ELECTRICAL GENERAL NOTES <br /> LUMINAIRE SCHEDULE <br /> A.ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON <br /> LAMP LAMP SELECTED INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. <br /> MARK MANUFACTURER CATALOG NUMBER VOLTAGE WATTS MOUNTING DESCRIPTION TYPE BY OTHERS? REMARKS ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE <br /> OWNER. <br /> 11154 LITHONIA LIGHTING 2BLT2 2X2BLT-33L—ADP—LP830 120 277 27 W WALL, SURFACE INTEGRAL LED YES COORDINATE ORDERING WITH ARCHITECT. B.VISIT THE PROJECT SITE,REVIEW EXISTING CONDITIONS AGAINST THE CONTRACT W <br /> 11427 JUNO R552WH 120 75 W TRACK 75W PAR30 LED YES WHITE TRACK HEAD DOCUMENTS,AND BECOME FAMILIAR WITH THE WORK PRIOR TO BIDDING AND START <br /> 12946 JUNO TRACK SECTION: R4BL JOINER: R38BL MINI END FEED: RCLFM118L 120 — TRACK — YES 4' BLACK TRACK SECTION NTH JOINER AND MINI END FEED OF WORK.SIGNING THE CONTRACT IS AN ACKNOWLEDGMENT THATTHE SITE VISIT <br /> 15057 LITHONIA 2BLT4-40L—ADP—EZ1—LP830 120 34 W CEILING, RECESSED INTEGRAL LED YES 2X4 LOW—PROFILE RECESSED LUMINAIRE— 0-10V DIMMABLE HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED. <br /> 15057EM LITHONIA 2BLT4-40L—ADP—EZ1—LP830—E10WLCP 120 34 W CEILING, RECESSED INTEGRAL LED YES 90 MINUTE BATTERY BACKUP C.DEMOLISH ANY EXISTING EQUIPMENT,DEVICES,AND LUMINAIRES AS INDICATED <br /> AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE <br /> 20683 FEISS KP1001 MBK 120 5 W I CEILING, SUSPENDED G9 T4 5W LEDs LED I YES NEW WORK.REMOVE ALL EQUIPMENT,DEVICES,LUMINAIRES,CONDUITS, <br /> 20748 DOLAN HOSPITALITY ZVL47321—CH-2700K 120 17 W WALL, SURFACE INTEGRAL LED YES SUPPORTS,HANGERS,ETC.THAT ARE NOT SHOWN AND ARE REQUIRED TO BE ©2023 S—BUCKS-EmMP,wr <br /> 21772 ALPHABET NUS-RA-SW-I3LM-27K-90—S35-120—DIMiO—NC—WH—WH 120 12 W CEILING, RECESSED INTEGRAL LED YES REMOVED IN ORDER TO COMPLETE THE NEW WORK. S TA R B U C K <br /> 21772EM ALPHABET NU3—RA—SW—I3LM-27K-90—S35-120—DIM10—NC—WH—WH—EM12 120 12-W CEILING, RECESSED INTEGRAL LED YES D.ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR <br /> 21774 ALPHABET NU3—RA—SW—I01_M-27K-90—D60— 120—DIMI O—NC—WH—WH 120 9 W CEILING, RECESSED INTEGRAL LED YES ENTIRETY.CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED O 2835 N MCCARRAN BLVD#103 <br /> 22215 CS ILLUMINATION LL91STP—MO-27K—SL—SL 24 4W FT WALL,CEIUNG,SURFACE INTEGRAL LED YES TO THE SOURCE OVERCURRENT DEVICE.RACEWAYS WHICH ARE INSTALLED IN OR — SPARKS,NEVADA 89431 <br /> 22249 ALPHABET NU3—RD—SW—i3LM-3GK-90—HE50—UNV—DIM10—NC—WH—WH 120 12 W CEILING, RECESSED INTEGRAL LED YES BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED,BUT ALL OVERHEAD OR (775)331-8551 <br /> 22249EM ALPHABET NU3-RD-SW-I3LM-30K-90-HE50-UNV-DIM70-NC-WH-WH-EM12 EXPOSED RACEWAYS SHALL BE REMOVED.EXPOSED RACEWAYS TO BE <br /> 120 12 W CEILING, RECESSED INTEGRAL LED YES 90 MINUTES AT 12W BATTERY BACKUP ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2' '+ <br /> X2305 SCHOOLHOUSE ELEC. JANNETTE SCONCE 1 120 200 W WALL, SURFACE G25 MEDIUM BASE LED YES COORDINATE FINISH WITH ARCHITECT INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. V THESE DRAWINGS AND THE PROJECT MANUAL <br /> ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> LUMINAIRE SCHEDULE GENERAL NOTES: <br /> E.MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER = SOLE PROPERTY OF STARBUCKS <br /> TO REMAINING EQUIPMENT,DEVICES AND LUMINAIRE THAT ARE NOT BEING CORPORATION,WHICH IS THE OWNER OF THE <br /> A. LUMINAIRE SYMBOLS THAT ARE LABELED "EM" ON THE PLAN(S) INDICATE LUMINAIRES THAT SERVE AS EMERGENCY LIGHTING. PROVIDE EMERGENCY ILLUMINATION FOR A MINIMUM OF 90 MINUTES. REMOVED. IV COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> B. ANY PROPOSED SUBSTITUTIONS FOR LUMINAIRES THAT ARE SELECTED BY OTHERS REQUIRE THE APPROVAL OF THE SPECIFYING ENTITY. IL BE REPRODUCED(IN WHOLE OR IN PART), <br /> F.WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING BE <br /> WITH THIRD PARTIES OR USED IN ANY <br /> DESIGN,ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN laaa MANNER ON OTHER PROJECTS OR <br /> CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS.COORDINATE N PRIOR WRITTEN CONSENT OF STARBUCKS <br /> PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR CORPORATION.THESE DRAWINGS AND <br /> ELECTRICAL PLAN NOTES <br /> THAT ARE MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND Z SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> SWITCHBANK TSB" SCHEDULE ❑ PROVIDE LIGHTING CONTROL SWITCHBANK.SEE SWITCHBANK SCHEDULE FOR ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. DESIGN INTENT FOR A PROTOTYPICAL <br /> SNITCH TAG ZONE DESCRIPTION CONTROL TYPE ADDITIONAL INFORMATION.LOWERCASE LETTERS ADJACENT TO THE LUMINAIRES O STARBUCKS STORE(WHICH ISSUBJECTTO <br /> ON PLANS CORRESPOND TO THE ASSOCIATED SWITCH ON THE SWITCHBANK G.SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> ° WORKROOM LIGHTS 3—WAY TOGGLE SWITCH THROUGH CONTACTORS OR RELAYS FOR CONTROL. <br /> b ENGINE LIGHTS LINE VOLTAGE DIMMER SCHEDULE.CONFIRM SWITCHBANK WILL FIT WITHIN THIS DESIGNATED AREA AND ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> c CAFE DOWNUGHTS LINE VOLTAGE DIMMER STACK MULTIPLE SWITCHBANKS,WITH FEWER GANGS,AT THIS LOCATION IF A H.PRESERVE THE FIRE RATING OF ANY FIRE-RATED CEILING ASSEMBLIES BY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> SINGLE SWITCHBANK WILL NOT FIT WITHIN THIS DESIGNATED AREA. PROVIDING THE APPROPRIATE FIRE-RATED LUMINAIRE TENTS AS MANUFACTURED THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> d CAFE ACCENT LIGHTS SPST TOGGLE SWITCH BY TENANT OR NELSON FIRESTOP OR BY BUILDING FIRE-RATED ENCLOSURES WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> e RESTROOM VESTIBULE UGHTS LINE VOLTAGE DIMMER �2 INSTALL THIS LUMINAIRES REMOTE LOW VOLTAGE LIGHTING POWER SUPPLY! AROUND EACH LUMINAIRE THAT IS RECESSED INTO THE FIRE-RATED ASSEMBLY. BOTH PARTIES. <br /> TRANSFORMER(RPS)IN AN INCONSPICUOUS,ACCESSIBLE LOCATION AND Li <br /> GENERAL NOTES: PROVIDE FINAL CONNECTION TO LUMINAIRE.COORDINATE MOUNTING LOCATION COORDINATE FIRE-RATED CEILING ASSEMBLY LOCATIONS WITH THE <br /> A. PROVIDE BOX PARTITIONS BETWEEN CONTROLS OF DIFFERING VOLTAGES. <br /> OF RPS WITH OWNER PRIOR TO ROUGH-IN.THE LENGTH OF CONDUCTORS ARCHITECTURAL DRAWINGS, O STARBUCKS TEMPLATE VERSION:023.04.24 <br /> BETWEEN RPS AND ASSOCIATED LUMINAIRE SHALL NOTE EXCEED I. ALL LUGS,TERMINALS,ETC.IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE <br /> MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM CONDUCTOR LENGTH,RPS LISTED FOR A MINIMUM OF 75 DEGREE C CONDITIONS.TERMINATIONS LISTED FOR LL ARCHITECT OF RECORD <br /> DESIGNATIONS INDICATED ADJACENT TO LUMINAIRES CORRESPOND TO THE ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED. <br /> ASSOCIATED RPS SUPPLYING THE LUMINAIRE. J. CIRCUITS SERVING EMERGENCY LIGHTING EQUIPMENT SUCH AS EMERGENCY <br /> 3� COVE LIGHT LOCATED UNDER COUNTER. BATTERIES SHALL NOT SHARE A NEUTRAL(SHALL NOT BE PART OF A MULTIWIRE <br /> BRANCH CIRCUIT)WITH ANY OTHER CIRCUIT.PROVIDE A SEPARATE NEUTRAL FOR <br /> EVERY CIRCUIT THAT SERVES EMERGENCY LIGHTING. W <br /> K.ALTHOUGH NOT SPECIFICALLY SHOWN,THE ELECTRICAL CONTRACTOR SHALL GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> PROVIDE ALL REQUIRED LOW VOLTAGE WIRING AND DATA CABLING,INCLUDING Q 1807 7TH AVENUE,SUITE 700 <br /> ALL 0-10V CONTROL WIRING WHERE APPLICABLE,PER THE MANUFACTURER'S SEATTLE,WA 98101 <br /> RECOMMENDATIONS,FOR A COMPLETE,FUNCTIONAL LIGHTING CONTROL Z (208)224-3335 <br /> SYSTEM, <br /> L.LUMINAIRES MARKED"EX'ARE EXISTING LUMINAIRES THAT ARETO REMAIN IN W <br /> PLACE.ALL EXISTING LUMINAIRES WITHIN THE LIMITS OF CONSTRUCTION SHALL <br /> Y <br /> BE REPAIRED TO A LIKE-NEW CONDITION,THOROUGHLY CLEANED,AND �y RO SCy <br /> RELAMPED.ANY EXISTING LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR <br /> SHALL BE REPLACED WITH AN IDENTICAL LUMINAIRE. Z <br /> M.LUMINAIRES MARKED"RR"ARE EXISTING LUMINAIRES THAT ARE TO BE OR HAVE <br /> !;,°M,�"'•� BEEN RELOCATED.ALL LUMINAIRES DESIGNATED FOR RELOCATION SHALL BE st <br /> DISCONNECTED FROM EXISTING BRANCH CIRCUIT,REMOVED FROM EXISTING <br /> AREA,STORED,REPAIRED TO A LIKE-NEW CONDITION,INSTALLED IN REMODELED <br /> AREA,RECONNECTED,THOROUGHLY CLEANED,AND RELAMPED.ANY RELOCATED ONAL t7oh�o/aaiv <br /> LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN O ca.�02609 <br /> EX 3 <br /> IDENTICAL LUMINAIRE. <br /> EX EM 3c EX EX Z <br /> 30e 3c <br /> Oe <br /> EX � <br /> 11154 L 22249EM L 22249(6) 3d 3c 3c 3d \ <br /> --————— — L12948 <br /> 0 Ex L X2305(2) t Ex EX <br /> 1° EX (2)L A1427 <br /> L 20748 30s a 3c L 21774(4) (4)L 21774 3c 2 N <br /> r <br /> f (")f� Z Q 00 <br /> 0 O Q 0) <br /> L 15057 M <br /> 3c 3c 3c 3c 3c <br /> EXIS77NG PANEL 'H" 7_71 ST571M 3c EM 11 <br /> RR 06 <br /> _ L 22249EM L 22249(5) O <br /> 3c3° RRLX3c16 1b 1 ib 1 1b 1b 1b 1b tb 16 RR RR W3d / , � WEXE E I 1 I 1° 1c PSOS3d 3d 3d L1i Qui <br /> PS0 3d 0 o L 20883(3) 60W L 22215 3 1jc ii C E] �J <br /> — _ 0 3d O e Z 4 L <br /> L1 057E 15057(8) d tb 1b 05 W O W O LU <br /> - -------- -- t2b- 2eM ----- ---- - - - - - 'b- - - - 0 �M CD <br /> 2 1b b lb lb 1b 1b 1b EM b ib 1b 1b 1b ib 16 / J 0. W n, r <br /> 2 98W L 22215 �/ <br /> PS01 —— — PSO W STORE#: 60007 <br /> _3a_____ _ _ ___ ___3a__ � ' PROJECT#: 60007-039 <br /> F., EM 2 BOW u \g6W 77A EX EX ISSUE DATE: 10.2.2023 <br /> L 22215 L 22215 W DESIGN MANAGER: GRAPHITE <br /> _Jd PS03 PSO 3d L 22215 / PRODUCTION DESIGNER: GRAPHITE <br /> ___ —_ _____ __________3d____ / Q <br /> — CHECKED BY: <br /> ib 1b <br /> Z Revision Schedule <br /> Gabe I B Deserl tlon <br /> L 21772(2) _ <br /> N <br /> W <br /> SHEET TITLE: <br /> G LIGHTING PLAN <br /> LEGEND SCALE:AS SHOWN <br /> nLIGHTING PLAN EXIS771VG x SHEET NUMBER: <br /> 1111� <br /> I V —NEW WORK .7L���IC0. � <br /> RC' <br /> h ® NEW 70 EX/SANG COIVNEC77ON E 103 <br />