Laserfiche WebLink
NOT LESS THMY;/W NOT MORE <br /> THAN Z DA TYP.R*VKAL(GONM <br /> r-SD KETL.RN "34'-38,Mk4VLM <br /> HEIGHT FKOM FIN PLOOK To TOP OF <br /> HFtNDKAL nPGAL) <br /> 4. Please add a general note or note on the floor plan that all egress window sill height is less than 44" <br /> above finish floor. IRC R310.2.3 <br /> 5. Hallway dimensions appears to be from drywall to drywall. Please confirm. If not,the hallway <br /> clearance should be 36"from drywall to drywall per IRC R311.6. <br /> 6. Please provide roof ventilation calculation per IRC R806.1 for the "addition" space. <br /> 7. Kitchen hood ventilation rate should be clearly noted with confirmed CFM instead of using 100 CFM <br /> min.. If more than 400 cfm, please provide makeup air per IRC M1503.6. <br /> This review has been performed for general compliance with the building codes as adopted and amended by <br /> the state of Washington and the city of Everett. Corrections and comments made during the review process <br /> do not relieve the project from compliance with code and permit requirements.The designers-of-record are <br /> responsible for a complete design in accordance with the laws of the state of Washington. <br /> For a full list of applicable codes adopted by the City of Everett, please see the Construction Codes (PDF). <br /> If you have any questions or require additional clarification, please contact us. <br /> Sincerely, <br /> — Yin Lu, R.A. <br /> Building Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/Th: 8:30 a.m.—12 p.m & 1 p.m.—3 p.m. <br /> everettwa.gov/permits I onlinepermits.everettwa.gov I Facebook I Twitter <br /> 3200 Cedar Street ©425.257.8810 O permitservices@everettwa.gov <br /> Everett, WA 98201 everettwa.gov/permits <br /> Page 2 of 2 <br />