r CAUTION: F THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT <br /> ABBREVIATIONS GENERAL PROJECT NOTES 3 000 <br /> > N O 1 <br /> a v m o <br /> & And D. nside Diameter(Dim.) GENERAL NOTES: JOB SITE NOTES: ^3 <br /> L Angle INSUL. InsulationCOMMON AREA z <br /> ® At INT. Interior 1. ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL, INDUSTRY 1. WHERE EXISTING TENANTS/BUSINESSES ARE ADJACENT TO THE JOB SITE/TENANT, v m <br /> fp Centerline AND PROJECT-SPECIFIC REQUIREMENTS AND STANDARDS INCLUDING WITHOUT THE CONTRACTOR SHALL MINIMIZE CONSTRUCTION NOISE- EXTREMELY NOISY <br /> Jan. Janitor LIMITATION OF THE FOLLOWING: CONSTRUCTION SHALL OCCUR AT NON-TYPICAL BUSINESS HOURS. CONTRACTOR <br /> Diameter or Round JT. Joint SHOULD NOTFY BUILDING REPRESENTATIVE OF SPECIAL CIRCUMSTANCES IN t <br /> q Pound or Number KIT. Kitchen ADVANCE PRIOR TO WORK. <br /> (E) Existing K.O. Knock Out A. ALL APPLICABLE BUILDING CODES <br /> B. ALL APPLICABLE SPECIALTY CODES INCLUDING THE MOST CURRENT ISSUES AND 2. THE CONTRACTOR AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AND w r w <br /> ACOUS. Acoustical LAB. Laboratory z .y <br /> SUPPLEMENTS SURROUNDING AREA FREE FROM DUST AND DEBRIS. THE WORK SHALL BE IN r o <br /> ACT. Acoustical Tile LAM. Laminate m <br /> AD. Area Drain LAV. Lavatory C. THE PROJECT MANUAL AND ASSOCIATED SPECIFICATIONS CONFORMANCE WITH THE AIR AND WATER POLLUTION CONTROL STANDARDS AND o <br /> ADJ. Adjustable LKR. Locker D. THE MANUFACTURER'S REQUIREMENTS OR RECOMMENDATIONS REGULATIONS OF THE STATE DEPARTMENT OF HEALTH. <br /> AFF. Above Finish Floor LT. Light E. ALL APPLICABLE LANDLORD BUILDING STANDARDS UPGRADES o <br /> AGGR. Aggregate 3. CONSTRUCTION DEBRIS AND WASTES SHALL BE DEPOSITED AT AN APPROPRIATE a <br /> AL. Aluminum MAX. Maximum SITE. THE CONTRACTOR SHALL INFORM THE BUILDING REPRESENTATIVE OF THE <br /> 2. IN USING THESE PLANS FOR BIDDING OR CONSTRUCTION PURPOSES,ALL LOCATION OF DISPOSAL SITES. <br /> APPROX. Approximate M.C. Medicine o w <br /> CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN <br /> ARCH. Architectural MECH. Mechanical ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL CLEANING OF THE JOB _ w <br /> ASB. Asbestos MEMB. Membrane a u % <br /> ASPH. Asphalt MET. Metal THEIR PORTION OF THE WORK,EVEN REQUIREMENTS LOCATED IN SECTIONS AFTER ITS COMPLETION. WHERE APPLICABLE,CLEANING SHALL INCLUDE, BUT EVERETT MALLOFFICE PARK BLD . I I 1 MFR. Manufacturer DESIGNATED AS APPLICABLE TO OTHER TRADES OR IN DOCUMENTS PROVIDED BY NOT BE LIMITED T0, THE EXTERIOR AND THE INTERIOR OF THE BUILDING, THE <br /> BE. Board MH. Manhole OTHER MEMBERS OF THE PROJECT DESIGN TEAM. UNLESS EXPRESSLY PROVIDED PATH OF TRAVEL TO THE JOB SITE, PARKING LOTS,ELEVATORS, LOBBIES, AND rJ < i s <br /> BITUM. Bituminous MIN. Minimum OTHERWISE,THE INTENT IS TO INCLUDE ALL LABOR,MATERIALS,PRODUCTS AND CORRIDOR CARPETS. W i i <br /> BLDG. Building MIR. Mirror SERVICES NECESSARY OR APPROPRIATE FOR THE COMPLETED PROJECT AS o c <br /> ELK. Block MISC. Miscellaneous CALLED FOR OR REASONABLY IMPLIED FROM THE PLANS AND SPECIFICATIONS 5. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, WHERE REQUIRED a 9 <br /> BM. Blocking M.O. Masonry Opening PROVIDED BY THE AFFECTED <br /> C DESIGN TEAM. IN CASE OF CONFLICTS OR PER STATE AND LOCAL CODES. 1000 SE EVERETT MALL WAY m m <br /> BM. Beam MTD. Mounted OMISSIONS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN o <br /> B.O.C. Bottom of Concrete MILL. Mullion DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER,OR 6. IF TRENCHES OR EXCAVATIONS 5'-0"OR MORE IN DEPTH ARE REQUIRED,OBTAIN w <br /> B.O.M. Bottom of Mullion OTHERWISE TO APPLY THE MORE STRINGENT OR COSTLY STANDARD. ISSUANCE OF A BUILDING OR GRADING PERMIT. ? F <br /> B.O.P. Bottom of Panel N. North o U. i <br /> B.O.R. Bottom of Reveal N.I.C. Not In Contract 3. IN INTERPRETING THESE PLANS,THE FOLLOWING GENERAL RULES APPLY: 7. NO HAZARDOUS MATERIALS SHALL BE USED R STORED WITHIN THE BUILDING <br /> BOY. Bottom N0. Number WHICH DOES NOT COMPLY WITH THE LOCAL FIRE AUTHORITY AND STATE& i x z w <br /> B/S. Building Standard NOM. Nominal COUNTY REQUIREMENTS. a i <br /> N.T.S. Not To Scale A. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS m <br /> CAB. Cabinet B. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES 8. CONTRACTOR SHALL BE RESPONSIBLE FOR BLOCKING OFF SUPPLY AND RETURN (For Common Area Improvement Permit Only) <br /> C.B. Catch Basin O.A. Overall AND TYPICAL DETAILS AIR GRILLES,DIFFUSERS&DUCTS TO KEEP DUST FROM ENTERING INTO BUILDING <br /> CEM. Cement OBS. Obscure C. WORK NOT PARTICULARLY SHOWN OR SPECIFIED SHALL BE THE SAME AS AIR DISTRIBUTION SYSTEMS. <br /> O.C. On Center m <br /> CER. Ceramic SIMILAR PARTS THAT ARE SHOWN AND SPECIFIED <br /> O.D. Outside Diameter(Dim.) 9. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SHEET INDEX <br /> CIF CONT. Furnished/CONY. Installed D. WORK SHOWN AS"NIL'"IS FOR REFERENCE ONLY AND THE RESPONSIBILITY OF PROJECT DATA <br /> C 101. OFCI. Owner Furnished/CONY. Installe THE CONTRACTOR ONLY TO THE EXTENT THAT THIS WORK MAY REQUIRE SOME SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. <br /> C.I. CONY. Furnished/Oner Installed OFOI. Owner Furnished/Owner Installe REASONABLE PROTECTION OR COORDINATION EFFORTS. <br /> Cast Iron OFF. Office 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE <br /> C.G. Corner Guard OPNG. a <br /> CLG. Ceiling OPP Opening BUILDING AND SITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS w <br /> CLKG. Caulking Opposite COMPLETED. BUILDING DEPARTMENT: CITY OF EVERETT SHEET ISSUED ON DATE INDICATED,WITH MODIFICATIONS <br /> CLO. Closet FROST. Pre-cast T THESE PLANS AND SPECIFICATIONS ARE INTENDED TO REPRESENT ONLY THE SHEET ISSUED ON DATE INDICATED,NO MODIFICATIONS O N <br /> CLR. Clear PL. Plate FINISHED CONSTRUCTION. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL BUILDING CODES: } <br /> C.O. Cased Opening P.LAM. Plastic Laminate CONSTRUCTION AND DEMOLITION MEANS, METHODS, TECHNIQUES,SEQUENCES AND DRAWING NOTES: 2018 INTERNATIONAL BUILDING CODE a <br /> COL. Column PLAS. Plaster PROCEDURES INCLUDING ANY AND ALL SAFETY PRECAUTIONS AND PROGRAMS, 2018 INTERNATIONAL EXISTING BUILDING CODE <br /> C.O.M. Center of Mullion PLYWD. Plywood AND SHALL INDEMNIFY TO THE FULLEST EXTENT ALLOWED BY LAW THE OWNER 1. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS 2018 INTERNATIONAL MECHANICAL CODE <br /> CONC. Concrete PR. Pair AND THE PROJECT DESIGN TEAM FROM AND AGAINST ANY AND ALL RELATED SHALL BE TO FACE OF CURB, FACE OF CONCRETE OR MASONRY,FACE OF FINISH 2O18 INTERNATIONAL FIRE CODE N <br /> CONN. Connection PT. Point CLAIMS AND LIABILITY. OR CENTERLINE OF GRIDS, 2018 WASHINGTON STATE ENERGY CODE ca <br /> CONST. 2018 UNIFORM PLUMBING CODE <br /> Can P.T.D Paper Towel Dispenser GENERAL <br /> CONY. Continuous 5. THESE PLANS AND SPECIFICATIONS ARE INTENDED TO SET FORTH THE 2. ALL VERTICAL DIMENSIONS SHOWN ARE FROM FLOOR SLAB, U.O.N. 2020 NFPA 70,NATIONAL ELECTRIC CODE <br /> P.T.D/R Combination Paper Towel 2018 WASHINGTON STATE-WIDE AMENDMENTS <br /> CONTR. Contractor REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF 10.1 TITLE SHEET <br /> P.T. Partition 2009 ICC A117.1 - ANSI <br /> C.O.R. Center of Reveal QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY 3. DIMENSIONS SHOWN IN FIGURES TAKE PRECEDENCE OVER DIMENSIONS SCALED <br /> P.T.R. Paper Towel Receptacle p <br /> CPT. Corridor P.J. Panel Joint APPROPRIATE REQUESTS FOR INFORMATION (L CO ERRORS AND OMISSIONS ARE FROM DRAWINGS. LARGE SCALE DRAWINGS AND DETAILS TAKE PRECEDENCE OVER OCCUPANCY CLASSIFICATION: PER IBC CHAPTER 3 SECTION 302 - B 10.2 GENERAL NOTES <br /> CPT. Carpet TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO SMALLER SCALE DRAWINGS. ( ) _ <br /> CTSK. CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING 10.3 ACCESSIBILITY DETAILS _ <br /> Countersunk Q.T. Quarry Tile <br /> CNTR. Counter THESE ERRORS AND OMISSIONS TO THE ATTENTION OF AN APPROPRIATE OWNER 4. THE TERM "ALIGN", AS USED IN THESE DOCUMENTS, SHALL MEAN TO FIRE PARTITION: PER IBC CHAPTER 7 - N/A INTERIOR <br /> CTR. Center R. Riser REPRESENTATIVE IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO ACCURATELY LOCATE FINISHES IN THE SAME PLANE. / <br /> C.W. Cold Water RAD. Radius SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY <br /> 10.4a FL 02 OCCUPANCY AND EGRESS PLAN <br /> R.D. Roof Drain CONSEQUENCES. 5. "TYPICAL"AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS <br /> D. Deep REF. Reference THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS THROUGHOUT, TYPE OF CONSTRUCTION: PER IBC CHAPTER 6(SECTION 602) - II-FR 10.4b FL 03 OCCUPANCY AND EGRESS PLAN i <br /> DBL. Double REFR. Refrigerator U.O.N. N <br /> DEPT. Department RGTR. Register 6. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY IE2a FLOOR 2 1 DEMOLITION FLOOR PLAN o <br /> D.F. Drinking Fountain REINS Reinforced EVENT ALL CONTRACTORS PROCEED AT THEIR OWN RISK IF THEY FAIL TO VERIFY SPRINKLERED: WON SPRINKLERED a <br /> DET. Detail REQ. Required AND FIELD MEASURE DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED 6. DETAILS ARE USUALLY KEYED AND NOTED"TYPICAL"ONLY ONCE,WHEN THEY N.2b FLOOR 2 DEMOLITION CEILING PLAN <br /> DIA. Diameter q FIRST OCCUR AND ARE REPRESENTATIVE OF ALL SIMILAR CONDITIONS N <br /> RESIL. Resilient PROCUREMENT,FABRICATION OR CONSTRUCTION. THROUGHOUT,U.O.N. 11.3a FLOOR 3 DEMOLITION FLOOR PLAN 4 <br /> DIAL. Diagonal RM. Room NUMBER OF STORIES: 4 <br /> DIFF. Diffuser z <br /> R.O. Rough Opening 7. COLUMN CENTERLINES(GRID LINES)ARE SHOWN FOR DIMENSIONING PURPOSES. 11.3b FLOOR 3 DEMOLITION CEILING PLAN <br /> DIM. Dimension RWD. Redwood 7. PLANS AR E TO BE CONSIDERED DIAGRAMMATIC IN NATURE AND INTENDED ONLY <br /> DISP. Dispenser R.W.L. Rain Water Leader TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO ASSESSOR'S PARCEL NO.: 28051800305401 Wle FLOOR 2 CEILING PLAN � Q <br /> DN. Down DEPICT SPECIFIC LOCATIONS.. 8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF o <br /> D.O. Door Opening S. South THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN I4.ib FLOOR 3 CEILING PLAN ¢ J <br /> DR. Door S.C. Solid Core 8. CONTRACTOR RFI's ARE INTENDED TO OBTAIN INFORMATION NOT AVAILABLE FROM THE SAME BUILDING. OFFICE(B) N <br /> DWR. Drawer S.C.D. Seat Cover Dispenser 15.2a FLOOR 2 FLOOR&FINISH PLAN m <br /> THE PLANS AND SPECIFICATIONS. RFI's WILL NOT BE PROCESSED THAT CAN BE PROJECT SCOPE: /� <br /> DS. Downspout SCHED. Schedule INTERIOR/EXTERIOR NOTES: THE SCOPE OF THIS PROJECT IS TO PROVIDE INTERIOR COMMON AREA BUILDING IMPROVEMENTS TO \� <br /> ANSWERED BY A REVIEW FROM <br /> THESE DOCUMENTS, THAT REQUEST DIMENSIONS 15.2b FLOOR 2 MILLWORK&WALL FINISHES PLAN o <br /> D.S.P. Dry Standpipe S.D. Soap Dispenser 2ND AND 3RD FLOORS OF EXISTING OFFICE B FOR USE AS THE SAME. NO CHANGE OF USE A <br /> THAT CAN BE OBTAINED FROM THE PLANS BY MATHEMATICAL CALCULATION THAT Y DWG Drawing SECT. Section ANTICIPATED. INTERIOR CONSTRUCTION TO INCLUDE DEMOLITION OF CEILING GRID, ACT TILES AND w <br /> ARE IN EFFECT A SUBSTITUTION SUBMITTAL,OR THAT SEEK DIRECTION 1. WHERE ELECTRICAL,MECHANICAL AND/OR PLUMBING ITEMS,SUCH AS LIGHTS, 15.3a FLOOR 3 MILLWORK&WALL FINISHES PLAN <br /> SH. Shelf LIGHT FIXTURES, WHERE NOTED, AND INTERIOR WALL&FLOOR FINISHES. NEW INTERIOR z <br /> E. East CONCERNING CONSTRUCTION MEANS AND METHODS OR SAFETY PRECAUTIONS. DUCTS, PIPING,DOWNSPOUTS,ETC. ARE TO PENETRATE ANY BUILDING FOOTINGS, <br /> SHR. Shower SLABS, FLOORS,STRUCTURAL FRAMING, WALL PARTITIONS, CEILINGS,ETC., IT IS CONSTRUCTION TO INCLUDE NEW GWB CEILING, NEW ACT TILE, NEW LIGHT FIXTURES AND NEW o <br /> EA. Each WHERE APPROPRIATE, RFI's SHOULD BE SPECIFIC AS TO WHICH PORTION OF THE 15.3h FLOOR 3 FLOOR FINISHES PLAN J <br /> SHY. Sheet REQUIRED THAT AN APPROPRIATELY SIZED OPENING OR CLEARANCE BE WALL AND FLOOR FINISHES. w <br /> E.J. Ex ansion Joint PLANS AND SPECIFICATIONS NEEDS CLARIFICATION,AND WHAT INFORMATION IS O <br /> P SIM. Similar REQUIRED. FURNISHED. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ITEMS Is.ta FLOOR 2 ENLARGED RESTROOM PLANS&ELEVATIONS REFERENCE FOR FLOOR 3 a ^ <br /> EL. Elevation S.N.D. Sanitary Napkin Disp. WITH THE CONSTRUCTION DOCUMENTS PRIOR TO THE INSTALLATION OF L.L Q Op <br /> ELEC. Electrical S.N.R. Sanitary Napkin Recept. STRUCTURAL,MECHANICAL, PLUMBING AND ELECTRICAL WORK, ANY CONFLICT OR 16.2 ELEVATIONS&MISCELLANEOUS DETAILS "' O <br /> ELEV. Elevator SPEC. Specification 9. NO DEVIATIONS OR OMISSIONS FROM THE REQUIREMENTS OF THE PLANS AND <br /> P DISCREPANCY WITHIN CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE C W N <br /> EMER. Emergency S S uare SPECIFICATIONS PROVIDED BY THE PROJECT'S DESIGN TEAM ARE ALLOWED 18.2 CEILING DETAILS&INTERIOR ELEVATIONS J LJ U00 <br /> Q. q ARCHITECT'S ATTENTION FOR CLARIFICATION. <br /> ENCL. Enclosure WITHOUT THE EXPRESSED AUTHORIZATION OF AN APPROPRIATE OWNER <br /> S.ST. Stainless Steel a <br /> E.P. Electrical Panelboard S.SK. Service Sink <br /> REPRESENTATIVE AND THE RESPONSIBLE CONTRACTOR WILL INDEMNIFY AND HOLD <br /> x <br /> EQ. Equal STA. Station HARMLESS THE OWNER AND THE PROJECT DESIGN TEAM FROM AND AGAINST THE 2. CONTRACTOR, ALONG WITH MECHANICAL CONTRACTOR,SHALL PROVIDE AND 18�� N � � Q <br /> EQ. Equipment STD. Standard CONSEQUENCES OF ANY UNAUTHORIZED DEVIATIONS OR OMISSIONS. SUBSTITUTION LOCATE ACCESS DOORS/PANELS IN WALL&CEILING CONSTRUCTION AS REQUIRED <br /> E.W.C. Electric Water Cooler STL Steel SUBMITTALS WILL BE CONSIDERED ONLY IF THE PROPOSED SUBSTITUTION TO PROVIDE ACCESS TO MECHANICAL,FIRE SPRINKLER,PLUMBING&ELECTRICAL LL W <br /> EXST. Existing STOR. Storage IMPROVES THE QUALITY OF THE PROJECT TO THE OWNER; AND IN NO EVENT WILL WORK. CONTRACTOR SHALL SUBMIT A PLAN OF ALL PROPOSED ACCESS PANEL <br /> EXPO. Exposed STRL. Structural THE OWNER BE REQUIRED TO AUTHORIZE A SUBSTITUTION THAT IS NOT EQUAL IN LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. �_ O O <br /> EXP. Expansion SUSP. Suspended QUALITY TO WHAT IS SPECIFIED. ILL! I- <br /> EXT. Exterior SYS. Symmetrical 3. ALL PENETRATIONS AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN J > w <br /> 10. DESIGN/BUILD CONTRACTOR SUBMITTALS WILL BE REVIEWED BY THE PROJECT RATING. J <br /> F.A. Fire Alarm TRD. Tread DESIGN TEAM,IF AT ALL,ONLY FOR CONFORMANCE WITH THE AESTHETIC <br /> F.B. Flat Bar T.B. Towel Bar ASPECTS AND MAJOR SPACE LIMITATIONS OF THE PROJECT; AND EACH 4. WHERE OCCURS, CONTRACTOR SHALL PATCH ANY EXISTING WALLS AND/OR Q LLI <br /> F.D. Floor Drain T.C. Top of Curb DESIGN/BUILD CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING: CEILINGS AS NEEDED TO REFURBISH THE LEASE SPACE AND REPAIR ALL .6 LLI <br /> FDN. Foundation TEL. Telephone DAMAGES CAUSED BY CONTRACTOR. o LLI <br /> F.E. Fire Extinguisher TER. Terrazzo A. PREPARING ALL THE ENGINEERING AND OTHER DRAWINGS AND SPECIFICATIONS a ) <br /> F.E.C. Fire Extinguisher Co. T. &G. Tongue and Groove 5. INTERIOR WALLS AND CEILINGS SHALL BE INSTALLED IN ACCORDANCE TO STATE& O <br /> 9 FOR THE COMPONENTS OF ITS DESIGN/BUILD UNDERTAKING. <br /> F.H.C. Fire Hose Cabinet THK. Thick LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE w <br /> B. COMPLYING WITH THE PROJECT'S REQUIREMENTS AND SPACE LIMITATIONS. <br /> FIN. Finish T.O.C. To of Concrete DENSITY RATINGS FOR FINISH MATERIALS. a <br /> P C. COORDINATION AND INTERFACING WITH OTHER TRADES AND CONSULTANTS. O w O <br /> FLASH. Flashin T.O.P. Top of Panel D. OBTAINING ANY REQUIRED OR APPROPRIATE APPROVALS FROM AUTHORITIES ELECTRICAL 3 O <br /> 9 T.O.R. Top of Reveal HAVING JURISDICTION OVER THE PROJECT. 6. WHEN USED, ALL NOISE BARRIER BATTS(SOUND INSULATION)AND INSULATION <br /> FLUOR. Fluorescent T.O.RC. Top of Deep Recess E. HAVING THEIR DESIGN CONSULTANTS SERVE AS THE PROFESSIONAL OF RECORD BATTS SHALL BE NON-COMBUSTIBLE AND SHALL NOT CONTAIN OR UTILIZE DESIGN BUILD- SEPARATE PERMIT 3 r <br /> F.O.C. Face of Concrete T.O.M. Top of Mullion FOR THE PORTIONS OF WORK WHICH THEY DESIGN. OZONE DEPLETING COMPOUNDS. I ILL! <br /> F.O.F. Face of Finish T.O.W. Top of Wall > <br /> F.O.M. Face of Mullion T.P. To of Pavement 7. ALL NEW CONSTRUCTION MATERIALS SHALL BE 100%ASBESTOS-FREE. w <br /> F.O.S. Face of Stud P 11. AT THE CONCLUSION OF THE CONSTRUCTION, EACH PRIME CONTRACTOR SHALL <br /> T.P.D. Toilet Paper Dispenser PROVIDE SUCH WRITTEN CERTIFICATION THAT THE CONSTRUCTION HAS BEEN it <br /> FPRF. Fireproof T.V. Television <br /> F.S. Full Size T.W. To of Wall PERFORMED IN COMPLIANCE WITH THE PROJECT'S APPROVED PLANS AND a <br /> F. Foot Size <br /> Feet p SPECIFICATIONS AS THE BUILDING OFFICIAL WITH JURISDICTION OVER THE PROJECT m <br /> FTG. Footing TYP. Typical MAY REQUIRE, OR AS THE OWNER MAY REASONABLY REQUEST. MECHANICAL <br /> PURR. Furring U.O. Unfinished 12. VERSIONS OF THESE PLANS PROVIDED IN ANY ELECTRONIC FORM ARE SUBJECT x <br /> FUT. Future U.O.N. Unless Otherwise Noted DESIGN BUILD- SEPARATE PERMIT <br /> OR. Urinal TO THE SAME PROVISION AS THE OTHER INSTRUMENTS OF SERVICE PREPARED BY <br /> GA. Gauge OR ON BEHALF OF THE PROJECT DESIGN TEAM, INCLUDING WITHOUT LIMITATION <br /> GALV. Galvanized VERT. Vertical THEIR COMMON LAW,STATUTORY OR OTHER RESERVED RIGHTS, INCLUDING 3 <br /> G.B. Grab Bar VEST. Vestibule COPYRIGHTS. A RECIPIENT IS GRANTED AT MOST A TRANSFERABLE ur <br /> OIL. Glass NONEXCLUSIVE LICENSE TO REUSE THE PLANS SOLELY FOR PROJECT PURPOSES; <br /> GND. Ground W. West AND NO RECIPIENT IS AUTHORIZED TO USE OR TO ALLOW THE USE OF ALL OR o <br /> OR. Grade W/ With ANY PORTION OF THESE PLANS FOR ANY OTHER PURPOSE,AND ANY OTHER USE w <br /> GYP. Gypsum W.C. Water Closet FOR ANY OTHER PURPOSE COULD CONSTITUTE ACTIONABLE PLAGIARISM. ANY z <br /> WD. Wood ELECTRONIC DOCUMENTS WILL BE PROVIDED IN THE RESPONSIBLE DESIGN <br /> a <br /> H.B. Hose Bibb Without PROFESSIONAL'S STANDARD FORMATS AND CONVENTIONS AND WITH NO o <br /> H.C. Hollow Core WpQ Waterproof GUARANTEE OF THE ABSENCE OF VIRUSES OR OTHER HARMFUL MATERIAL,OR OF O <br /> HDWD. Hardwood WSCT. Wainscot COMPATIBILITY WITH ANY RECIPIENT'S SOFTWARE OR HARDWARE SO THAT ANY 1.- <br /> HDWE. Hardware WT. Weight USE WITH OR CONVERSION TO THE OTHER FORMS OR CONVENTIONS,OR THE USE <br /> H.M. Hollow MetalWITH ANY PARTICULAR SOFTWARE OR HARDWARE, IS AT THE RECIPIENT'S SOLE <br /> HORIZ. Horizontal L <br /> HR. Hour RISK. m <br /> HGT. Height z < 4--, <br /> J LLI o Cn <br /> UI C: <br /> SYMBOLS LEGEND VICINITY MAP OWNER ARCHITECT DEFERRED SUBMITTALS: a ° <br /> � W L <br /> o J <br /> DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT <br /> ALIGN DETAIL REFERENCE AND ENGINEERS OF RECORD WHO SHALL REVIEW AND PROVIDE A.- <br /> OFFICE XXX r PIETROMONACO JACKSON PROPERTIES WARE MALCOMB NOTATION INDICATING DOCUMENTS HAVE BEEN REVIEWED AND FOUND w ti - <br /> OFFICE f ROOM NAME t SHEET NUMBER TO BE IN GENERAL CONFORMANCE WTH THE BUILDING DESIGN. <br /> 101 f ROOM NUMBER 7525 SE 24TH ST, STE 300 NAME: DANNY JACKSON SUBMITTAL MATERIALS SHALL INCLUDE PLANS,DETAILS AND 3 it a r <br /> t DETAIL SECTION REFERENCE CALCULATIONS PREPARED AND SIGNED BY A STATE REGISTERED a <br /> XX MERCER ISLAND,WA 98040 PH: wo <br /> O i 3015 112TH AVENUE NE, SUITE 205 KATE WITTENBROOK-HORNS ENGINEER r <br /> EMAIL: dann nw.com a ��I11 <br /> o XXX t SHEET NUMBER �'� Y�°U1P BELLEVUE. WASHINGTON. 98004 PH: 425 670-6706 CONTRACTOR SHALL SUBMIT ARCHITECT AND ENGINEER REVIEWED <br /> NEW DOOR ,20� m FAX: (425)774-8219 SUBMITTAL MATERIALS TO THE BUILDING OFFICIAL FOR REVIEW AND <br /> w PERMIT APPROVAL.DEFERRED SUBMITTAL ITEMS SHALL NOT BE z o <br /> f SECTION REFERENCE w m INSTALLED PRIOR TO OBTAINING THE BUILDING OFFICIAL'S APPROVAL <br /> DOOR NUMBER XXX > OF THE SUBMITTAL. <br /> r SHEET NUMBER < a in (O <br /> d (REFER TO DOOR Op a <br /> SCHEDULE) e t ELEVATION REFERENCE �P 92ND a w <br /> EXISTING DOOR XXX w o <br /> wo t SHEET NUMBER �W�" G C ao o m <br /> / roc FIRE EXTINGUISHER 1 ELEVATION VIEW 5 (� <br /> 1-+S CABINET w/FIRE� SKYLINE CONSTRUCTION ELEVATION REFERENCE <br /> EXTINGUISHER 4 X 2 <br /> XXX t SHEET NUMBER 99 <br /> oFE WALL-MOUNTED +.+ <br /> FIRE EXTINGUISHER 3 i i e sr se H sr_SE 330 120TH AVE NE,STE100 JOSH EATON z PA/PM: KWH/LL <br /> in n BELLEVUE,WA 98005 PH: (206)909-9466 <br /> L KEYNOTE INDICATOR e�WALL MATERIAL TYPE Q "<' m josheOskyfineconstruction.build DRAWN BY: N.GARLOCK L <br /> TYPE NUMBER ✓� w JOB NO.: SEA22-6147-01 CD <br /> p M 0. <br /> X EQUIPMENT TAG SHEET <br /> FLOOR MATERIAL TYPE N <br /> 1 r TYPE NUMBER z O <br /> PROJECT SITE s <br /> REVISION CLOUD P a l 0 ■ Q O <br /> % MISC.MATERIAL TYPE N M U <br /> 0 <br /> &DELTA NUMBER NO SCALE o <br /> N e~TYPE NUMBER <br /> 3 <br />