Laserfiche WebLink
GENERAL <br />EXISTING MECHANICAL TO BE <br />REMOVED <br />EXISTING MECHANICAL TO <br />REMAIN <br />NEW MECHANICAL WORK <br />MATCHLINE OR PROPERTY <br />LINE <br />- - - - - - - - - <br />ENLARGED PLAN BOUNDARY <br />1 <br />M1.01 <br />DETAIL/PLAN IDENTIFIER <br />A <br />M1.01 <br />SECTION IDENTIFIER <br />A <br />ELEVATION IDENTIFIER <br />REVISION DEFINITION AREA, <br />AREA ENCIRCLED CONTAINS <br />CHANGES MADE SUBSEQUENT <br />TO PREVIOUS ISSUE <br />0 <br />REVISION CALLOUT <br />FLAG NOTE CALLOUT <br />O <br />DEMOLITION NOTE TAG <br />O <br />EQUIPMENT TAG <br />AHUA7 <br />MECHANICAL EQUIPMENT TAG <br />1 <br />AHU <br />MECHANICAL EQUIPMENT TAG <br />�N <br />NORTH ARROW <br />C),LOCATION <br />WHERE PICTURE <br />WAS TAKEN AND DIRECTION <br />INVERT ELEVATION OR POC <br />ELECTRICAL PROVISIONS FOR MECHANICAL WORK <br />Ch <br />LOCATION OF STARTER, <br />DISCONNECT & CONTROLS <br />vFo <br />VARIABLE FREQUENCY DRIVE <br />HT HT <br />HEAT TRACE BETWEEN <br />r <br />SYMBOLS OR END OF RUN <br />ACCESS, EXCAVATION, AND BACKFILLING <br />ACCESS DOOR (SPECIFIED OR <br />AS SHOWN ON DWGS) <br />- - MECHANICAL ACCESS <br />(SPECIFIED OR AS SHOWN ON <br />DWGS) <br />PIPING <br />PIPE ELBOW UP OR PIPE TEE <br />UP AND DOWN <br />PIPE ELBOW DOWN <br />PIPE TEE UP <br />PIPE TEE DOWN <br />0 PIPE RISE <br />PIPE CAP <br />4 PIPE PLUG <br />�- FLOW DIRECTION <br />PIPE BREAK <br />PIPE CONNECTION <br />VALVES <br />VALVE: GATE, BALL, <br />BUTTERFLY (REFER TO <br />SPECIFICATIONS) <br />GLOBE VALVE <br />dd SOLENOID VALVE <br />A CHECKVALVE <br />151 BALANCING VALVE <br />PRESSURE REDUCING VALVE <br />REDUCED PRESSURE <br />BACKFLOW ASSEMBLY <br />PRESSURE RELIEF VALVE <br />TEMPERATURE AND PRESSURE <br />SAFETY RELIEF VALVE <br />�n SAFETY RELIEF VALVE <br />PIPING SPECIALTIES <br />-���- UNION <br />I FLANGE <br />FLEX CONNECTOR <br />THERMAL/SEISMIC FLEXIBLE <br />LOOP <br />THERMAL EXPANSION JOINT <br />STRAINER <br />STRAINER WITH BLOW OFF <br />VALVE <br />PIPE ANCHOR <br />ALIGNMENT GUIDE <br />TEMPERATURE/PRESSURE <br />TEST PORT <br />THERMOMETER <br />PRESSURE GAGE <br />PUMPS <br />Q CENTRIFUGAL PUMP <br />kBN INLINE PUMP <br />CIRCULATING PUMP <br />J BASE MOUNTED PUMP <br />DOMESTIC WATER PIPING SYSTEM <br />- DOMESTIC COLD WATER <br />DOMESTIC HOT WATER <br />DOMESTIC HOT WATER <br />CIRCULATION <br />DOMESTIC HOT WATER (TEMP. <br />X)(X") <br />STEAM PIPING SYSTEM <br />PR <br />HIPS <br />HPC <br />MPS <br />MPC <br />LPS <br />LPC <br />CONDENSATE PUMP RETURN <br />HIGH PRESSURE STEAM <br />(ABOVE 75 PSIG) <br />HIGH PRESSURE STEAM <br />CONDENSATE RETURN <br />MEDIUM PRESSURE STEAM <br />(15-75 PSIG) <br />MEDIUM PRESSURE STEAM <br />CONDENSATE RETURN <br />LOW PRESSURE STEAM <br />(0-15 PSIG) <br />LOW PRESSURE STEAM <br />CONDENSATE RETURN <br />STEAM TRAP <br />F&T = FLOAT AND THERMOSTATIC <br />IB = INVERTED BUCKET <br />-THERMODYNAMIC <br />COMPRESSED AIR PIPING SYSTEM <br />A COMPRESSED AIR <br />! COMPRESSED AIR DROP <br />Q COMPRESSED AIR PRESSURE <br />REGULATOR <br />FIRE PROTECTION SYSTEM <br />F <br />Fu <br />FD <br />-0 <br />0 <br />--DGF}AD� <br />FIRE SPRINKLER <br />FIRE MAIN <br />DRY SPRINKLER <br />RECESSED SPRINKLER HEAD <br />SEMI -RECESSED SPRINKLER <br />HEAD <br />UPRIGHT SPRINKLER HEAD <br />DOUBLE DETECTOR CHECK <br />VALVE/DOUBLE CHECK VALVE <br />ASSEMBLY <br />HYDRONIC PIPING SYSTEM <br />CONDENSATE DRAIN <br />HEATING WATER SUPPLY <br />HEATING WATER RETURN <br />AUTOMATIC AIR VENT/MANUAL <br />AIR VENT <br />BALANCING/MEASURING <br />VALVE <br />AUTOMATIC FLOW CONTROL <br />VALVE <br />ABBREVIATIONS <br />PJ <br />DIAMETER, PHASE <br />F <br />FAHRENHEIT, FIRE MAIN PIPING <br />NA <br />NOT APPLICABLE <br />FCO <br />FLOOR CLEANOUT <br />INC <br />NORMALLY CLOSED, NOISE CRITERIA <br />A <br />AIR, AMPS <br />FCU <br />FAN COIL UNIT <br />NIC <br />NOT IN CONTRACT <br />AAV <br />AUTOMATIC AIR VENT <br />FD <br />FIRE DAMPER, FLOOR DRAIN, DRY SPRINKLER <br />NO <br />NORMALLY OPEN, NITROUS OXIDE <br />ABV <br />ABOVE <br />ROUTING <br />NO. <br />NUMBER <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />NTS <br />NOT TO SCALE <br />AF <br />AIRFOIL <br />FF <br />FOULING FACTOR, FLAT FILTER <br />AFF <br />ABOVE FINISHED FLOOR <br />FFD <br />FUNNEL FLOOR DRAIN <br />OC <br />ON CENTER <br />AFUE <br />ANNUAL FUEL UTILIZATION EFFICIENCY <br />FLA <br />FULL LOAD AMPS <br />OD <br />OUTSIDE DIMENSION OR DIAMETER <br />AG <br />ABOVE GROUND <br />FLEX <br />FLEXIBLE <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />FLR <br />FLOOR <br />P <br />PUMP, PRESSURE, PLUMBING FIXTURE <br />AMB <br />AMBIENT <br />FLTR <br />FILTER <br />PD <br />PRESSURE DROP, PUMPED DRAIN <br />AP <br />ACCESS PANEL <br />FMS <br />FLOW MEASUREMENT STATION (HVAC, PLUMBING) <br />PH <br />PHASE <br />APD <br />AIR PRESSURE DROP <br />FOR <br />FUEL OIL RETURN PIPING <br />PIV <br />POST INDICATOR VALVE <br />ARCH <br />ARCHITECT <br />FOS <br />FUEL OIL SUPPLY PIPING <br />POC <br />POINT OF CONNECTION <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION <br />FOT <br />FUEL OIL TANK <br />PR <br />CONDENSATE PUMP RETURN <br />ASHRAE <br />AND AIR-CONDITIONING ENGINEERS, INC. <br />FP <br />FIRE PUMP, FLOATING POINT CONTROL <br />PRV <br />PRESSURE REDUCING VALVE <br />ASSY <br />ASSEMBLY <br />FPM <br />FEET PER MINUTE <br />PSIG <br />POUNDS PER SQUARE INCH GAGE <br />ATM <br />ATMOSPHERE <br />FPS <br />FEET PER SECOND <br />FS <br />FLOOR SINK <br />QTY <br />QUANTITY <br />B <br />BOILER <br />F/S <br />FIREISMOKE DAMPER <br />BF <br />BELOW FLOOR <br />FT <br />FEET, FIN TUBE <br />REF <br />REFERENCE, RETURN/EXHAUST FAN <br />BHP <br />BRAKE HORSE POWER <br />FTD <br />FOOTING DRAIN <br />RI&C <br />ROUGH IN AND CONNECT <br />BLW <br />BELOW <br />FTG <br />FOOTING DRAIN <br />RLA <br />RATED LOAD AMPS <br />BOP <br />BOTTOM OF PIPE <br />FV <br />FACE VELOCITY <br />RO <br />REVERSE OSMOSIS <br />BOT <br />BOTTOM <br />RPBA <br />REDUCED PRESSURE BACKFLOW ASSEMBLY <br />BTUH <br />BRITISH THERMAL UNIT PER HOUR <br />G <br />GAS <br />RPBP <br />REDUCED PRESSURE BACKFLOW PREVENTER <br />BV <br />BALL VALVE <br />GA <br />GAGE <br />RPM <br />REVOLUTIONS PER MINUTE <br />GAL <br />GALLONS <br />RV <br />SAFETY RELIEF VALVE <br />C <br />CONDENSATE PIPING <br />GALV <br />GALVANIZED <br />CA <br />AIR COMPRESSOR <br />GC <br />GAS COCK, GENERAL CONTRACTOR <br />CAP <br />CAPACITY <br />GFU <br />GAS FIRED UNIT <br />S <br />SENSOR <br />CBV <br />CIRCUIT SETTING BALANCING VALVE <br />GPF <br />GALLONS PER FLUSH <br />SCH <br />SCHEDULE <br />CD <br />CEILING DIFFUSER, CONDENSATE DRAIN <br />GPH <br />GALLONS PER HOUR <br />SENS <br />SENSIBLE <br />CFM <br />CUBIC FEET PER MINUTE <br />GPM <br />GALLONS PER MINUTE <br />SF <br />SUPPLY FAN, SQUARE FOOT <br />CKV <br />CHECK VALVE <br />GPRV <br />GAS PRESSURE REGULATING VALVE <br />SHC <br />STEAM HEATING COIL <br />CLG <br />CEILING, COOLING <br />GV <br />GATE VALVE, GLOBE VALVE <br />SIM <br />SIMILAR <br />CO <br />CLEANOUT, CO SENSOR <br />GW <br />GREASE WASTE PIPING <br />SOV <br />SHUTOFF VALVE <br />CO2 <br />CO2 SENSOR <br />GWB <br />GYPSUM WALLBOARD <br />SP <br />STATIC PRESSURE <br />COMB <br />COMBUSTION, COMBINATION <br />SPS <br />STATIC PRESSURE STATION <br />COND <br />CONDENSER, CONDENSATE <br />H <br />HUMIDISTAT, HEIGHT <br />SS <br />STAINLESS STEEL, SANITARY SEWER <br />CONN <br />CONNECTOR <br />HORIZ <br />HORIZONTAL <br />STM <br />STEAM <br />CONT <br />CONTINUE, CONTROL <br />HP <br />HORSEPOWER, HEAT PUMP <br />S.TK <br />STORAGETANK <br />COP <br />COEFFICIENT OF PERFORMANCE <br />HPC <br />HIGH PRESSURE CONDENSATE RETURN <br />COTG <br />CLEANOUT TO GRADE <br />HPS <br />HIGH PRESSURE STEAM <br />TD <br />TRENCH DRAIN, TEMPERATURE DIFFERENCE <br />CR <br />CONDENSATE RECEIVER, CONDENSER WATER <br />HRU <br />HEAT RECOVERY UNIT <br />TDH <br />TOTAL DYNAMIC HEAD <br />RETURN <br />HW <br />HOT WATER PIPING <br />TEMP <br />TEMPERATURE <br />CS <br />CONDENSER WATER SUPPLY <br />HWC <br />HOT WATER CIRCULATING PIPING <br />TOP <br />TOP OF PIPE <br />C. TK <br />COMPRESSION TANK <br />HWR <br />HOT WATER RETURN <br />TOS <br />TOP OF STEEL <br />ICU <br />CONDENSING UNIT, CUBIC <br />HWS <br />HOT WATER SUPPLY <br />T <br />TOPP FOOTING <br />CV <br />FLOW COEFFICIENT <br />HX <br />HEAT EXCHANGER <br />TRAP <br />STEAMM TRAP <br />CV <br />CONSTANT VOLUME <br />HZ <br />HERTZ <br />CW <br />COLD WATER PIPING <br />TSP <br />TOTAL STATIC PRESSURE <br />CWR <br />CONDENSING WATER RETURN <br />ID <br />INDIRECT DRAIN <br />T'STAT <br />TYP <br />THERMOSTAT <br />TYPICAL <br />CWS <br />CONDENSING WATER SUPPLY <br />IE <br />INVERT ELEVATION <br />IN. <br />INCH <br />UG <br />UNDERGROUND <br />D <br />DRAIN <br />IN. WIG <br />INCHES WATER COLUMN <br />UNO <br />UNLESS NOTED OTHERWISE <br />DB <br />DRY BULB (TEMPERATURE) <br />IRR <br />IRRIGATION PIPING <br />dB <br />DECIBEL <br />IW <br />INDIRECT WASTE PIPING <br />V <br />VENT PIPING, VOLT <br />DCVA <br />DOUBLE CHECK VALVE ASSEMBLY <br />VA <br />VALVE <br />DDCV <br />DOUBLE DETECTOR CHECK VALVE <br />kW <br />KILOWATT <br />DEG <br />DEGREE <br />VAV <br />VARIABLE AIR VOLUME <br />DFU <br />DRAINAGE FIXTURE UNIT <br />L <br />LENGTH <br />VCD <br />VOLUME CONTROL DEVICE <br />DI <br />DUCTILE IRON <br />LAT <br />LEAVING AIR TEMPERATURE <br />VD <br />VEL <br />VOLUME DAMPER <br />VELOCITY <br />CIA <br />DIAMETER <br />LB <br />LINEAR BAR <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />DIM <br />DIMENSION <br />LBS <br />POUND <br />VOLT <br />VOLTAGE <br />DISC <br />LOCATION OF STARTER, DISCONNECT AND <br />LPS <br />LOW PRESSURE STEAM <br />VTR <br />VENT THRU ROOF <br />CONTROLS <br />URA <br />LOCKED ROTOR AMPS <br />DISCH <br />DISCHARGE <br />LR <br />LINEAR RETURN <br />DIN <br />DOWN <br />W <br />WASTE, WATT, WIDE, WATER <br />DPV <br />DIFFERENTIAL PRESSURE VALVE <br />W/ <br />WITH <br />DWGS <br />DRAWINGS <br />MAX <br />MANUAL AIR VENT <br />WB <br />WET BULB (TEMPERATURE) <br />DV <br />DRAIN VALVE <br />MAX <br />MAXIMUM <br />VIC <br />WATER CLOSET, WATER COLUMN <br />DWB <br />DOMESTIC WATER BOOSTER <br />MBH <br />THOUSAND BTU PER HOUR <br />WG <br />WATER GAGE <br />MC <br />MECHANICAL CONTRACTOR <br />WH <br />WATER HEATER, WALL HYDRANT <br />(E) <br />EXISTING <br />MCA <br />MINIMUM CIRCUIT AMPACITY <br />WHA <br />WATER HAMMER ARRESTOR <br />EA <br />EXHAUST AIR <br />MECH <br />MECHANICAL <br />WM <br />WATER METER <br />EAT <br />ENTERING AIR TEMPERATURE <br />MERV <br />MINIMUM EFFICIENCY REPORTING VALUE <br />WSEC <br />WASHINGTON STATE ENERGY CODE <br />EER <br />ENERGY EFFICIENCY RATIO <br />MIN <br />MINIMUM <br />WSFU <br />WATER SUPPLY FIXTURE UNIT <br />MOCP <br />MAXIMUM OVERCURRENT PROTECTION <br />WT <br />WEIGHT <br />EFF <br />EFFICIENCY <br />MOD <br />MOTOR OPERATED DAMPER <br />EL <br />ELEVATION <br />MPC <br />MEDIUM PRESSURE CONDENSATE RETURN <br />ELEC <br />ELECTRIC <br />MPG <br />MEDIUM PRESSURE GAS <br />EMCS <br />ENERGY MANAGEMENT AND CONTROL SYSTEM <br />MPS <br />MEDIUM PRESSURE STEAM <br />EQUIV <br />EQUIVALENT <br />ESP <br />EXTERNAL STATIC PRESSURE <br />ET <br />EXPANSION TANK <br />EVAP EVAPORATOR, EVAPORATIVE <br />EWC ELECTRIC WATER COOLER <br />EWT ENTERING WATER TEMP <br />EXT EXTERIOR, EXTERNAL <br />GENERAL NOTES - MECHANICAL NON-STRUCTURAL MECHANICAL COMPONENT NOTES <br />1. COORDINATE MECHANICAL WORK WITH THAT OF OTHER <br />TRADES (ELECTRICAL, ARCHITECTURAL, STRUCTURAL, <br />CIVIL, AND LANDSCAPE). REFER TO ELECTRICAL, <br />ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE <br />DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL <br />OCCUR PRIOR TO FABRICATION, PURCHASE, AND/OR <br />INSTALLATION OF ALL WORK. <br />2. COORDINATE PLUMBING, HVAC, AND FIRE PROTECTION <br />SYSTEMS ROUTING PRIOR TO INSTALLATION. DURING <br />LAYOUT COORDINATION, DUCTWORK TAKES PRECEDENCE <br />OVER PLUMBING, INCLUDING FIRE PROTECTION SYSTEMS. <br />3. [REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS <br />FOR LOCATIONS OF EXPANSION/SEISMIC JOINTS. PROVIDE <br />EXPANSION/SEISMIC JOINTS FOR PIPING AND DUCTWORK <br />CROSSING EXPANSION/SEISMIC JOINTS.] [DELETE NOTE IF <br />THERE ARE NO EXPANSION/SEISMIC JOINTS ON PROJECT - <br />COORDINATE WITH THE STRUCTURAL ENGINEER. SHOW <br />EXPANSION/SEISMIC JOINTS FOR PIPING AND DUCTWORK <br />ON DRAWINGS] <br />4. UNLESS OTHERWISE SPECIFIED, THE GENERAL <br />CONTRACTOR (GC) SHALL BE RESPONSIBLE FOR PAINTING, <br />CUTTING, AND PATCHING OF EXISTING FLOORS, WALLS, <br />AND PARTITIONS IN THE EXISTING BUILDING. <br />5. REFER TO STRUCTURAL DRAWINGS FOR ALLOWABLE <br />METHODS/LOADS FOR HANGING PIPING/DUCTS FROM <br />STRUCTURAL MEMBERS. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE <br />KEEPING OF HIS OWN PROPERTY ON THE JOB SITE. <br />OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION <br />OF PROPERTIES AGAINST FIRE, THEFT, AND <br />ENVIRONMENTAL CONDITIONS. <br />MECHANICAL EQUIPMENT INSTALLATION NOTES <br />1. ACCESS CLEARANCES FOR MAINTENANCE AND <br />REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF <br />EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN <br />BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK <br />AND WORK OF OTHER TRADES TO PROVIDE ACCESS <br />CLEARANCES FOR SERVICE AND MAINTENANCE. <br />PIPING NOTES <br />1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR <br />FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, <br />TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO <br />ALLOW DISASSEMBLY FOR MAINTENANCE. <br />2. REFRIGERANT PIPING: PROVIDE SIZING AND INSTALLATION <br />IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS AND IN SUCH A WAY AS TO BE <br />INCONSPICUOUS AND FREE FROM ANY POSSIBLE <br />CONDENSATION. PIPE SIZES NOTED ARE FOR REFERENCE <br />AND SHALL BE INSTALLED PER MANUFACTURERS <br />RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE <br />CONTROL WIRING BETWEEN EQUIPMENT FOR AN <br />OPERATIONAL SYSTEM. <br />3. PRESSUREFFEMPERATURE TEST PORTS: PROVIDE AT <br />SUPPLY AND RETURN PIPING CONNECTIONS TO <br />EQUIPMENT. <br />4. PROVIDE AN INSULATED COPPER TRACER WIRE OR OTHER <br />APPROVED CONDUCTOR ADJACENT TO UNDERGROUND <br />NONMETALLIC (PLASTIC) PIPING. ACCESS SHALL BE <br />PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE <br />SHALL TERMINATE ABOVE GROUND AT EACH END OF THE <br />PIPING. THE TRACER WIRE SHALL NOT BE LESS THAN NO. <br />18 AWG AND THE INSULATION TYPE SHALL BE SUITABLE <br />FOR BURIAL. <br />5. PROVIDE 12" LONG, 1/2' WIDE FLUORESCENT ORANGE TAPE <br />AT CONCEALED VALVE LOCATIONS. <br />PLUMBING NOTES <br />1. WATER HAMMER ARRESTORS: PROVIDE AT THE END OF <br />HOT AND COLD WATER LINES SERVING TWO OR MORE <br />FIXTURES. SIZE IN ACCORDANCE WITH PLUMBING AND <br />DRAINAGE INSTITUTE (PDI) REQUIREMENTS. <br />2. REDUCED PRESSURE BACKFLOW PREVENTERS (RPBP): <br />PROVIDE INDIRECT DRAIN PIPING FROM RPBP TO NEAREST <br />DRAIN. INSTALL FUNNEL AT RPBP IF REQUIRED. <br />3. ACCESS PANELS: PROVIDE IN NON ACCESSIBLE CEILINGS <br />AND WALLS FOR VALVES, WATER HAMMER ARRESTERS, <br />CLEANOUTS, AND OTHER ITEMS THAT REQUIRE ACCESS <br />TO PROPERLY MAINTAIN OR SERVICE THE BUILDING. <br />REFER TO SPECIFICATIONS. <br />4. CLEANOUTS: PROVIDE AT THE BASE OF SANITARY <br />DRAINAGE, PROCESS WASTE, AND RAINLEADER <br />CONDUCTORS. <br />5. WATER SUPPLY DISINFECTION TEST, REFER TO SCHEDULE <br />WON PUBLIC HEALTH SEATTLE KING COUNTY'S (PHSKC) <br />WEBSITE FOR DISINFECTION OF POTABLE WATER SYSTEM <br />IN ACCORDANCE WITH SEATTLE PLUMBING CODE (SPC) <br />SECTION 609.9. NOTE: PLUMBING PERMITS WILL NOT BE <br />APPROVED FOR FINAL INSPECTION UNTIL DISINFECTION <br />TEST MEETS DRINKING WATER QUALITY. <br />1. THE COMPONENT IMPORTANCE FACTOR (Ip) FOR ALL <br />NON-STRUCTURAL COMPONENTS SHALL BE: <br />Ip = 1.0 <br />2. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE <br />2018 INTERNATIONAL BUILDING CODE AND FROM THE <br />AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) <br />STANDARD 7. THE CONTRACTOR SHALL REFER TO THE <br />ABOVE FOR ADDITIONAL INFORMATION, EXCEPTIONS, AND <br />FURTHER DESCRIPTIONS. THE CONTRACTOR SHALL <br />ADHERE TO REQUIREMENTS AND AS SUCH, SHALL BE <br />INCLUDED WITHIN BID. ALSO REFER TO SPECIFICATION <br />SECTION [15210] [2305501. <br />3. 2018 IBC, 1613.1, SCOPE: ARCHITECTURAL, MECHANICAL, <br />ELECTRICAL, AND NON-STRUCTURAL COMPONENTS THAT <br />ARE PERMANENTLY ATTACHED TO STRUCTURES AND <br />THEIR SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED <br />AND CONSTRUCTED TO RESIST THE EFFECTS OF <br />EARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7, <br />EXCLUDING CHAPTER 14 AND APPENDIX 11A. <br />4. 2018 IBC, 1704.4, CONTRACTOR RESPONSIBILITY: THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />CONSTRUCTION OF A SEISMIC -FORCE -RESISTING SYSTEM, <br />DESIGNATED SEISMIC SYSTEM, OR SEISMIC -RESISTING <br />COMPONENT LISTED IN THE STATEMENT OF SPECIAL <br />INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT <br />OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE <br />OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE <br />SYSTEM OR COMPONENT. THE CONTRACTOR'S <br />STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE <br />FOLLOWING: <br />A. ACKNOWLEDGEMENT OF AWARENESS OF THE <br />SPECIAL REQUIREMENTS CONTAINED IN THE <br />STATEMENT OF SPECIAL INSPECTIONS; <br />B. ACKNOWLEDGEMENT THAT CONTROL WILL BE <br />EXERCISED TO OBTAIN CONFORMANCE WITH THE <br />CONSTRUCTION DOCUMENTS APPROVED BY THE <br />BUILDING OFFICIAL; <br />C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE <br />CONTRACTOR'S ORGANIZATION, THE METHOD AND <br />FREQUENCY OF REPORTING AND THE DISTRIBUTION <br />OF THE REPORTS; <br />D. IDENTIFICATION AND QUALIFICATIONS OF THE <br />PERSON(S) EXERCISING SUCH CONTROL AND THEIR <br />POSITION(S) IN THE ORGANIZATION. <br />4. DIVISION 21, 22,23 RESPONSIBILITIES: <br />A. HANGERS AND SEISMIC BRACING FOR MECHANICAL <br />SYSTEMS SHALL BE DESIGNED AND SPECIFIED BY <br />DIVISION 21, 22, 23. DIVISION 21, 22,23 SHALL REFER <br />TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF <br />EQUIPMENT AND HUNG MECHANICAL SYSTEMS AS <br />STRUCTURAL DRAWINGS DO NOT SHOW THE <br />LOCATIONS OF MECHANICAL EQUIPMENT, DUCTWORK, <br />PIPING, AND OTHER COMPONENTS. <br />B. DIVISION 21, 22, 23 SHALL COORDINATE THE SUPPORT <br />SYSTEMS AND DESIGN LOADS FOR HUNG PIPING AND <br />OTHER MECHANICAL SYSTEMS (INCLUDING COMBINED <br />MULTIPLE PIPE RUNS) WITH THE GENERAL <br />CONTRACTOR AND THE STEEL AND WOOD JOIST <br />MANUFACTURERS IN ADDITION TO OTHER TRADES <br />THAT MAY BE IMPACTED. <br />ENERGY CODE NOTES <br />1. MOTORS: COMPLY WITH MINIMUM FULL LOAD <br />EFFICIENCIES LISTED IN ENERGY CODE ENFORCED BY AHJ. <br />2. PIPING AND DUCT INSULATION: COMPLY WITH <br />THICKNESSES AND TYPES LISTED IN ENERGY CODE <br />ENFORCED BY AHJ UNLESS MORE STRINGENT <br />REQUIREMENTS ARE SPECIFIED. [PROVIDE SCHEDULES <br />ON DRAWINGS IF REQUIRED BY AHJ] <br />3. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND <br />LONGITUDINAL SEAMS PER ENERGY CODE ENFORCED BY <br />AHJ UNLESS MORE STRINGENT REQUIREMENTS ARE <br />SPECIFIED. <br />4. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER <br />PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. <br />5. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE <br />BUILDING OWNER PER ENERGY CODE ENFORCED BY THE <br />LOCAL AHJ. <br />6. SYSTEM BALANCING: BALANCE HVAC SYSTEMS PER <br />ENERGY CODE ENFORCED BY THE LOCAL AHJ AND SUBMIT <br />A WRITTEN REPORT TO THE BUILDING OWNER. REFER TO <br />SPECIFICATIONS FOR ADDITIONAL TESTING, ADJUSTING, <br />AND BALANCING (TAB) REQUIREMENTS. <br />7. MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION <br />REQUIREMENTS: TEST SYSTEMS TO ENSURE THAT <br />BUILDING SYSTEMS HAVE BEEN DESIGNED, INSTALLED, <br />AND FUNCTION PROPERLY, EFFICIENTLY, AND CAN BE <br />MAINTAINED IN ACCORDANCE WITH THE CONTRACT <br />DOCUMENTS IN ORDER TO SATISFY THE BUILDING <br />OWNER'S DESIGN INTENT AND OPERATIONAL <br />REQUIREMENTS PER ENERGY CODE ENFORCED BY THE <br />LOCAL AHJ. REFER TO SPECIFICATIONS FOR ADDITIONAL <br />COMMISSIONING REQUIREMENTS <br />8. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN <br />DESIGNED TO COMPLY WITH ENERGY CODE ENFORCED BY <br />THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR <br />CORRECT INSTALLATION OF ENERGY CONSERVATION <br />MEASURES. <br />DRAWING INDEX <br />MO.1 MECHANICAL LEGEND, ABBREVIATIONS, & GENERAL <br />NOTES <br />MD1.01 MECHANICAL DEMOLITION SITE PLAN <br />NOT ALL SYMBOLS MAY <br />APPEAR ON THE DRAWINGS <br />MITHUN <br />SEATTLE I Pi., M, 1201 Alaskan Way,#200 <br />S.M., WA 991011206.623.3344 <br />SAN FRANCISCO I860 M.Kk Street #300 <br />San F.md-, CA 941041415.956.008 <br />LOS ANGELES 15837 Adams Blvd <br />Culver City, CA 902321323.07.2150 <br />mltNun.com <br />H A R G I S <br />--vaxw <br />Nro <br />PROJECT <br />Monte Cristo Hall and <br />Annex Demolition <br />LOCATION <br />2000 Tower Street <br />Everett, WA 98201 <br />PREPARED FOR <br />Everett Community <br />College <br />HARGIS <br />BC <br />w ea <br />CC 1-1 <br />PRR -Brian <br />PRR NeNaaaa <br />BC <br />6577 <br />REGISTERED <br />RC ITECT <br />WALT HACHT <br />STATE OF WASHINGTON <br />MECHANICAL LEGEND, <br />ABBREVIATIONS, & <br />GENERAL NOTES <br />19099 <br />28 NOVEMBER 2022 <br />Mab.01 <br />PERMIT SET <br />C 2016 MITHUN, INC. <br />NnT FnR CUMSTRl1CTIUM <br />