Laserfiche WebLink
10/10/2023 Christopher Post Frame Buillding B2308-045 r <br /> TSE page: !a <br /> Engineering <br /> EMBEDDED_POST_DESIGN (POST-FRAME CONSTRUCTION) <br /> Sidewall <br /> Eave Height Post b Post d HF Post Fb Fc E 10 ^6 <br /> 9 NOMINAL: 4 6 #2 850 1300 1.3 <br /> ft. ACTUAL: 3.5 5.5 CD 1.6 1.6 1.0 <br /> in. in- CF 1.3 1.1 <br /> CL 1 <br /> Bay Width Span Roof OH Roof D Roof S Ci 0.8 0.8 0.95 <br /> 12 24 1.5 7 25 <br /> ft. ft. ft. psf psf Fb' Fc* EI(10)A6 <br /> 1414 1830 1.235 <br /> ASD Wind Pressure 0.75W W Is Iw psi psi psi <br /> 10 90 120 1 1 <br /> psf plf pif Cs <br /> 1 <br /> IBC 2018 ASD BASIC LOAD COMBINATIONS: <br /> Loading: D+ 0.75S+ 0.75W Loading: D+W <br /> P 4172lbs. P 1134lbs. <br /> fc 216.7 psi fc 58.9 psi <br /> le 86.4 in. le 86.4 in. <br /> le/d 15.7 Ie/d 15.7 <br /> KCE 0.3 - __-- __ K 0.3 - <br /> FCE 1501 psi FCE 1601 psi <br /> c 0.8 c 0.8 <br /> k.1 1.14 k.1 1.14 <br /> k.2 1.03 k2 1.03 <br /> Cp 0.62 Cp 0.62 <br /> Fc' 1133 psi Fc' 1133 psi <br /> M (in-span) 6151 inAbs. M (in-span) 8201 inAbs. <br /> M (base) 10935 inAbs. M (base) 14580 inAbs. <br /> S.Mod. 17.66 in^3 S.Mod. 17.65 in^3 <br /> fb(in-span) 349 psi fb(in-span) 465 psi <br /> fb(base) 620 psi fb(base) 826 psi <br /> Post CSI (in-span)= 028 Post CSI (in-span)= 0.33 <br /> Post CSI (base)= 0.55 Post CSI (base)= 0.61 <br /> Use P.T.4x6 HF#2 <br /> v 6.9.07 <br /> L City of Everett Permit Review <br /> EVERETT Status:Approved <br /> 10/11/2023 11:50:19 AM <br /> Page 10 of 16 These Plans Shall remain on Job Site Barrie Kenning,Plans Examiner <br />