Laserfiche WebLink
T CURRENT SPACE OCCUPANCY: N <br /> CURRENT SPACE OCCUPANCY(B OFFICE&S-1 WAREHOUSE)TO REMAIN AS <br /> NOTED IN PLAN. NO CHANGE. 1 <br /> 11 LEGEND: V <br /> OCCUPANCY W <br /> ROOM USE <br /> RM <br /> 2005E ROOM AREA <br /> 1:150 1.30L OCCUPANT LOAD <br /> OCCUPANT LOAD <br /> FACTOR O <br /> N <br /> ® EXIT SIGN <br /> L FIRE EXTINGUISHER CABINETLn <br /> V <br /> �.E. FIRE EXTINGUISHER LU <br /> CR CARD READER Z p <br /> q)C3 <br /> 7 CD <br /> L ADA CLEAR SPACE PER ICC/ANSI A117.1 N O` <br /> L_J SECTION 305 Q <br /> L <br /> /- O�• ADA CLEAR TURNING RADIUS PER ICC/ANSI A117.1 N N <br /> 7 SECTION 305(2009 VERSION) > <br /> O d <br /> ACCESSIBLE PARKING STALL PER ICC/ANSI A117.1 M P m <br /> O 13 <br /> SECTION 502 <br /> EXIT EXIT DISCHARGE <br /> �7OMMON PATH OF EGRESS TRAVEL -- - - - <br /> + t7 ACCESS TRAVEL DISTANCE EVERETT COMMERCE CTR A <br /> Floor 1 &2 <br /> 6611 Associated Blvd <br /> CODE NOTES: Everett,WA 98203 <br /> 1. MEANS OF EGRESS ILLUMINATION:THE MEANS OF EGRESS(EXIT <br /> PATHWAY)AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT <br /> ALL TIMES THE BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT DESIGN JPC <br /> LESS THAN 1-FOOT CANDLE(1 0 LUX)AT THE WALKING SURFACE DRAWN VZ <br /> CONE ROOM LEVEL PER SEC 1008. LIGHTING MUST BE PROVIDED WITH EMERGENCY <br /> BATTERY BACK-UP PER SBC 1008.2.1 CHECKED AC <br /> B 326 SF 2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL NO. 24-0444 <br /> ENGNEER ACCORDING TO APPLICABLE CODES/ORDINANCES IN <br /> 1:1 5 22 OL J IURSDICTION.THE ENGINEER MAY REFERENCE THIS CODE SUMMARY <br /> SHEET. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF REGISTERED <br /> JAN CONFERENCE THE ENGINEER TO COMPLETE A SCOPE OF WORK ADDRESSING ALL r <br /> M N WOMEN CLST OFFICE OFFICE OFFICE ROOM OFFICE EGRESS LIGHTING I.E.; ROOMS,SPECIALIZED SPACES,PATHWAYS,ETC. ARCHITECT <br /> 216 214 212 210 208 206 204 pp2 PER THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING DESIGN _... <br /> SUBJECT TO BUILDING OFFICIAL DISCRETION. <br /> C RLOTTE ATT ON <br /> F <br /> n 3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN STATE OF WASHINGTON <br /> O 0 � � UNLOCKED DURING AN EVENT/EMERGENCY PER SBC 1010.2.11. <br /> O C 4. NON-EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO <br /> u REMAIN LOCKED DURING AN EVENT/EMERGENCY. DOOR CAN STILL BE <br /> QQ OPENED WITH A KEY DURING SUCH EVENT/EMERGENCY. <br /> 5. FIRE EXTINGUISHERS MUST BE WITHIN A 75'MAXIMUM TRAVEL <br /> DISTANCE OF ANY LOCATION. PER SBC 906.3. <br /> 6. ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS (OR 750 SF)TO BE <br /> CONSIDERED B OCCUPANCY PER IBC 303.1.2. <br /> DN 1 F 1 2 7. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0" <br /> �A OR LESS AS ALLOWED PER IBC TABLE 1017.2. EXIT TRAVEL DISTANCE <br /> COMMON PATH <br /> T OF SHALL BE MEASURED TO EXIT DISCHARGE OR EXIT STAIR, BUT <br /> _ ,1 _ CONTINUE DOWN A EXIT ACCESS STAIR. <br /> T <br /> L JO RAVEL 54'-1 0' ENTRY 8. DEAD-END CORRIDORS TO BE LESS THAN 20'-0"PER IBC 1020.4. <br /> 4 LANDING <br /> 200 <br /> DN <br /> SERVER 09.16.24 PERMIT ISSUE <br /> STAIR <br /> 1,9 F E ZZs CODE CALCULATIONS <br /> db <br /> B 2,945S F <br /> 1. REQUIRED EGRESS WIDTH: <br /> 1:150 20 OIL 1.1. EGRESS WIDTHS REQUIRED PER 2021 IBC 1005.3.1 & 1005.3.2: <br /> OPEN 1.2. STAIRS:0.3"/OCCUPANT <br /> BREAK ROOM TO BELOW 1.3. OTHER COMPONENTS: 0.2"/OCCUPANT <br /> 2. TOTAL OCCUPANTS IN FLOOR 2:69 <br /> B 41 9 SF 3. OTHER EGRESS COMPONENTS WIDTH REQUIRED: 69*0.2 = 13.8". <br /> 1:15 28 OL 13.8"/2 EXITS= 6.9"MINIMUM PER EXIT. 32"MINIMUM WIDTH IS <br /> PROVIDED AT ALL EXIT DOORS TO STAIRWELL. <br /> a 4. (2)MINIMUM EXITS REQUIRED PER 2021 IBC 1006.3.1. <br /> BREAK EN ROOM �.'FPF LPRPNT OPEN (2)EXITS HAVE BEEN PROVIDED. <br /> COLLAROO 2IN 224 5. "COMMON PATH OF EGRESS TRAVEL"FOR B OCCUPANCY TO BE <br /> 100'-0"OR LESS AS ALLOWED PER 2021 IBC TABLE 1006.2.1. <br /> FLOOR 2 OCCUPANT LOAD: FLOOR 2 PLUMBING CALCULATIONS /\ Floor 2 Exit Plan 6. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0" <br /> REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR OCCUPANCY WATER CLOSETS LAVATORIES DRINKING FOUNTAINS OR LESS AND"EXIT ACCESS TRAVEL DISTANCE"FOR <br /> Scale: 1/8"=1'-0" OCCUPANCY TO BE 250'-0"OR LESS AS ALLOWED PER <br /> 2021 IBC <br /> Occupancy Room Name square Load Factor Occupant TYPE LOAD RATIO MALE RATIO FEMALE RATIO MALE FEMALE RATIO COUNTS TABLE 1017.2. <br /> Footage Load 1 PER 25 1 PER 25 1 PER 40 <br /> B OFFICE 2,945 150 20 FOR THE FOR THE FOR THE JURISDICTION STAMP <br /> B 69 FIRST 50, 0.9 FIRST 50, 0.9 FIRST 80, 0.56 0.56 1 PER 100 0.45 <br /> B CONFERENCE 204 326 15 22 THEN 1 THEN 1 THEN 1 <br /> PER 50 PER 50 PER 80 EXIT PLAN KEY NOTES: Exit Plan & Codes <br /> B BREAK ROOM 419 15 28 REQUIRED TOTALS 1 1 1 1 0 Oj EXISTING/NEW BUILDING STANDARD FIRE EXTINGUISHER PER PLAN AND/OR <br /> PROVIDED TOTALS 3 3 2 2 2 PER FIRE MARSHAL INSTRUCTION. Summary <br /> TOTAL 3,690 69 NOTES: O EXISTING/NEW BUILDING STANDARD EXIT LIGHTS PER RCP AND/OR PER <br /> 1. URINALS MAY BE SUBSTITUTED FOR UP TO 75%OF REQUIRED I WCS N MENNS FACILITIES PER WA. STATE IBC AMENDMENT 2902.1.1.2. FIRE MARSHAL INSTRUCTION. <br /> 2. URINALS MAY BE SUBSTITUTED FOR UP TO 25%OF REQUIRED WCS N GENDER NEUTRAL FACILITIES, PER WA. STATE AMENDMENT O3 ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. <br /> 2902.1.1.3. <br /> 3. IN OCCUPANCIES THAT REQUIRE MORE THAN TWO DRINKING FOUNTAINS PER FLOOR OR SECURED AREA,BOTTLE FILLING STATIONS MAY BE ® ALL NEW COUNTERS ARE 34"HIGH PER ICC/ANSI A117.1 SECTION 902. <br /> SUBSTITUTED FOR UP TO 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS PER WA. STATE IBC AMENDMENT 2902.5.4.2 <br /> 4. DRINKING FOUNTAINS ARE NOT REQUIRED WITHIN INDIVIDUAL TENANT SPACES IF LOCATED ON AN ACCESSIBLE ROUTE WITHIN 500 FEET OF 0. /� <br /> 4 THE MOST REMOTE LOCATION WITHIN THE TENANT SPACE PER WA I. STATE AMENDMENT 2902.5 <br /> ­4 uc <br /> City of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/07/2024 <br />