommend consulting with a design <br />professional to assist you. <br />Intake Review Comments: <br />General: <br />1. Unpermitted work has occurred at the house that is not shown in the construction drawings, including but <br />not limited to modifications to the roof construction and supporting load paths (e.g., walls, beams, etc.) <br />and the new and existing decks. The drawings should be revised to show all previous unpermitted work as <br />new work; all new work is required to comply with the current code requirements. See IRC Sections <br />R102.7.1, R105.1, and R113.1. <br />2. The construction drawings should include all levels of the house. Detailed construction information is not <br />required for areas that are not included in the proposed scope -of -work. At a minimum, the plans should <br />show the walls, doors, egress routes, windows including egress windows, smoke and CO alarms, and use of <br />each room. See IRC Section R106.1.1. <br />Architectural: <br />3. The Main Floor walls appear to impact the head clearance for the stairs. The conditions at the stairs <br />should be shown in the drawings. See IRC Section R311.7. <br />4. The project includes exposing the exterior envelope cavities for the entire building. The building is <br />required to be insulated per WSEC Section R503.1.1. Where required, insulation complying with current <br />code should be provided per Table R402.1.1. Attics should be provided with ventilation baffles per Section <br />R402.2.3. <br />