Laserfiche WebLink
10/10/2023 Christopher Post Frame Buillding B2308-045 <br /> TSE page: j <br /> Engineering <br /> EMBEDDED POST DESIGN (POST-FRAME CONSTRUCTION) <br /> Endwall <br /> Eave Height Post b Post d HF Post Fb Fe E0 MAIS <br /> 9 NOMINAL: 4 6 #2 850 1300 1.3 <br /> ft. ACTUAL: 3.5 5.5 C 1.6 1.6 1.0 <br /> in_ in. CF 1.3 1.1 <br /> CL 1 <br /> Av.Spacinq Bay Width Roof OH Roof D Roof S Ci 0.8 0.8 0.95 <br /> 12 12 1.5 7 25 <br /> ft. ft. ft. psf psf Fb' Fc" E' 10 A6 <br /> 1414 1830 1.235 <br /> ASD Wind Pressure 0.75W W Is Iw psi psi psi <br /> 10 90 120 1 1 <br /> psf pif plf Cs <br /> 1 <br /> IBC 2018 ASD BASIC LOAD COMBINATIONS: <br /> Loading: D+0.75S+ 0.75W Loading: D +W <br /> P 2318lbs. P 630lbs. <br /> fo 120.4 psi fc 32.7 psi <br /> le 86.4 in. le 86.4 in. <br /> le/d 15.7 le/d 15.7 <br /> KCE -0.3 KCE 0.3 <br /> FCE 1501 psi FCE 1501 psi <br /> C 0.8 C 0.8 <br /> k.1 1.14 k.1 1.14 <br /> k.2 1.03 k.2 1.03 <br /> Cp 0.62 Cp 0.62 <br /> Fc' 1133 psi Fc' 1133 psi <br /> M (in-span) 6151 inAbs. M (in-span) 8201 inAbs. <br /> M (base) 10935 inAbs. M (base) 14580 inAbs. <br /> S.Mod. 17.65 in13 S.Mod. 17.65 in^3 <br /> fb(in-span) 349 psi fb (in-span) 465 psi <br /> fb(base) 620 psi fb(base) $26 psi <br /> Post CSI (in-span)= 0.26 Post CSI (in-span)= 0.33 <br /> Post CSI (base)= 0.49 Post CSI (base)= 0.60 <br /> Use P.T.4A HF#2 <br /> v 6,9.07 <br /> L City of Everett Permit Review <br /> EVERETT Status:Approved <br /> 10/11/2023 11:50:19 AM <br /> Page 11 of 16 These Plans Shall remain on Job Site Barrie Kenning,Plans Examiner <br />