Laserfiche WebLink
MECHANICAL DEMOLITION SITE PLAN <br />MD1.01 SCALE: 1" = 30' <br />JTE <br />-1/4"CW <br />Q 2 MONTE CRISTO ANNEX DEMOLITION SITE PLAN <br />MD1.01 SCALE: 1/8" = 1' 0" <br />SHEET NOTES: <br />1. DEMOLITION WORK SHOWN BASED ON RECORD DRAWINGS. NOT <br />ALL EXISTING PIPING, DUCTS, AND EQUIPMENT IS SHOWN. <br />CONTRACTOR TO VERIFY EXACT LOCATION, QUANTITIES, AND <br />SIZES PRIOR TO BEGINNING WORK. NOTIFY A/E OF ANY <br />DISCREPANCIES PRIOR TO COMMENCING WORK. <br />2. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED FOR <br />SUPPORT DURING DEMOLITION AND CONSTRUCTION. <br />3. ALL EXISTING PIPING, DUCTS, AND EQUIPMENT SHALL REMAIN <br />UNLESS OTHERWISE NOTED. <br />4. REFER TO M-900 SERIES SHEETS FOR STANDARD DEMOLITION <br />DETAILS NOT REFERENCED ON PLANS. COMPLY WITH ALL <br />REQUIREMENTS IN DETAILS. <br />5. PROVIDE CAPPED PIPE AT ALL ABANDONED PIPE TERMINATIONS. <br />REFERENCE CAPPED PIPE DETAIL FOR ADDITIONAL INFORMATION <br />6. ITEMS FOR REMOVAL ARE INDICATED TO ESTABLISH GENERAL <br />SCOPE OF DEMOLITION. CONTRACTOR SHALL VERIFY EXISTING <br />CONDITIONS IN THE FIELD AND PROVIDE ADDITIONAL DEMOLITION <br />AS NECESSARY TO COMPLETE AND COORDINATE THE WORK. <br />REFER TO MECHANICAL DEMOLITION SPECS FOR ADDITIONAL <br />REQUIREMENTS <br />FLAG NOTES: <br />DEMOLISH EXISTING UNDERGROUND PIPING TO LOCATION <br />NOTED AND PATCH AND SEAL ANY PENETRATIONS IN <br />UTILIDOR WALLS. CAP UNUSED PIPES TO BE ABANDONED <br />UNDERGROUND. PREPARE FOR STEAM AND CONDENSATE <br />CONNECTIONS IN NEW WORK. <br />PROVIDE NEW 3"CONDENSATE PIPING AT THIS LOCATION TO <br />MAINTAIN EXISTING LOOP OPERATION. REMOVE ALL TEE <br />FITTINGS FROM PIPING. <br />PROVIDE NEW 4"STEAM PIPING AT THIS LOCATION TO <br />MAINTAIN EXISTING LOOP OPERATION. REMOVE ALL TEE <br />FITTINGS FROM PIPING. <br />MITHUN <br />SEATTLE I Pi., 55, 1201 Alaskan WW'#200 <br />Ssama WA 991011206.623.3344 <br />SAN FRANCISCO I860 MaAet St-, #300 <br />San F-d—, CA 941041415.956.008 <br />LOS ANGELES 15837 Adams Blvd <br />UN., City, CA 902321323.07.2150 <br />Wflmn.com <br />H A R G I S <br />t aaaauns . Nro- <br />PROJECT <br />Monte Cristo Hall and <br />Annex Demolition <br />LOCATION <br />2000 Tower Street <br />Everett, WA 98201 <br />PREPARED FOR <br />Everett Community <br />College <br />HARGIS <br />BC <br />w Ea <br />PCC min 1 <br />PaEass. <br />RR <br />PRR aEnaaaa <br />ec <br />6577 <br />REGISTERED <br />ARCIiITECT <br />WALTE7 '3C HAC HT <br />STATE OF WASHINGTOk <br />MECHANICAL <br />DEMOLITION SITE <br />PLAN <br />19099 <br />28 NOVEMBER 2022 <br />MD1.01 <br />PERMIT SET <br />C 2016 MITHUN, INC. <br />NnT FnR CUMSTRl1CTIDN <br />