ix. Smoke and carbon monoxide alarms. <br /> B. Architectural Requirements <br /> 1. General: <br /> a. Plans: Floor, basement, reflected ceiling, and roof. <br /> b. Exterior elevations: Show each side of building where work is occurring. May be omitted if <br /> exterior work is not proposed. <br /> c. Building sections: Provide complete sections through building to clarify proposed construction. <br /> Minimum one in each principal building direction (more as required). May be omitted for small <br /> projects and renovations. <br /> d. Local sections, details, general notes, material requirements, and other information as required to <br /> specify the proposed construction. <br /> e. Plan and elevation dimensions: Include all dimensions, elevations, slopes, etc. required to define <br /> the proposed work. <br /> 2. Rooms (IRC Sections R304 and R305): <br /> a. Label use of each room. <br /> b. Room dimensions and area <br /> c. Ceiling height(s) and slope(s). <br /> 3. Bedrooms (IRC Section R304 and R305): <br /> a. Minimum 70 SF. <br /> b. Minimum 7 feet wide in any direction. <br /> c. Minimum 7-foot ceiling height. <br /> d. Minimum one emergency escape opening (IRC Section R310.1(WAC)). <br /> 4. Kitchens: <br /> a. Minimum one required (IRC Sections R306.2). <br /> b. Minimum Ceiling height of 7'-0"(IRC R305.1) <br /> c. Provide permanent provisions for cooking (IRC Section R202) <br /> d. Provide local exhaust (IRC Section R303.4(WAC) and M1505.4.4(WAC)). <br /> 5. Bathrooms: <br /> a. Layouts to comply with IRC Section R307.1(WAC). <br /> b. Bathtub and shower spaces to have non-absorbent surface for 6-foot height (IRC Section <br /> R307.2). <br /> c. Local exhaust fans (IRC Sections 303.4 and M1505.4.4(WAC)). Where bathroom fixtures are <br /> compartmentalized, provide separate fans in each space. <br /> 6. Hallways: <br /> a. Minimum 3 feet wide (IRC Section R311.6). <br /> b. Minimum 7-foot ceiling height (IRC Section R305.1). <br /> 7. Doors: <br /> a. The location, type, size, and swing or sliding direction (IRC Section R106.1.1). <br /> b. Minimum 6'-8"clear opening (IRC Section R305.1). <br /> c. Egress doors and landings per IRC Sections R311.1 through R311.3. <br /> d. Doors should not swing over stairs (Section R311.7.6). <br /> 8. Windows: <br /> a. Provide windows per IRC Section R303.1 except where compliant artificial light is provided. <br /> 3200 Cedar Street © 425.257.8810 Permit5ervices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />