DEMOLITION NOTES ENERGY NOTES A4.1 A4.1 <br /> 1.ALL DEMOLITION WORK SHALL BE PERFORMED WITH'DUE CARE AND ENERGY CODE COMPLIANCE SHALL BE AS PER THE WASHINGTON STATE ENERGY <br /> DILIGENCE'SO AS TO PREVENT THE ARBITRARY DESTRUCTION OF ADJACENT CODE 2015.MINIMUM INSULATION(R)VALUES OR U-VALUES OF COMPONENTS SHALL <br /> CONSTRUCTION DESIGNATED TO REMAIN. BE AS FOLLOWS: 10-8" 3'-3" 8'-4" 21'-101. .... <br /> 2.CARE SHALL ALSO BE TAKEN TO PREVENT THE INTERRUPTION OF GLAZING,VERTICAL(U-VALUE) 0.22 MIN. <br /> CONCEALED UTILITIES WHICH ARE TO REMAIN. DOOR,ENTRANCE(U-VALUE) 0.22 MIN. <br /> 3.ANY UTILITIES DISCOVERED DURING THE DEMOLITION PROCESS WHICH CEILING INSULATION(ATTIC) R-09 MIN. r? <br /> WERE PREVIOUSLY UNIDENTIFIED SHALL BE REPORTED TO THE ARCHITECT CEILING NSULATION(VAULTED) I R-49 MN. <br /> BEFORE REMOVAL OR DISCONNECTION. INSULATED WALLS R-21 MN INT PLUS R-12 CI = b <br /> SLAB EDGE R-10 ATTIC, v 0 N <br /> = O N 0 <br /> 4.REMOVE ALL EXISTING CONSTRUCTION AS DESIGNATED ON DEMOLITION FLOOR R-38 MIN. _ J m N <br /> PLAN. -.......... ......�...,...„ ._,....,,: ..,, - - - <br /> ENERGYCREDITNOTES(3.5 CREDITS NEEDED): ""' II��- II '' '" °D `" �'�- " ' "` "" "' "'"� "�"` J 0m <br /> 1.OPTION 1D-EFFICIENT BUILDING ENVELOPE:PRESCRIPTIVE COMPLIANCE IS BASED w ® R D <br /> 5.PATCH EXISTING CONSTRUCTION TO REMAIN TO MATCH EXISTING ADJACENT ON TABLE R4 CREDITS) <br /> WITH THE FOLLOWING MODIFICATIONS:VERTICAL FENESTRATION <br /> CONSTRUCTION AND FINISHES UNLESS NOTED OTHERWISE. U=0.22,(2.0 CREDITS) DE K i F 0 <br /> 6.WHERE EXISTING DOORS AND WINDOWS ARE DESIGNATED TO BE REMOVED, w -D Dar�re w Z 11 <br /> 2.OPTION 3d-HIGH EFFICIENCY HVAC EQUIPMENT:DUCTLESS SPLIT SYSTEM HEAT b b 5'H.TEMP.GLASS b B W <br /> PATCH OPENING WITH CONSTRUCTION TO MATCH EXISTING ADJACENT PUMPS,ZONAL CONTROL:IN HOMES WHERE THE PRIMARY SPACE HEATING SYSTEM IS _ ttj -- SHOWER ENCL ? L- j S� <br /> CONSTRUCTION UNLESS NOTED OTHERWISE. ZONAL ELECTRIC HEATING,A DUCTLESS HEAT PUMP SYSTEM SHALL BE INSTALLED 6'-0' b F V W 10� <br /> AND PROVID HEATING TO THE LARGEST ZONE OF THE HOUSING UNIT(1.0 CREDITS) °' NEW M.BATH R�1 v v <br /> 7.ALL EQUIPMENT SUCH AS PLUMBING FIXTURES,ELECTRICAL FIXTURES AND ? / W 0 1 1 <br /> REMOVED <br /> THE BE TURNED OVER TO THE OWNER OR STORED AS DIRECTED �M f� OSVX6'8" r I r I w TF r H n <br /> SHALL 3.OPTION 5a-EFFICIENT WATER HEATING:ALL SHOWERHEAD AND KITCHEN SINK - "f _ <br /> In <br /> BY <br /> FAUCETS INSTALLED.IN THE HOUSE SHALL 8E RATED AT 1.75 GPM OR LESS.ALL 1 r <br /> OTHER LAVATORY FAUCETS SHALL BERATED AT 1.0 GPM OR LESS.0.5 CREDITS �- Yw O/lrS+Db I, N 1 <br /> rlir oC aQz <br /> FLOOR PLAN NOTES FDN. VENT CALCS _ SP�T`WAC TIC I'� W a >3� <br /> V ;i/ iv SYSTEM 1[= II w i V Q Q m <br /> VENTING REQ.=1/150 SF I n,SE - - SAUNA NEW MASTER BEDRM. Tb LI ire_) ¢o V u 3 n <br /> 1.ALL DIMENSIONS ARE FROM FACE-OF-STUD TO FACE-OF-STUD,AND FACE-OF-BLOCK {"" <br /> NEW CRAWL SPACE AREA I SF=235 SF/150 SF 1b N d j1 MA \ -lio fI I'I=4-1� �w �J QwN <br /> TO FACE-OF-BLOCK(U.N.O.) r ` r Z <br /> REQUIRED SF OF VENTING=1.5 SF ►1 ? i i II vi H O 0.H N <br /> 2.ALL LUMBER TO BE DOUGLAS FIR#2 OR BETTER(U.N.O.) p. RD q `� I CC <br /> FOUNDATION VENTS-2 MIN @1.00=2 SF ` 1p -rz ill z N <br /> TOTAL VENTING PROVIDED=2 SF>1.5 SF,OKAY 3 = l L am d <br /> 3.ALL FINISH MATERIALS NOT SPECIFIED TO BE COORDINATED WITH OWNER ANDIOR �, 'i I LfI l i 1 ¢ {� N c 3 <br /> ARCHITECT. NEW CRAWL SPACE AREA 2 SF=83 SFI150 SF b Q r i+ - 8'-T, 5'•8" E <br /> liREQUIRED SF OF VENTING=0.5 SF io ai a //o I/oL7 S40ge A(-44mI .L ; o4.PROVIDE SOLID BLOCKING BEHIND ALL FIXTURES AND WALL MOUNTED Q - _ p u wACCESSORIES. FOUNDATION VENTS-1 MIN.0 1.00=1 SF "a < <br /> TOTAL VENTING PROVIDED=1 SF`+0.5 SF,OKAY b - = NEW BONUS RM. m //VTrG2CONNEC>�O 6111�BS4F3E 8 0 BS < 1,{l., 10 o <br /> 5.ANY WALLS THAT ARE MODIFIED,REPLACE GYP.BD.W15I8"TYPE'X'GYP.BD. NOTE: - a0 z coi g� <br /> 1.PROVIDE 6 MIL VAPOR RETARDER OVER ALL GROUND SURFACES IN UNDER i2 z i <br /> M of <br /> 6.WHERE(E)STUD WIDTHS VARY FROM NEW WALL TYPE STUD WIDTH,MATCH(E) p ( ) t^w <br /> STUD WIDTH. 2.PROVIDE 24"W ACCESS TO EXIST CRAWL SPACE FROM NEW �1 b 30'XB'8 3 0 X68 3 X6 8 b o= <br /> FLOORAREA. o <br /> 2.PLACE VENTS TO PROVIDE CROSS VENTILATION. L.FFI.� <br /> o; <br /> 7.PROVIDE WALL 8 FLOOR STOPS AT DOORS AS REQUIRED. 3.PROVIDE 18"x24"MIN.CRAWL SPACE ACCESS. a m00 <br /> IL <br /> 4.ADD ADDITIONAL VENTS TO REPLACE ANY VENT COVERED BY ADDITION CL. I CL. <br /> 8.(R WALLS REQUIRING OPENINGS TO BE INFILLED SHALL MATCH(E)CONSTRUCTION w <br /> 8 FIRE RATING. b �- - - - y <br /> 9.OWNER MAY OPT TO PHASE UPPER LEVEL FINISHES SEPARATELY IN ORDER TO WA L L L E G E N D m - "`"" '0"XS'0 ":��,-•- '0"XS'0' _...:.�;...,. •- .._ --.- - ...:.::... .....:. w LL <br /> OCCUPY THE LOWER LEVEL.IN THIS CASE,THE UPPER LEVEL WILL REMAIN ro z <br /> UNOCCUPIED AT THE COMPLETION OF PHASE 1 AND THE UPPER LEVEL FINISHES WILL O <br /> BE PHASE 2. 6"EXTERIOR STUDWALL-2X6 ATTIC ATTIC �- <br /> @16"OC WISIDING 01 ZIP 5 0 0 <br /> SYSTEM R-SHEATHING(R-8.6) T o <br /> 0/HOUSE WRAP 0/PLYW'D ON a <br /> EXT.FACE,11T GYP.BD.O/ 16'-9" 5'-4" IT-7" 8'.3" <br /> VAPOR BARRIER AT INSIDE <br /> DEMO WALL LEGEND FACEAND R-21 BATTS MIN. o <br /> BTWN,U.N.O. 2 �� <br /> ••_--*=^• 4"INTERIORSTUDWALL-2X4� o <br /> 161 W/1/2"GYP.BD.EA.SIDE 3 NEW UPPER LEVEL PLAN <br /> --- AND SOUND BATT INSUL.BTWN. - o <br /> --- DEMOLISHED U.N.O. USE 2X6 WHERE NEC.FOR <s <br /> NEW ADDITION,TYP. z5 <br /> PLUMBING U.N.O. F <br /> EXISTING TO REMAIN U.N.O. EXISTING WALLS TO REMAIN 12-e' 10'-8" 2'-8" 5'-4" 2'-0" 10'-9" cis <br /> U.N.O. <br /> A4.1 g,_4„ OL <br /> S EXTERIOR STUDWALL-2X6Q <br /> -. 16"OC-1 HR.FIRE RATED(SEE <br /> DETAIL 1 ON P.A9.2) 1-10""� s z <br /> 41'-10" z <br /> ry N)4'0"X1'0"FX 80 <br /> . 2'0' 0"SH( )4�. 1,8,• N 2' 'X60" Y0"XW,O"SH(N)4,0" 1,6"FX N 2'0' <br /> (DPTI Ll U C <br /> .. ,�^ _ ___.- N50 0'SL i <br /> I H U <br /> J I : Lu <br /> o BEDRM.2 o �I (E) E BATH 1 z m q x N <br /> I I I y ( (E)BEDRM.1 e o z w <br /> (E)BATH :I 11 LJ N :7� `'`' I 0 rn <br /> NEW 56 DIA PREMED. VoL7 SM-K.6�41 0 s J Q <br /> (E)BEDRM.2 1, _. I I I�1 (E)BEDRM.1 111 )),}� b tip AREA METAL IRC COMPLIANT m �A <br /> _ LJJJ III 1,Jn 15�' STAIR;STAIR N7/7H oh rrg [?�('if!-(.� z ra� v/ F� <br /> -�L� 3('N ulpl aR�, 6. 1. 'v PROVI MANUCTUOP <br /> RERTO 00 Lu t <br /> DRAWING$��/�� � � ........, �-� ¢z N > <br /> 11 \=-�• I �i SH <br /> (N)2,8„ ,8" <br /> (E)28"X8 B z W <br /> ...._._ __ ....5'0.X6V'POCKET <br /> SL_ J DECK .SD C M F- % a x I�i1 p 1D O <br /> _- -_._C-_�-- a n 7FW Y M/fGY 1`1 <br /> WA.Ir 00'fSroS a i m PANTRY T <br /> NEW BATH 2 a e= �o b z <br /> C eta - a <br /> 1I1 REMOVE EXIST.WALLS �__ z x a <br /> SHADED AREA.REMOVE 11 PER.LEGEND f Z n �, g (N)30X88' <br /> AND REPLACE EXIST. I� (E)DINING aD <br /> FOUNDATION IF I 1 D-k� 1 v <br /> NECESSARY 1 - <br /> I it (E)ENTRY A4., <br /> 8" 10'-5 6'-4" 8'-4 <br /> __ _ <br /> �E-� ---- - <br /> O U <br /> (E)KITCHEN ❑ y a F- <br /> T' AREA 2 : a 2 <br /> I e 6 3" a'-r' LIVING RM. U Z <br /> L IOo CLM F�� o U 4 <br /> (E)LNDY. (E)KITCHEN �^^ (E)LIVING RM. III Z �7o e✓rsyy` ,� 0 F <br /> I vll III w m 12'-7' D_ <br /> I 11- III m z DUCTLESS CONDENSER Z <br /> IQ Q11 I1 SPLIT HVAC SCREEN AS <br /> - �I b SYSTEM NECESSARY vJ w <br /> " e <br /> NH\1 P__________J I PANTRY <br /> i I L�rJI I �I :r-t 0 03 0 N <br /> 2 8' 8„ (N)2,0'1 <br /> 4,0„SH (N)4'0'X4'0"SL 3,-8„ 4 5 N F <br /> 6'-5" 17'-1" 20'-5" �' O a0 I <br /> 2 2 u- a <br /> AMAIN LEVEL DEMO PLAN MAIN LEVEL PLAN N W <br /> 114"=1'-0" 2 1f4"=1'-0" <br /> CI OF EVERETT O 0 CV o <br /> REVIEWED FOR PERMIT Z N Q 0 <br />