Laserfiche WebLink
INTERIOR WALL SCHEDULE WALL BLOCKING KEY WALL SHEATHING KEY KEYED NOTES GENERAL NOTES <br /> TAG DESCRIPTION INSULATION NOTES SYMBOL ITEM WEIGHT HEIGHT A.F.F. APPROX.WIDTH SYMBOL DESCRIPTION <br /> GENERIC TYPE 1-2 1/8"FURRING WORKROOM 128 LBS 36"TO 40" INDICATES SHEATHING 1. ALIGN FACE OF FINISHED WALL. A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS <br /> WALL O HAND SINK (58 KG) (915MM TO 1015MM) 30"(780MM)BEHIND SINK TRANSITION 2. ELECTRICAL PANEL LOCATIONS.MAINTAIN MINIMUM ANY D SCREPANCIES PRIOR TO CONSTRUCTION. <br /> AL OFZr <br /> 2-F•N 3 5/8"20 GA STUD FURRING WALL NONE FULL HT.WALL.SEE PLAN FOR WALL SHEATHING. SHELVES ABOVE 200 LBS 48"TO 78" 96"(2440MM)CENTERED ABOVE 5/8"GYP.WALL BOARD CLEARANCE AS REQUIRED BY CODE. DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM <br /> 3 GENERIC TYPE 3.4 7/8"WALL O COMPARTMENT SINK (91 KG) (1220MM TO 1930MM)I COMPARTMENT SINK O (FULL WALL HEIGHT) POINT. <br /> 3-F-N 3 5/8"20 GA STUDS 0 16"O.C. NONE FULL HT.WALL,SEE PLAN FOR WALL SHEATHING. UPPER 5/8"GYP.WALL BOARD 3. FUR OUT INTERIOR FACE OF WALL. <br /> C <br /> 3-T-A 3 5/8"20 GA STUDS @ 16"O.C. ACOUSTIC TERMINATE 8"ABOVE CEILING.PROVIDE 45 DEGREE WIRE SHELVES BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR O (TERMINATE AT 6"(150MM) B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED <br /> METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO ABOVE CEILING) WOOD STUD BLOCKING,OR EQUIVALENT TO SUPPORT <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. Op SHELVES AT 300 LBS 32"TO 96T OD C N ERED ACX ANY WALL ATTACHMENT AND/OR SIGNAGE. <br /> MANAGER'S DESK (138 KG) (810MM TO 2440MM) PLYWOOD,CENTERED ON BOARD <br /> RD(TERMINATE <br /> BACKER <br /> 3•T-N 3 5/8"20 GA STUDS(Z�18"O.C. NONE TERMINATE 8"ABOVE CEILING.PROVIDE T DEGREE SHELVES O BOARD(TERMINATE AT 6" C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO 150MM ABOVE CEILING ©zozz sraasucKs caeree coeaarry <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. O EQUIPMENT RACK AT 300 LBS 44"TO 98" 28"(710MM)3/4(19MM)ACX ( ) ) EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE <br /> MANAGER'S DESK (138 KG) (1120MM TO 2440MM) PLYWOOD,CENTERED ON RACK 5/8"CEMENTITIOUS BACKER CODE,REMOVE AND REPLACE WITH ACCESSIBLE STARBUCKS <br /> A STUDS 16"O.C. ACOUSTIC TERMINATE 8"ABOVE CEILING.PROVIDE T DEGREE METRO BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR.IN- BOARD(TERMINATE AT FINISH THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL <br /> METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO TRANSITION AS SHOWN ON CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. O SHELVES WALL BLOCKING PREFERRED,HOWEVER EXISTING FRP FINISHED O 2401 UTAH AVENUE SOUTH <br /> WALL MAY RECEIVE SURFACE MOUNTED,PAINTED WHITE. INTERIOR ELEVATION W/5/8" WITH A SLOPE NO GREATER THAN 1:12. <br /> ORESTROOM 200 LES 30"TO 38" 80"(1525MM)AROUND WATER GYP.WALL BOARD ABOVE SEATTLE206)31 -1575 8134 <br /> GRAB BARS (91 KG) (760MM TO 915MM) CLOSET (FULL WALL HEIGHT D. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS (206)318-1575 <br /> 5/8"PLYWOOD SHOWN OR NOTED OTHERWISE. <br /> RESTROOM 200 LBS COMMERCIAL INSTALLATION REQUIRES CONCEALED <br /> H HAND SINK (91 KG) ARM CARRIER.REFER TO MFR'S SPECIFICATION. O (TERMINATE AT 8"(150MM) E.. INSTALL MOISTURE RESISTANT GREEN BOARD ON THESE DRAWINGS AND THE PROJECT MANUAL <br /> ABOVE CEILING) ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> OMILLWORK BLOCKING SPECIFICATION FOR FRENCH CLEATING SYSTEM. 5/8"GYP.WALL BOARD BACKBAR WALL PER PROJECT MANUAL. SOLE PROPERTY OF STARBUCKS <br /> BOXES REFER TO DETAILS. O (FULL WALL HEIGHT) F. ALL DOORS SHALL BE 32"815MM)MINIMUM CLEAR CORPORATION,WHICH IS THE OWNER OF THE <br /> ODIAPER CHANGING 250 LBS 40 112"TO 46 VZ' 32"(810MM)BEHIND STATION OPENING WHEN OPENED TO 90 DEGREE POSITION COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> STATION (113 KG) (1030MM TO 1 IlOMM) UNLESS OTHERWISE NOTED. BE REPRODUCED(IN WHOLE OR IN PART), <br /> SHARED WITH THIRD PARTIES OR USED IN ANY <br /> OUPPER CBE BLOCKING SPECIFICATION FOR CBE METAL SHELVES. G. SEE SHEET A801 FOR EXTERIOR DOOR AND WINDOW MANNER ON OTHER PROJECTS OR <br /> SHELVING REFER TO VENDOR'S SPECIFICATION AND DETAILS. SCHEDULES EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> . <br /> WATER FILTRATION TED BY PRIOR WRITTEN CONSENT OF STARBUCKS <br /> L COORDINATE LOCATION AND EXTENT WITH PENTAIR CORPORATION.THESE DRAWINGS AND <br /> SYSTEM VENDOR H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> ALL ARTWORK, COMPONENTS AND GC TO INSTALL. DESIGN INTENT FOR A PROTOTYPICAL <br /> FIXTURES, GC TO PROVIDE WALL BLOCKING AS REQUIRED FOR <br /> TBD BY STARBUCKS STORE(WHICH IS SUBJECT TO <br /> ACCESSORIES AND ALL ITEMS FOR A COMPLETE AND SECURE I. VERIFY ALL EXISTING DOORS,HARDWARE AND FRAMES <br /> CASEWORK VENDOR INSTALLATION. EXTEND BLOCKING 8"(205MM) MEET STARBUCKS AND/OR CODE REQUIREMENTS. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> FABRICATIONS NOT (VARIES) BEYOND ON EACH SIDE OF EACH ITEM. ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> SHALL HAVE ANY OBLIGATION NOR LIABILITY <br /> OTHERWISE NOTED J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE <br /> THE OTHER(EXCEPT STATED ABOVE)UNTIL A A <br /> APPROVED PLANS FROM THE CITY. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> K. SEE STRUCTURAL FOR KNEE WALL BRACING. <br /> BOTH PARTIES. <br /> L. SEE SHEET A501 FOR BUILDING DETAILS. STARBUCKS TEMPLATE VERSION:12021.10.22 <br /> M. REFER TO SHEET 1104 FOR FLOOR FINISHES, ARCHITECT OF RECORD <br /> GRAPHITE <br /> GENERAL LEGEND GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> 1807 7TH AVENUE,SUITE 700 <br /> SEATTLE,WA 98101 <br /> NEW FULL HEIGHT WALL (206)224-3335 <br /> 0 EXISTING WALL <br /> 4'-2" 3'-2" 2'-4" 5 1/2" 5'-101/4" 4'-3 1/2" 3'-0" 6'-8 1/4" <br /> VIF XX WALL SHEATHING CALL-OUT 9= REGI <br /> 6-6 1/4" <br /> DATUM POINT MARTIN LEE HILL <br /> VIF <br /> STATE OF WASHINCTON <br /> 7 7 <br /> 7 1503 1503 WALL BLOCKING CALL-OUT <br /> 1503 <br /> — — — — SOFFIT ABOVE FOR REFERENCE <br /> OUTLINE OF CASEWORK FOR REFERENCE <br /> � D 10190 04 A A O E D _------- <br /> O 3 g <br /> � I <br /> 3 2-F-N 2-F-N 3•T- T <br /> I <br /> i <8> B Q 2 <br /> L ------------ c B <br /> -- <br /> C $ F B 1 BE3- <br /> o 3 >1 3-T-A Wta N <br /> 2'-2 11T-A S Co <br /> 3-F-N 1 1 3-F-N 3-T-A B ' < QQ Q <br /> C O O C C C B 3 6i <br /> 6 C C 3-F-N "' D 1000 86 OB b I b ZO12'-51/2" 4'-0" ---r----- Q Q <br /> --- ------------------- — — — — — — F ~ <br /> W W <br /> m <br /> LU OW0 0 <br /> O <br /> 0. , W <br /> m5 ----- ----------——_——_�— — — s——_——-- _--_---- — _--_-- arA— STORE#: 22817 <br /> PROJECT#: 60007-039 <br /> O C OK I I C C C ISSUE DATE: 1 012 7/2 0 2 3 <br /> I I <br /> I I DESIGN MANAGER: GRAPHITE <br /> -----_—__ 11 <br /> PRODUCTION DESIGNER: GRAPHITE <br /> 11 <br /> I I <br /> CHECKED BY: GRAPHITE <br /> I I <br /> I I 8'-91/2" 7'-8 i14" <br /> Revision Schedule <br /> I I <br /> 18'-10 1/4" 8'•7 3/4" 14'-8 1/2" I I Rev Date B Description <br /> VIF I I <br /> 3 <br /> I503 <br /> SHEET TITLE: <br /> nFLOOR PLAN BUILDING FLOOR PLAN <br /> N SCALE:AS SHOWN <br /> SHEET NUMBER: <br /> A101 <br />