1010 N BROADWAY 2024 STARBUCKS Plans 2025-07-02
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
Plans
>
1010 N BROADWAY 2024 STARBUCKS Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 7:02:53 AM
Creation date
6/16/2025 8:50:56 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Permit
B2311-026
Year
2024
Notes
TI EXISTING STARBUCKS CAFE, PARTITIONS, EQUIPT RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING PANEL "B" EXISTING PANEL "A" <br /> FED FROM: PANEL"A" MOUNTING: FLUSH MOUNTED FED FROM: UTILITY TRANSFORMER MOUNTING: FLUSH MOUNTED <br /> VOLTAGE: 208Y/120V.3 PHASE,4 WIRE ENCLOSURE: NEMA 1 VOLTAGE: 208Y/720V,3 PHASE,4 WIRE ENCLOSURE: NEMA i <br /> BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING <br /> BUS LOAD: 115 AMPS AIC/SCCR RATING: MATCH EXISTING BUS LOAD: 342 AMPS AIC/SCCR RATING: MATCH EXISTING A W <br /> BUS RATING: 400 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR BUS RATING: 400 AMPS OPTIONS-: BONDED EQUIPMENT GROUND BAR <br /> MIN: MAIN LUG ONLY MAIN: 400/3 MAIN BREAKER <br /> LOAD(VA) LOAD(VA) LOAD(VA) LOAD(VA) <br /> NOTES CKT.1 LOAD DESCRIPTION A B C BREAKER BREAKER A 1 B C LOAD DESCRIPTION CKT. NOTES NOTES CKT. LOAD DESCRIPTION A B I C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES <br /> C-1 1 WORKROOMI U.. 1643 20/1 20/1 300 EXTERIOR SIGNS 2 C-3 1 RN-1 7176 70/3 20/2 1144 ICE MAKER,HEAD 2 GFCI lie <br /> C-2 3 CAFE UGHTS 250 20/1 20/1 200 MENU BOARD 4 C-3 3 ----- 7176 --- --- 1144 ---- 4 ©zozs sTnaeucXS CAFFEE WNFANY <br /> 5 SPARE 20/1 20/1 200 DT SIGNS 6 C-3 5 ----- 7176 --- 20/1 460 UC REFRIGE. 5 GFCI Z <br /> 7 SPARE 20/2 40/3 2333 WATER HEATER 8 7 RN-Z 7176 70/3 20/1 1500 INSTAHOT B GFCI S T A R B U C K S' <br /> 9 ----- --- --- 2333 ----- 10 9 ----- 7176 --- 20/1 460 UC REFRIGE. 10 GFCI <br /> HPL n FOOD CASE 800 20/2 --- 2333 ----- 12 11 ----- 7n6 --- 20/1 1500 INSTAHOT 12 GFCI 2835 N MCCARRAN BLVD#103 <br /> 13 ----- 800 --- 20/1 200 BUILDING LIGHTS 14 C-3 GFCI 13 WATER FlWNG STATION 1300 20/1 20/1 540 SEATING RECEPTS 14 SPARKS,NEVADA 89431 <br /> GFCI 15 DIGITAL MENU BOARD 360 20/1 20/2 SPARE 16 GFCI 15 WATER FlWNG STATIGIJ 180 20/1 20/1 SPARE 16 (� (775)331-8551 <br /> GFCI 17 REACH-IN REFRIG. 1000 20/1 --- ----- 18 GFCI 77 ESPRESSO 2975 40/2 20/1 100 RAIN BIRD 18 <br /> GFCI 19 REACH-IN REFRIG. 1000 20/1 20/2 400 POLE LIGHTS 20 C-4 19 ----- 2975 --- 20/1 100 SPEAKER POST 20 THESE DRAWINGS AND THE PROJECT MANUAL <br /> GFCI 21 MANAGER'S DESK 720 20/1 --- 400 ----- 22 GFCI 21 ESPRESSO 2975 40/2 20/1 1500 RR HANG DRYER 22 HPL ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> SOLE PROPERTY OF STARBUCKS <br /> GFCI 23 MANAGER'S DESK 960 20/1 20/1 100 UGH'ING CONTROL PANEL 24 23 ----- N2O/1 <br /> 20/1 900 IT RACK 24 GFCI CORPORATION,WHICH IS THE OWNER OF THE <br /> GFCI 25 MI DISPENSER 1500 20/1 20/1 1000 REACH-IN REFRIGE, 26 GFCI 25 ROOF RECEPT. 360I 15/1 568 RECIRC.PUMP,P-1 26 C-1 /V COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> GFCI 27 GRINDER 1800 20/1 20/1 1000 REACH-IN REFRIGE. 28 27 DUCT SMOKE DETECTOR 1 20/1 180 ICE MAKER,gVERTER 28 GFCI LL BE REPRODUCED(IN WHOLE OR IN PART), <br /> GFCI 29 UC REFRIGE. 460 20/1 20/1 90 RR AND VEST18.EM LIGHTS 30 GFCl/C-1 GFCI 29 PARTNER AREA MICROWAVE 1 20/1 480 UC REFRIGE 30 GFCI L SHARED WITH THIRD PARTIES OR USED IN ANY <br /> r MANNER ON OTHER PROJECTS OR <br /> GFCI 31 OVEN 3000 30/2 20/1 72C DT POS 32 GFCI GFCI 31 DT WINDOW 3001 20/1 SPARE 32 EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 33 ----- 3000 --- 20/1 SPARE 34 GFCI GFG 33 NITRO DISPENSER 1 30/2 2984 WARMING WALL 34 GFCI V/ PRIOR WRITTEN CONSENT OF STARBUCKS <br /> GFG 35 OVEN 3000 30/2 20/1 720 DT POS 36 GFCI GFCI 35 NITRO GENERATOR --- 2984 36 CORPORATION.THESE DRAWINGS AND <br /> 37 ----- 3000 --- 20/1 640 DT UC REFRIGE. 38 GFCI GFCI 37 REACH-IN F1iEEIDt B80 30/3 2831 COLIBI-OVEN 38 GFCI SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> DESIGN INTENT FOR A PROTOTYPICAL <br /> HPL 41 SANITIZER 3120 40/2 50/2 4160 BREWER 40 GFCI GFCI 39 POS --- 2831 40 STARBUCKS STORE(WHICH ISSUBJECTTO <br /> _—__41 ----- 3120 --- --- 4160 ----- a2 41 SPARE --- 2831 ---- 42 CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> FEED-THROUGH LUGS ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> UOTES: 13761 17FTL SUBFEED PANEL'B' SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE 12978 FTL THE OTHER(EXCEPT STATED ABOVE)UNTIL <br /> GFCI PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> HPL PROVIDE PERMANENTLY-INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. VZOXIIIIIA 12627 FTL ------ BOTH PARTIES. <br /> C-1y ROUTE CIRCUIT THROUGH CONTACTOR(/)=CONTACTOR DESIGNATION). r,r <br /> NOTES: C) STARBUCKS TEMPLATE VERSION:i2023.04.24 <br /> SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE <br /> LOAD ANALYSIS FOR PANEL "B" INCLUDING SUBFEED$ GFCI PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. <br /> HPL PROVIDE PERMANENTLY-INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. U. ARCHITECT OF RECORD <br /> DEMAND PHASE A(VA) PHASE B(VA) PHASE C(VA) TOTAL(VA) C-$ ROUTE CIRCUIT THROUGH CONTACTOR(#=CONTACTOR DESIGNATION). <br /> LOAD DESCRIPTION FACTOR CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND ICONNECT.11 EMAND <br /> LIGHTING: 125% 2543 3179 850 1063 290 363 3683 4604 Q ow,.mnrm.,.,aswn,nw.,,m,mmnw:cae,.rmvy� <br /> RECEPTACLE: 100% 1360 1360 1080 1080 1680 1680 4120 4120 LOAD ANALYSIS FOR PANEL "A" (INCLUDING SUBFEEDS) W <br /> OTHER NONCONTINUOUS: 100% 0 0 0 0 100 100 100 100 DEMAND PHASE A(VA) PHASE B(VA) PHASE C(VA) TOTAL(VA) GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> WATER HEATING: 100% 2334 2334 2334 2334 2334 2334 7000 7000 LOAD DESCRIPTION FACTOR CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND CONNECT. DEMAND Q 18077TN AVENUE,SUITE 700 <br /> KITCHEN: 65% 10600 6890 13080 8502 12540 8151 36220 23543 LIGHTING: 125% 2543 3179 850 1063 290 363 3683 4604 S 07p7TH AVENUE, <br /> ATTLE,WA 01 <br /> TOTAL 16836 13762 17344 12978 15944 12627 51123 39367 RECEPTACLE: 100% 2250 2260 2440 2440 4700 4700 9400 9400 Z (206)224-3335 <br /> EQUIVALENT AMPS: 141 115 145 109 142 106 142 110 OTHER NONCONTINUOUS: 100% 400 400 1600 1600 20D 200 2200 2200 i� <br /> PHASE BALANCE: 4.87% -1.10% -3.77% WATER HEATING: 100% 2334 2334 2334 2334 2334 2334 7000 7000 W <br /> KITCHEN: 65% 21010 13657 24214 15740 26525 17242 71749 46637 ROY SC COOLING ONLY: 100% 14352 14352 14352 14352 14352 14352 43056 43056 <br /> MOTOR: 100% 568 568 0 0 0 0 568 <br /> ADD 25%OF LARGEST MOTOR: 100% 1794 1794 1794 1794 1794 1794 5382 5382 Z y <br /> TOTAL: 45260 38542 47554 39321 50195 40984 143038 118846 <br /> EQUIVALENT AMPS: 379 322 397 328 419 342 398 330 31 <br /> PHASE BALANCE: -2.71% -0.74% 3.45% L <br /> F <br /> ONAL <br /> 0 CO aCo m/zs/zT <br /> fT609 <br /> Z <br /> 1 <br /> 0 <br /> Z O Q CIO <br /> C) C <br /> PAD MOUNT TRANSFORMER <br /> I- °� Q <br /> B' LOCAL UTILITY COMPANY } <br /> Z O <br /> TRANSFORMER PAD Q U) 1- <br /> BY ELECTRICAL <br /> CONTRACTOR W LU <br /> Of W W <br /> PRIMARY CONDUIT 0 L.L <br /> BY ELECTRICAL Z Q 7 <br /> CONTRACTOR F-LU O U LO <br /> Uj <br /> PRIMARY FEEDERS BY EXISTING 2 SETS OF O O O <br /> LOCAL UTILITY COMPANY 4-250 KCMIL, LL O <br /> WITH GROUND CL MM Q-' <br /> EACH SET J D- I.o d r <br /> 114"x 4"x 12"COPPER GROUND IN 2 1/2-CONDUIT <br /> BAR WITH WALL MOUNRNC <br /> 22817 <br /> BRACKETS AND INSULATORS W STORE* 60007 <br /> ` PROJECT#: 60007-039 <br /> 0 LUG AS REQUIRED FOR CTs M / ISSUE DATE. 10.2.2023 <br /> EOUIPMEN7 RACKS <br /> LUG AS REQUIRED G ® L_ _J W DESIGN MANAGER: GRAPHITE <br /> FOR CABLE 77?AY <br /> PRODUCTION DESIGNER: GRAPHITE <br /> o EXISTING 2 SETS OF <br /> 0 0 4-250 KCMIL, CHECKED BY: <br /> � G WITH GROUND <br /> EACH SET <br /> \ O 0 O O O IN 21/2"CONDUIT Z Revision Schedule <br /> 0AWG EQUIPMENT � Date By Description <br /> 0 GROUNDING CONDUCTOR TO <br /> 0'-,0 MAIN BUILDING GROUNDING LEGEND <br /> ELECTRODE SYSTEM PANEL PANEL <br /> l� „A., I <br /> EXISTING EXISTING EX1577NG Y! <br /> FTL <br /> —NEW WORK <br /> SAL M71E5 AA'A'JGAE 70 7NJS LIEIAIL• <br /> ® NEW TO EXIS771VG CONNECTI Uj SHEET TITLE: <br /> A. MOT ALL PARTS AAD PART MUEERS ARE 90VV IN TFE DETAIL. TfE ELEG7RICAC G PANEL SCHEDULES AND <br /> w CONTRACTOR IS RESPONSIBLE FOR A CCK/PLETE ACTWORKIAG IAlSTALLATION, INCLLDINL <br /> MISCFILAAEOUS APN.RTENANCES REcwrRED Bur ACT��. ONE-LINE DIAGRAM <br /> SCALE:AS SHOWN <br /> r,-N GROUND BAR DETAIL EXISTING ONE-LINE DIAGRAM-SHOWN FOR REFERENCE ONLY <br /> v NOTTO SCALE `1J NO7705CALE C�L.�..ftl SHEET NUMBER: <br /> a .7�1��IC�1{ E601 <br />