Laserfiche WebLink
T EXIT FMTI CURRENT SPACE OCCUPANCY: N <br /> _____ CURRENT SPACE OCCUPANCY(B-OFFICE&S-1 WAREHOUSE)TO REMAIN AS <br /> 2 2 NOTED IN PLAN. NO CHANGE. <br /> 1 � i LEGEND: V <br /> OCCUPANCY LU <br /> I RM ROOM USE <br /> ' 20030L 6E ROOM AREA <br /> 1. OCCUPANT LOAD <br /> EXIT EXIT <br /> ' I T EXIT <br /> OCCUPANT LOAD 10 <br /> r FACTOR N L................. Q 2 Q I I ® EXIT SIGN Y <br /> r FIRE EXTINGUISHER CABINET V7 <br /> LU <br /> �.E. FIRE EXTINGUISHER LLJ <br /> t I CR CARD READER Z q. <br /> 3 <br /> 00 <br /> ADA CLEAR SPACE PER ICC/ANSI A117.1 N O` <br /> SECTION 305 Q <br /> L <br /> ADA CLEAR TURNING RADIUS PER ICC/ANSI A117.1 N N <br /> SECTION 305(2009 VERSION) <br /> o 0 0 0 0 o I ACCESSIBLE PARKING STALL PER ICC/ANSI A117.1 P m <br /> I6�1 SECTION 502 <br /> ir EXIT EXIT DISCHARGE <br /> 0 OrI <br /> EXI ` ' COMMON PATH'0F'EGRESS TRAVEL - -- - - _ <br /> FE X 71 LENGTH OF EXIT <br /> [ACCESS TRAVEL ` 'EXIT ACCESS TRAVEL DISTANCE EVERETT COMMERCE CTR A <br /> 225-8 Floor 1 &2 <br /> I6611 Associated Blvd <br /> I CODE NOTES: Everett,WA 98203 <br /> 1. MEANS OF EGRESS ILLUMINATION:THE MEANS OF EGRESS(EXIT <br /> PATHWAY)AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT <br /> I ALL TIMES THE BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT DESIGN JPC <br /> LESS THAN 1-FOOT CANDLE(10 LUX)AT THE WALKING SURFACE DRAWN VZ <br /> LEVEL PER SBC 1008. LIGHTING MUST BE PROVIDED WITH EMERGENCY <br /> WAREHOUSE r BATTERY BACK-UP PER SBC 1008.2.1 CHECKED AC <br /> S-1 81734 SF I 2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL NO. 24-0444 <br /> I. 1630IL r ENGINEER ACCORDING TO APPLICABLE CODES/ORDINANCES IN <br /> JURISDICTION.THE ENGINEER MAY REFERENCE THIS CODE SUMMARY <br /> SHEET. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF <br /> THE ENGINEER TO COMPLETE A SCOPE OF WORK ADDRESSING ALL REGISTERED <br /> r EGRESS LIGHTING I.E.; ROOMS,SPECIALIZED SPACES,PATHWAYS,ETC. ARCHITECT <br /> I PER THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING DESIGN <br /> SUBJECT TO BUILDING OFFICIAL DISCRETION. <br /> , 4.0 <br /> 3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN OF WASHINGTON <br /> IUNLOCKED DURING AN EVENT/EMERGENCY PER SBC 1010.2.11. <br /> a o o e o 0 4. NON-EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO <br /> I REMAIN LOCKED DURING AN EVENT/EMERGENCY. DOOR CAN STILL BE <br /> OPENED WITH A KEY DURING SUCH EVENT/EMERGENCY. <br /> r 5. FIRE EXTINGUISHERS MUST BE WITHIN A 75'MAXIMUM TRAVEL <br /> DISTANCE OF ANY LOCATION. PER SBC 906.3. <br /> 0FEAT 6. ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS (OR 750 SF)TO BE <br /> O CONSIDERED B OCCUPANCY PER IBC 303.1.2. <br /> E%IT LENGTH OF EXIT <br /> r ACCESS TRAVEL 7. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0" <br /> 125'-8" OR LESS AS ALLOWED PER IBC TABLE 1017.2. EXIT TRAVEL DISTANCE <br /> SHALL BE MEASURED TO EXIT DISCHARGE OR EXIT STAIR, BUT <br /> CONTINUE DOWN A EXIT ACCESS STAIR. <br /> 8. DEAD-END CORRIDORS TO BE LESS THAN 20'-0"PER IBC 1020.4. <br /> 3 3 z o 09.16.24 PERMIT ISSUE <br /> p CODE CALCULATIONS <br /> IO � 1 1. REQUIRED EGRESS WIDTH: <br /> zE 1.1. EGRESS WIDTHS REQUIRED PER 2021 IBC 1005.3.1 & 1005.3.2: <br /> r 1.2. STAIRS:0.3"/OCCUPANT <br /> I Oyu O ® ® 1.3. OTHER COMPONENTS: 0.2"/OCCUPANT <br /> 2. TOTAL OCCUPANTS IN FLOOR 1: 299 <br /> OFFICE r ,s <br /> B 1,392 SF 3. OTHER EGRESS COMPONENTS WIDTH REQUIRED: 299 *0.2 = 59.8". <br /> 1:150 90L 59.8"/13 EXITS=4.6"MINIMUM PER EXIT. 32"MINIMUM WIDTH IS <br /> --0-------------------- O --------------------------- '" CO -�H OF ® �O� PROVIDED AT ALL EXIT DOORS TO EXTERIOR. <br /> TRA EL 44'-11" 4. (2)MINIMUM EXITS REQUIRED PER 2021 IBC 1006.3.1. <br /> EXIT EXIT LENGTH 0 EXIT EXR LENGTH OF EXIT cmai EXIT LENGTH OF EXIT (13) EXITS HAVE BEEN PROVIDED. <br /> ACCESS TRAVEL ACCESS TRAVEL ate° "",,"a ACCESS TRAVEL <br /> 234'-10" 134'-6" BREAK ROOM N CONF ROOM 115'-5" 5. "COMMON PATH OF EGRESS TRAVEL"FOR B&S-1 OCCUPANCIES <br /> B 6685E B 1,232 SF TO BE 100'-0"OR LESS AS ALLOWED PER 2021 IBC TABLE <br /> FLOOR 1 OCCUPANT LOAD: FLOOR 1 PLUMBING CALCULATIONS (PER 2021 IBC TABLE 2902.1) 5 4soL 5 sea 1006.2.1. <br /> /� Floor 1 Exit Plan 6. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-C <br /> REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR OCCUPANCY WATER CLOSETS LAVATORIES DRINKING FOUNTAINS OR LESS AND"EXIT ACCESS TRAVEL DISTANCE"FOR S-1 <br /> Square Occupant TYPE LOAD RATIO MALE RATIO FEMALE RATIO MALE FEMALE RATIO COUNTS ' , Scale: 1/16"=1'-0" OCCUPANCY TO BE 250'-0"OR LESS AS ALLOWED PER 2021 IBC <br /> Occupancy Room Name Footage Load Factor Load TABLE 1OHY <br /> 1 PER 25 1 PER 25 1 PER 40 <br /> S-1 WAREHOUSE 81,734 500 163 FOR THE FOR THE FOR THE JURISDICTION STAMP <br /> B OFFICE 1,392 150 9 B 136 FIRST 50, (�' FIRST 50, 0.9 FIRST 80, 0.56 0.56 1 PER 100 OAS <br /> THEN 1 THEN 1 THEN 1 <br /> B CONFERENCE 102& 1 pap 15 82 PER 50 PER 50 PER 80 EXIT PLAN KEY NOTES: <br /> 104 B BREAK ROOM ,23 15 45 S-1 163 1 PER 100 0.53 1 PER 100 0.53 1 PER 100 0.53 0.53 11,P0 PER 0.11 O PEIRTFIRE MARSHAL INSTRUCTION.STANDARD <br /> FIRE EXTINGUISHER PER PLAN AND/OR Exit Plan & Codes <br /> REQUIRED TOTALS 2 2 2 2 1 NOTES: O EXISTING/NEW BUILDING STANDARD EXIT LIGHTS PER RCP AND/OR PER Summary <br /> TOTAL 85,026 299 PROVIDED TOTALS 8 8 5 5 2 1. URINALS MAY BE SUBSTITUTED FOR UP TO 75%OF REQUIRED WCS IN MENNS FACILITIES PER WA. STATE IBC AMENDMENT 2902.1.1.2. FIRE MARSHAL INSTRUCTION. <br /> 2. URINALS MAY BE SUBSTITUTED FOR UP TO 25%OF REQUIRED WCS IN GENDER NEUTRAL FACILITIES, PER WA. STATE AMENDMENT 03 ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. <br /> 2902.1.1.3. <br /> 3. IN OCCUPANCIES THAT REQUIRE MORE THAN TWO DRINKING FOUNTAINS PER FLOOR OR SECURED AREA,BOTTLE FILLING STATIONS MAY BE ® ALL NEW COUNTERS ARE 34"HIGH PER ICC/ANSI A117.1 SECTION 902. <br /> SUBSTITUTED FOR UP TO 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS PER WA. STATE IBC AMENDMENT 2902.5.4.2 <br /> 4. DRINKING FOUNTAINS ARE NOT REQUIRED WITHIN INDIVIDUAL TENANT SPACES IF LOCATED ON AN ACCESSIBLE ROUTE WITHIN 500 FEET OF I O. <br /> THE MOST REMOTE LOCATION WITHIN THE TENANT SPACE PER WA. STATE AMENDMENT 2902.5 <br /> ©2W4 JPc ARCHITECTS uc <br /> City of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/07/2024 <br />