Laserfiche WebLink
b. Limit total area of windows for each side of the building per IRC Table R302.1(1) or R302.1(2). <br /> c. Show location, size, and bottom sill height of all windows. <br /> d. Provide emergency escape windows in sleeping rooms (IRC Section R310). <br /> e. Safety glazing should be specified where required per IRC Section R308.4. <br /> f. Fall protection should be provided when required per Section R312.2.1. <br /> 9. Stairs (IRC Section R311.7): <br /> a. Minimum 36-inch width (IRC Section R311.7.1). <br /> b. Landings (IRC Section R311.7.6). <br /> c. Handrails (IRC Section R311.7.8). <br /> d. Guards (IRC Section R312.1). Limit openings per Section R312.1.3. <br /> e. Enclosed spaces under stairs shall be covered with minimum 1/2"gypsum board (IRC Section <br /> R302.7). <br /> f. Artificial lighting (IRC Section R303.7). <br /> 10. Smoke Alarms (IRC Sections R314.2.2(WAC) <br /> Smoke alarms should be interconnected per Section R314.5. Combination alarms are permitted per <br /> Sections R314.5 and R315.4. <br /> 11. Carbon Monoxide Alarms ( R315.2.2(WAC). <br /> In order for the processing of your application to continue, it will be necessary to provide the Building <br /> Division with two new sets of revised construction documents reflecting the corrections requested. Please <br /> include a response letter which indicates how the corrections were resolved. <br /> These initial comments are general in nature and based on preliminary information. Additional comments <br /> will typically be generated once a complete submission is reviewed. All comments are based on the 2018 <br /> International Building Code (IBC), 2018 International Residential Code (IRC), and/or the 2018 <br /> Washington State Residential Energy Code (WSEC), as amended by the State of Washington and adopted <br /> by the City of Everett. <br /> These comments address building issues only. Additional revisions or additions may be required by other <br /> departments (such as Utilities, Traffic, Planning or Fire). All required submittals must be of sufficient detail <br /> and information to ensure that the proposed structure will be constructed in compliance with all adopted <br /> codes. <br /> Sincerely, <br /> Matt Schreifels <br /> Building Inspector <br /> Phone: 425-257-8810 <br /> Email: mschreifels@everettwa.gov <br /> S:\MSchreife1s\2024\P1an Review 2024\B2311-004_1111 WetmoreAve\B2311-004 1st IL(2024.01.10).docx <br /> 3200 Cedar Street © 425.257.8810 PermitServices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />