Laserfiche WebLink
8 7 6 5 4 3 2 1 <br /> EQUIPMENT CONTROL PAC(ECP) REMOTE SENSOR IN CONDITIONED AREA <br /> MOUNTED INSIDE HVAC SYSTEM USE SINGLE SENSOR PER ECP/HVAC SYSTEM GENERAL NOTES <br /> O O PICK SENSOR TYPE BY LOCATION W <br /> 1.SURVEYOR ENERGY MANAGEMENT SYSTEM HARDWARE IS SUPPLIED BY STARBUCKS. <br /> O❑ 0 � o RS410 WALL MOUNT RS420 DROP DOWN <br /> S USE IN FOH ONLY USE IN BOH ONLY 2.DRAWING FOR GENERAL INFORMATION,DESIGN INTENT,AND COORDINATION ONLY. Cn <br /> 3.LOCAL BUILDING CODES TAKE PRECEDENCE OVER THIS DOCUMENT. <br /> D CKS <br /> PHOTOCELL MOUNTED ® ® 9 m 4.NOT ALL WIRING IS SHOWN ON THIS DRAWING.FOR CLARITY,ONLY ONE EXAMPLE D Z ©:0:3 s <br /> OUTDOORS,TYPICALLY ��❑_ ❑�� OF EACH TYPE OF DEVICE IS SHOWN. O TA <br /> RUB I I/ <br /> ON ONE HVAC 2835 N MCCARRAN BLVD#103 <br /> D O V o 0 o u o u V D ••- 5.REFER TO THE SURVEYOR INSTALLATION INSTRUCTIONS FOR EACH COMPONENT <br /> MOTION DETECTORS FOR DETAILED WIRING AND ADDITIONAL CRITICAL INFORMATION. SPARKS,NEVADA 89431 <br /> 1 OR MORE AS NEEDED .4aQ=AQ 0 .�� (775)331-8551 <br /> SURVEYOR (TYPICALLY 2 REQUIRED) 6.CAUTION! INSTALLATION REQUIRES THE REMOVAL OF SAFETY COVERS AND <br /> RS-485 COMM 9 EXPOSE THE INSTALLER TO HIGH VOLTAGE AND ELECTRICAL HAZARDS. U THESE DRAWINGS AND THE PROJECT MANUAL <br /> ECP POWER& CONNECT 5 EQUIPMENT `__— USE OF A LICENSED ELECTRICIAN IS REQUIRED.FOLLOW ALL APPROPRIATE ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> HEALTH SENSORS AND SAFETY PRECAUTIONS.ADDITIONAL SAFETY INFORMATION IS IN THE = SOLE PROPERTY OF STARBUCKS <br /> HVAC CONTROL N CORPORATION,WHICH IS THE OWNER OF THE <br /> O ® O O WIRING 1 REMOTE SENSOR I I SURVEYOR INSTALLATION MANUALS. LL COP RGHTINTHISWORK.REPRODUCED(INWHOLE OR NH PART),T <br /> SURVEYOR L—_ 7.USE WALL MOUNT REMOTE SENSOR IN FRONT OF HOUSE.MOUNT ON INSIDE WALL SHARED WITH THIRD PARTIES OR USED IN ANY <br /> LIGHTING CONTROL BOARD 4 TO 5 FT AFF.AVOID AREAS WITH DIRECT AIRFLOW FROM SUPPLY REGISTERS. MANNER ON OTHER PROJECTS OR <br /> RS-485 COMM THERMOSTAT COMMUNICATION 'A PRIOR WRITTEN CONSENTOF STARBUCKS <br /> EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> w <br /> AND POWER WIRING 8.USE A DROP DOWN REMOTE SENSOR IN BACK OF HOUSE.THE SENSOR CLIPS TO <br /> CORPORATION.THESE DRAWINGS AND <br /> THE T-BAR GRID AND ADJUSTED SO THE BOTTOM OF THE SENSOR IS 8 TO 9 FT AFF. Z SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> ALLOW 2 FT OF CLEARANCE FROM METRO SHELVING AND AVOID AREAS WITH DIRECT DESIGN INTENT FOR A PROTOTYPICAL <br /> AIRFLOW FROM SUPPLY REGISTERS. O STARBUCKS STORE(WHICH IS SUBJECT TO <br /> SURVEYOR CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> LIGHTING CONTROL PANEL BUILT IN CONTACTORS ® THERMOSTAT TERMINAL- 9.FOR SURVEYOR EMS TECHNICAL SUPPORT AND SYSTEM COMMISSIONING,PLEASE ♦ ACTUAL SITE YO OBLIGATION <br /> NEITHER PARK <br /> V SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> CONNECT TO LIGHTING CIRCUITS PER ZONES ON ELECTRICAL PLANS THERMOSTATS GROUPED IN CONTACT SURVEYOR TECHNICAL SUPPORT,(855)647-7660,OPTION 1 OR EMAIL THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> C I N—————————————i ® MANAGERS WORKSTATION AREA NCSSC.VENSTAR@SYLVANIA.COM.HOURS 6:OOAM TO 8:OOPM PACIFIC,MON-FRI. C WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> BOTH PARTIES. <br /> O O O STARBUCKS TEMPLATE VERSION:023.04.24 <br /> 1. <br /> o 0 0 UL ARCHITECT OF RECORD. . a <br /> C-1 C-2 C-3 C-3A C-4 C-4A NOTES: <br /> INTERIOR INTERIOR EXTERIOR EXTERIOR PARKING PARKING <br /> WORK SALES_ SIGN SIGN _SITE_ SITE J 1.OUTDOOR TEMPERATURE SENSOR CONNECTED TO ONE ECP ONLY PER LOCATION. SURVEYOR EMS COMPONENTS <br /> FACE NORTH WHEN POSSIBLE. VENSTAR PART SBUX ITEM# DESCRIPTION QUANTITY W <br /> 2.SEE GENERAL NOTES 7 AND 8 FOR REMOTE SENSOR MOUNTING LOCATION DETAILS. LCP401 011029483 LIGHTING CONTROL PANEL 1 GRAPHITE DESIGN CROUP,LLc,ARCHITECTS <br /> DC400 011029485 DATA CONCENTRATOR 1 0 1807 7TH AVENUE,SUITE 700 <br /> OTS400 011029487 OUTDOOR TEMPERATURE SENSOR 1 SEATTLE,WA 98101 <br /> LIGHTING CONTROL HVAC CONTROLS Z (206)224-3335 <br /> ECP400 011029489 EQUIPMENT CONTROL PAC 1 PER HVAC <br /> CT414 011029490 COMMUNICATING THERMOSTAT 1 PER HVAC W <br /> DATA CONCENTRATOR SP400 011029491 SENSOR PAC 1 PER HVAC ROY SC <br /> DATA CONCENTRATOR ----IRS410 011029492 WALL MOUNT REMOTE SENSOR 1 PER FOH HVAC ~ �O� <br /> O ECP THERMOSTAT RS420 011050767 NARROW DROP DOWN SENSOR 1 PER BOH HVAC Z <br /> O ® MD400 011029497 ADDITIONAL MOTION DETECTOR AS NEEDED y <br /> o O O 6 FIRST HVAC SYSTEM. a, <br /> Re t <br /> g ETHERNET FOH STYLE SENSOR SHOWN, B <br /> O o TO NETWORK SEE GENERAL NOTES 7 AND 8 FOR O ONNL aura ro/zs/zi <br /> 0 o SENSOR MOUNTING LOCATION. con pzsas <br /> REMOTE <br /> SENSOR] Z <br /> CO SECOND HVAC SYSTEM. <br /> SURVEYOR o ECP THERMOSTAT REPEAT AS NECESSARY, <br /> BOH STYLE SENSOR SHOWN. <br /> ee o o e , r-18 SEE GENERAL NOTES 7 AND 8 FOR }, <br /> SENSOR MOUNTING LOCATION. J r <br /> DATA CONCENTRATOR MULTIPLE ECP'S MAY BE Z �— <br /> POWER SUPPLY CONNECT ETHERNET CABLE TO LAN REMOTE COMBINED ON ASINGLE <br /> SURVEYOR RS-485 COMM PORT#6 ON ROUTER IN DATA RACK SENSOR I D PORT <br /> WHEN MORE THAN O 0) <br /> HOME-RUN WHEN POSSIBLE CD CONNECT TO ALL DEVICEL J 0 Q <br /> o ®Q�T_Tj� LIGHTING CONTROL PANEL ~ } Q <br /> O C0 <br /> O <br /> ®® MOTION SENSORS Z w <br /> a,...�.,_... 1 OR MORE AS W w w m <br /> A NECESSARY A C Q Q w <br /> CAT-5 ETHERNET p VENSTAR INC. C z ¢ Z <br /> CABLE CONNECTED a U F_ Ill <br /> TO NETWORK ROUTER. w O w <br /> LE <br /> PHOTOCELL SURVEYOR o a W a o <br /> STARBUCKS FULL LIGHTING AND HVAC CONTROLS <br /> slzE 'Al <br /> ATE ow REv W STORE* 22$17 <br /> -039 <br /> DATA CONCENTRATOR BASIC LOW VOLTAGE WIRE RUNS AINIIDLAWINGTI0N5 ��y2/,5 D 1-29-15 s1s-DIN B PROJECT#: 100073 <br /> A INITIAL DRAWING RELEASE cc zntns scALE NONE C.GODWIN tOF1 ISSUE DATE: 10.2.2023 <br /> W DESIGN MANAGER: GRAPHITE <br /> 8 7 6 5 4 3 2 1 Q PRODUCTION DESIGNER: GRAPHITE <br /> CHECKED BY: <br /> Z Revision Schedule <br /> FOR REFERENCE ONLY <br /> Date By Description <br /> N <br /> W <br /> V EET TITLE: <br /> � VENSTAR CONTROL <br /> DIAGRAMS <br /> SCALE:AS SHOWN <br /> SHEET NUMBER: <br /> E 104 <br />