Laserfiche WebLink
H J K <br /> u <br /> I <br /> Hermanson <br /> ❑ ? ! t�F Building Today,Defining Tomorrow <br /> 0 UNIT MOUNTED ABOVE CEWNG WITHIN WAREHOUSE SPACE. <br /> Hermanson Company UP <br /> CONDENSATE TO NEAREST DRAIN/HUB DRAIN AT LAVATORY 1221 2nd Avenue North <br /> ENERGY ROOM SINK IN RESTROOM WITH 1"AIR GAP. Kent,Washington 98032 <br /> Tel:(206)575-9700 <br /> ( 12x12 LOUVER.RUSKIN ELF375DX OR EQUAL Fax:(206)575-9800 <br /> ® ® OPENING TO BE 10 FEEr FROM ADJACENT DRIVE AISLE(OR 25 —hermanson.com <br /> --- FEET ABOVE)AND 10 FEET FROM EXHAUST OPENINGS. Contractor Reg(E:HERMACLO05BJ <br /> Q5 SHIELDING OF UNITS,DUCTWORK,PIPING AND PENETRATIONS TO <br /> III OF= <br /> BE BY OTHERS <br /> - - - 5 <br /> LITHIUM <br /> -- LAB <br /> ' /brL <br /> IOU 101 RS SM1-40 5 F 1 D <br /> Du-1oz � m ZAP ENERGY <br /> = Du-1os z = I 5901 23RD DR. W. <br /> IDU-104 <br /> III - = I EVERETT, WA 98203 <br /> = - - - - 3 <br /> IDU-103 5SM SM1-70 _ <br /> 4 <br /> t <br /> OD <br /> ,S¢8 OR'T'A <br /> ---------_ �9 4wnsy 9 <br /> B 8 � o Ati <br /> MEN +N �149 9 <br /> 0 <br /> ONAL E <br /> OPEN <br /> OPEN [WO <br /> OFFICE October 2Z 2024 <br /> OFFICE WOMEN <br /> I I <br /> ISSUE FOR PERMIT <br /> ENTRY/ Key Plan <br /> WAITING <br /> I I <br /> OFFICE OFFICE <br /> N <br /> PARTIAL 1 ST FLOOR PLAN - HVAC <br /> SCALE: 1/8"= V-0" - <br /> !� <br /> Revisions <br /> SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE (EXISTING) LAST UPDATED: 09/18/24 SPIRAL MOUNT REGISTER SCHEDULE LAST UPDATED: 07/03/24 <br /> UNIT AREA BASIS ASSOCIATED COOLING CAPACITY BTUH HEATING CAPACITY TRI ELECCAL SOUND WEIGHT UNIT BASIS OF TYPE DUCT MAX CORE FACE THROW <br /> TAG LOCATION SERVED OF DESIGN FAN COIL UNIT TOTAL SENS. SEER BTUH HSPF/COP MCA V/PH dBA LBS REMARKS TAG DESIGN IN DIA CFM SIZE SIZE 150/100/50 INC MOUNTING MATERIAL REMARKS <br /> HP-8 CEILING OFFICE MXZ-SM48 IDU-101 THRU 1051 48000 1 36000 j 23.0 N/A I N/A 1 42 1 208-230/1 1 SM1 PRICE SDGE SUPPLY MIN 8 180 12 X 4 14 X 6 12/18/25 17 DUCT STEEL 1 2 3 4 5 <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL SM2 PRICE SDGE SUPPLY MIN 10 275 12 X 6 14 X 8 15/22/31 19 DUCT STEEL 1 2 3 4 5 <br /> PER MANUFACTURERS REQUIREMENTS SM3 PRICE SDGE SUPPLY MIN 10 365 16 X 6 18 X 8 17/25/36 20 DUCT STEEL 1.2.3.4.5 <br /> 1 EXISTING UNIT.REBALANCE AS REQUIRED. SM4 PRICE SDGE SUPPLY MIN 12 570 16 X 8 18 X 10 21/32/45 22 DUCT STEEL 1,2,3,4,5 <br /> SMS PRICE SDGE SUPPLY MIN 12 630 18 X 8 20 X 10 22/33/47 23 DUCT STEEL 1 2 3 4 5 <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS _10/25/24 BEG ISSUE FOR PERMIT <br /> PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS No. Date BY Description <br /> SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 09/18/24 <br /> UNIT BASIS OF ASSOCIATED SUPPLY OSA ESP MAX REFR ELECTRICAL SOUND WEIGHT GENERAL PROVIDE ROOM RETURN GRILLE IF>60 CFM SUPPLY FOR STANDARD DOOR WITH 1/2"MIN BOTTOM GAP OR <br /> >25 CFM SUPPLY FOR GLASS SLIDING DOOR(SEE RETURN GRILLE SCHEDULE FOR SIZE) <br /> TAG LOCATION SERVES DESIGN CONDENSER CFM CFM IN WG FT/HT MCA V/PH dBA LBS REMARKS 1 PROVIDE WITH OPPOSED BLADE DAMPER(VC53) <br /> IDU-101 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 2 REFER TO DRAWINGS FOR DUCT SIZE DIAMETER TO BE ATTACHED TO(MUST EXCEED CORE HEIGHT BY 4"MINIMUM) Design Team <br /> IDU-102 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 3 STANDARD GALVANIZED FINISH,CUSTOM COLORS ONLY IF SPECIFIED BY ARCHITECT <br /> IDU-103 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 Design BOG <br /> IDU-104 CEILING OFFICE SLZ-KAl2 HP-8 - 40 0.50 65'/40' - 208-230/1 - _ 1 4 REGISTER SHALL BE SIZED FOR CORE SIZE AND SPIRAL DUCT DIAMETER <br /> IDU-105 WALL OFFICE MSZ-GS12 HP-8 400 70 0.50 65'/4W 1.0 208-230/1 2 5 THROW BASED ON 100 FPM TERMINAL VELOCITY Drawn FVP <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL <br /> PER MANUFACTURERS REQUIREMENTS Checked DTN <br /> 1 EXISTING UNIT.REBALANCE AS REQUIRED. <br /> Pre-Construction Number 21-24-27429 <br /> 2 NEW UNIT CONNECTED TO EXISTING SYSTEM. <br /> Construction Number <br /> ENERGY RECOVERY VENTILATOR SCHEDULE LAST UPDATED: 10/18/24 Issue Date 10/25/24 <br /> TIME OUTSIDE AIR EXHAUST AIR FAN INFO WATT AHRI <br /> UNIT AREA OF CFM EAT"F LAT°F CFM EAT°F LAT°F SUPPLY FAN EXHAUST FAN PER % ELEC WGT <br /> TAG LOCATION SERVED BASIS OF DESIGN YEAR DB WB DB WB DB WB DB WB KW ESP CTRL KW ESP CTRL CFM EFFECT V/PH LBS REMARKS <br /> ERV-101 1ST FUR OFFICE LOSSNAY SUM 110 86 67 79 65 110 75 63 81 65 0.17 0.40 ECM 0.17 0.40 ECM 0.73 55% 230/1 75 1,2,3,5,7,9,10,11,12 <br /> LGH-F300RVX2 WIN 110 24 19 57 43 110 70 53 38 29 82% PARTIAL 1ST FLOOR <br /> GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& <br /> INSTALL PER MANUFACTURERS REQUIREMENTS PLAN & SCHEDULE <br /> REMARKS: - HVAC <br /> 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. <br /> MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. <br /> 2 UL/ETL LISTED UNIT. SUPPLY AND EXHAUST FAN MOTORS TO BE CAPABLE OF ADJUSTABLE SPEEDS;PROVIDE EC TYPE MOTOR IF>:1/12 HP TO<1HP AND AVAILABLE AS FACTORY OPTION <br /> 3 PROVIDE WITH EC MOTORS(70%EFFICIENT MINIMUM)AT SUPPLY AND EXHAUST FANS TO ACCOMMODATE FILTER LOADING <br /> 5 MFG TO PROVIDE MERV-14 FILTERS FOR OUTSIDE AIRFLOW SYSTEM AND MERV-7 FILTERS FOR EXHAUST AIRFLOW SYSTEM. <br /> 7 WITH 18"FACTORY CURB,ECONOMIZER CONTROL,LOW LEAKAGE MOTOR OPERATED DAMPERS,FILTER SENSOR,ROTATION SENSOR,AND SERVICE OUTLET. <br /> 9 UNIT TO OPERATE CONTINUOUSLY DURING OCCUPIED HOURS,DECOUPLED FROM CENTRAL SYSTEM PER C403.6.2 FOR CITY USE: <br /> 10 MINIMUM UNIT EFFICIENCY EX UP MEET THE ENERGY TABLE CR T M2 .01 <br /> 11 INSULATE OSA INTAKE AND EXHAUST DUCTWORK FROM EXTERIOR UP TO THE ERV UNIT,AND SUPPLY DUCTWORK IF LEAVING TEMPERATURE IS <55°F <br /> 12 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEY)AND<75 LBS OR<400 LBS WITH FLEX CONN'S&Ip=1.0&4'MAX MOUNT HEIGHT AFF <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 12/19/2024 <br /> 2, 4, <br />