Nor- <br /> BLUE��N RAVEN <br /> UL CODE COMPLIANCE NOTESZ 0 SOLAR <br /> on SFM FRAME <br /> ME MICRORAIL TM INSTALLATION GUIDE ; PAGE <br /> ________________________________________________________________________________________________ <br /> SYSTEM LEVEL FIRE CLASSIFICATION <br /> The system fire class rating requires installation in the m amner specified in the perform ance is inherent in the SFM design,and no additional m Ligation m (Bsures <br /> SUNFRAM EM CRORAIL (SFM )Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no <br /> the system level fire portion of UL 1703. This UL 1703 classification has been required m him u mor m acim u mheight Lim Cation above the roof deck to m antain <br /> incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM .SUNFRAM EM CRORAILT"com ponents shall <br /> B & C system level perform aice for low slope & steep sloped roofs when used be m canted over a fire resistant roof covering rated for the application. <br /> in conjunction with type 1 and type 2 m odules. Class A, B & C system level fire <br /> Module Type R I oof Slope S i ystem Level Fire Raking M crorail Directiom M dule Orientation M tigation Required <br /> Type 1 and Type 2 S teep Slope & Low Slope C lass A, B & C E ast-W Est L andscape OR Portrait N one Required <br /> UL2703 TEST M CDULES <br /> See pages 22 and 23 for a list of m odules that were electrically and m a:hanically tested or <br /> qualified with the SUNFRAM EM ICRORAIL (SFM )com ponents outlined within this Installation Guide. <br /> • M a(im u mArea of M odule = 27.76 sqft <br /> • UL2703 Design Load Ratings: <br /> a) D ownward Pressure - 113 PSF / 5400 Pa <br /> b) U pward Pressure - 50 PSF / 2400 Pa <br /> c) D own-Slope Load - 21.6 PSF / 1034 Pa <br /> • Tested Loads: <br /> a) D ownward Pressure - 170 PSF / 8000 Pa <br /> b) U pward Pressure - 75 PSF / 3500 Pa <br /> c) D own-Slope Load - 32.4 PSF / 1550 Pa <br /> • M a(im u mSpan = 6ft <br /> • Use with a m a<im u mover current protection device OCPD of 30A <br /> • System conform sto UL Std 2703, certified to LTR AE-001-2012 <br /> • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span <br /> • P V m odules m air have a reduced load rating, independent of the SFM load rating. Please consult <br /> the PV m odule m anufacturer's installation guide for m are inform anon <br /> • D own-Slope design load rating of 30 PSF/ 1400 Pa for m odule areas of 22.3 sq ft or less <br /> DRAWING NUMBER: <br /> SS <br />