5901 23RD DR W 2024 ZAP ENERGY Plans 2025-07-01
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
Plans
>
5901 23RD DR W 2024 ZAP ENERGY Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 1:51:26 PM
Creation date
6/5/2025 10:51:10 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Permit
M2411-008
Year
2024
Notes
INSTALL ONE NEW SPLIT SYSTEM FAN COIL INDOOR UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H J K <br /> u <br /> I <br /> Hermanson <br /> ❑ ? ! t�F Building Today,Defining Tomorrow <br /> 0 UNIT MOUNTED ABOVE CEWNG WITHIN WAREHOUSE SPACE. <br /> Hermanson Company UP <br /> CONDENSATE TO NEAREST DRAIN/HUB DRAIN AT LAVATORY 1221 2nd Avenue North <br /> ENERGY ROOM SINK IN RESTROOM WITH 1"AIR GAP. Kent,Washington 98032 <br /> Tel:(206)575-9700 <br /> ( 12x12 LOUVER.RUSKIN ELF375DX OR EQUAL Fax:(206)575-9800 <br /> ® ® OPENING TO BE 10 FEEr FROM ADJACENT DRIVE AISLE(OR 25 —hermanson.com <br /> --- FEET ABOVE)AND 10 FEET FROM EXHAUST OPENINGS. Contractor Reg(E:HERMACLO05BJ <br /> Q5 SHIELDING OF UNITS,DUCTWORK,PIPING AND PENETRATIONS TO <br /> III OF= <br /> BE BY OTHERS <br /> - - - 5 <br /> LITHIUM <br /> -- LAB <br /> ' /brL <br /> IOU 101 RS SM1-40 5 F 1 D <br /> Du-1oz � m ZAP ENERGY <br /> = Du-1os z = I 5901 23RD DR. W. <br /> IDU-104 <br /> III - = I EVERETT, WA 98203 <br /> = - - - - 3 <br /> IDU-103 5SM SM1-70 _ <br /> 4 <br /> t <br /> OD <br /> ,S¢8 OR'T'A <br /> ---------_ �9 4wnsy 9 <br /> B 8 � o Ati <br /> MEN +N �149 9 <br /> 0 <br /> ONAL E <br /> OPEN <br /> OPEN [WO <br /> OFFICE October 2Z 2024 <br /> OFFICE WOMEN <br /> I I <br /> ISSUE FOR PERMIT <br /> ENTRY/ Key Plan <br /> WAITING <br /> I I <br /> OFFICE OFFICE <br /> N <br /> PARTIAL 1 ST FLOOR PLAN - HVAC <br /> SCALE: 1/8"= V-0" - <br /> !� <br /> Revisions <br /> SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE (EXISTING) LAST UPDATED: 09/18/24 SPIRAL MOUNT REGISTER SCHEDULE LAST UPDATED: 07/03/24 <br /> UNIT AREA BASIS ASSOCIATED COOLING CAPACITY BTUH HEATING CAPACITY TRI ELECCAL SOUND WEIGHT UNIT BASIS OF TYPE DUCT MAX CORE FACE THROW <br /> TAG LOCATION SERVED OF DESIGN FAN COIL UNIT TOTAL SENS. SEER BTUH HSPF/COP MCA V/PH dBA LBS REMARKS TAG DESIGN IN DIA CFM SIZE SIZE 150/100/50 INC MOUNTING MATERIAL REMARKS <br /> HP-8 CEILING OFFICE MXZ-SM48 IDU-101 THRU 1051 48000 1 36000 j 23.0 N/A I N/A 1 42 1 208-230/1 1 SM1 PRICE SDGE SUPPLY MIN 8 180 12 X 4 14 X 6 12/18/25 17 DUCT STEEL 1 2 3 4 5 <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL SM2 PRICE SDGE SUPPLY MIN 10 275 12 X 6 14 X 8 15/22/31 19 DUCT STEEL 1 2 3 4 5 <br /> PER MANUFACTURERS REQUIREMENTS SM3 PRICE SDGE SUPPLY MIN 10 365 16 X 6 18 X 8 17/25/36 20 DUCT STEEL 1.2.3.4.5 <br /> 1 EXISTING UNIT.REBALANCE AS REQUIRED. SM4 PRICE SDGE SUPPLY MIN 12 570 16 X 8 18 X 10 21/32/45 22 DUCT STEEL 1,2,3,4,5 <br /> SMS PRICE SDGE SUPPLY MIN 12 630 18 X 8 20 X 10 22/33/47 23 DUCT STEEL 1 2 3 4 5 <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS _10/25/24 BEG ISSUE FOR PERMIT <br /> PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS No. Date BY Description <br /> SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 09/18/24 <br /> UNIT BASIS OF ASSOCIATED SUPPLY OSA ESP MAX REFR ELECTRICAL SOUND WEIGHT GENERAL PROVIDE ROOM RETURN GRILLE IF>60 CFM SUPPLY FOR STANDARD DOOR WITH 1/2"MIN BOTTOM GAP OR <br /> >25 CFM SUPPLY FOR GLASS SLIDING DOOR(SEE RETURN GRILLE SCHEDULE FOR SIZE) <br /> TAG LOCATION SERVES DESIGN CONDENSER CFM CFM IN WG FT/HT MCA V/PH dBA LBS REMARKS 1 PROVIDE WITH OPPOSED BLADE DAMPER(VC53) <br /> IDU-101 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 2 REFER TO DRAWINGS FOR DUCT SIZE DIAMETER TO BE ATTACHED TO(MUST EXCEED CORE HEIGHT BY 4"MINIMUM) Design Team <br /> IDU-102 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 3 STANDARD GALVANIZED FINISH,CUSTOM COLORS ONLY IF SPECIFIED BY ARCHITECT <br /> IDU-103 WALL OFFICE MSZ-GL12 HP-8 - - 0.50 65'/40' - 208-230/1 - - 1 Design BOG <br /> IDU-104 CEILING OFFICE SLZ-KAl2 HP-8 - 40 0.50 65'/40' - 208-230/1 - _ 1 4 REGISTER SHALL BE SIZED FOR CORE SIZE AND SPIRAL DUCT DIAMETER <br /> IDU-105 WALL OFFICE MSZ-GS12 HP-8 400 70 0.50 65'/4W 1.0 208-230/1 2 5 THROW BASED ON 100 FPM TERMINAL VELOCITY Drawn FVP <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL <br /> PER MANUFACTURERS REQUIREMENTS Checked DTN <br /> 1 EXISTING UNIT.REBALANCE AS REQUIRED. <br /> Pre-Construction Number 21-24-27429 <br /> 2 NEW UNIT CONNECTED TO EXISTING SYSTEM. <br /> Construction Number <br /> ENERGY RECOVERY VENTILATOR SCHEDULE LAST UPDATED: 10/18/24 Issue Date 10/25/24 <br /> TIME OUTSIDE AIR EXHAUST AIR FAN INFO WATT AHRI <br /> UNIT AREA OF CFM EAT"F LAT°F CFM EAT°F LAT°F SUPPLY FAN EXHAUST FAN PER % ELEC WGT <br /> TAG LOCATION SERVED BASIS OF DESIGN YEAR DB WB DB WB DB WB DB WB KW ESP CTRL KW ESP CTRL CFM EFFECT V/PH LBS REMARKS <br /> ERV-101 1ST FUR OFFICE LOSSNAY SUM 110 86 67 79 65 110 75 63 81 65 0.17 0.40 ECM 0.17 0.40 ECM 0.73 55% 230/1 75 1,2,3,5,7,9,10,11,12 <br /> LGH-F300RVX2 WIN 110 24 19 57 43 110 70 53 38 29 82% PARTIAL 1ST FLOOR <br /> GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION& <br /> INSTALL PER MANUFACTURERS REQUIREMENTS PLAN & SCHEDULE <br /> REMARKS: - HVAC <br /> 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. <br /> MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. <br /> 2 UL/ETL LISTED UNIT. SUPPLY AND EXHAUST FAN MOTORS TO BE CAPABLE OF ADJUSTABLE SPEEDS;PROVIDE EC TYPE MOTOR IF>:1/12 HP TO<1HP AND AVAILABLE AS FACTORY OPTION <br /> 3 PROVIDE WITH EC MOTORS(70%EFFICIENT MINIMUM)AT SUPPLY AND EXHAUST FANS TO ACCOMMODATE FILTER LOADING <br /> 5 MFG TO PROVIDE MERV-14 FILTERS FOR OUTSIDE AIRFLOW SYSTEM AND MERV-7 FILTERS FOR EXHAUST AIRFLOW SYSTEM. <br /> 7 WITH 18"FACTORY CURB,ECONOMIZER CONTROL,LOW LEAKAGE MOTOR OPERATED DAMPERS,FILTER SENSOR,ROTATION SENSOR,AND SERVICE OUTLET. <br /> 9 UNIT TO OPERATE CONTINUOUSLY DURING OCCUPIED HOURS,DECOUPLED FROM CENTRAL SYSTEM PER C403.6.2 FOR CITY USE: <br /> 10 MINIMUM UNIT EFFICIENCY EX UP MEET THE ENERGY TABLE CR T M2 .01 <br /> 11 INSULATE OSA INTAKE AND EXHAUST DUCTWORK FROM EXTERIOR UP TO THE ERV UNIT,AND SUPPLY DUCTWORK IF LEAVING TEMPERATURE IS <55°F <br /> 12 PROVIDE SEISMIC BRACING PER ACSE 7,UNLESS:UNIT<20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT(NO FLEY)AND<75 LBS OR<400 LBS WITH FLEX CONN'S&Ip=1.0&4'MAX MOUNT HEIGHT AFF <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 12/19/2024 <br /> 2, 4, <br />
The URL can be used to link to this page
Your browser does not support the video tag.