Laserfiche WebLink
ABBREVIATIONS HVAC PIPING IDENTIFICATION DUCTWORK ACCESSORIES GRILLE/REGISTER/DIIFFUSEHIIAC PROJECT SPECIFIC PROJECT IR SHEENJ NECHAIMCALMEX I���r� <br /> GENERAL ETNANE <br /> M001 MECRe*WALIEGE�,MAP,B.O.D.&ABBREVIA'n M <br /> AD ACCESS DOOR AC AIR CONDITIONING - - - - - - - - - - RETURN PIPING m-w SCHEDULE AMSPECUgCA710N <br /> SUPPLY GRILLE ��// <br /> AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT SUPPLY PIPING � CEILING SUPPLY AIR DIFFUSER M121 IDEC7WNCALFIIJORPLANANDROOF PLAN i /C Your Building <br /> AFC ABOVE FINISHED GRADE S-001 STRLCJIURALDECAR, <br /> BDD BACKDRAFT DAMPER MGKINSTRY Co,LLC <br /> BHP BRAKE HORSEPOWER BOD BOTTOM OF DUCT "" RETURN OR EXHAUST GRILLE <br /> BOP BOTTOM OF PIPE Z CEILING RETURN GRILLE <br /> BOOT BOTTOM CC COOLING COIL PIPING FITTINGS <br /> OR TRANSFER AIR GRILLE <br /> CRU COMPUTER ROOM UNIT <br /> CIL CENTERLINE CT COOLING TOWER .- TEE UP VOLUME DAMPER SEATTLE: <br /> CLG CEILING CV CONSTANT VOLUME _ — TEE DOWN 5005 3RD AVENUE S <br /> CFM CUBIC FEET PER MINUTE CEILING EXHAUST GRILLE PO BOX 24567 <br /> CO CARBON MONOXIDE DB DUCT BOARD TEE ON W/ELBOW MOTOR OPERATED DAMPER <br /> CO2 CARBON DIOXIDE DIFF DIFFUSER O TEE UP W/ELBOW SEATTLE,WA 98124 <br /> CSR CURRENT SENSING RELAY DMPR DAMPER 1-800-669-6223 <br /> 90°ELBOW UP N � LINEAR DIFFUSER(CEILING) <br /> DISCH DISCHARGE EA EXHAUSTAIR 7 90°ELBOW DN <br /> ON DOWN EAT ENTERING TEMPERATURE 0 LINEAR DIFFUSER(WALL) www.mckinstry.com <br /> DS DISCONNECT SWITCH;DOOR SWITCH ECG EGG <br /> E GRILLE <br /> CAP AIRFLOW MONITOR <br /> EXISTING <br /> EF EXHAUST FAN �ji UNION LOUVER PLAN VIEW PROJECT: <br /> H FLANGE <br /> EA FM <br /> EA EACH FCU FAN COIL UNIT ® FLEX HOSE CONNECTION DOT EVERETT HQ <br /> EC ELECTRICAL CONTRACTOR;END CAP FD FIRE DAMPER REMOTELY OPERATED VOLUME DAMPER <br /> EP ELECTRICAL PANEL;END PLUG FM FREQUENCY MODULATION DOUBLE BELLOWS FLEX CONNECTION (YOUNG REGULATOR OR APPROVED) <br /> EPO EMERGENCY POWER OFF FP FIRE PROTECTION;FAN POWERED D SINGLE BELLOWS FLEX CONNECTION LOUVER(ELEVATION VIEW) Rr7'+�7 <br /> ESP EXTERNAL STATIC PRESSURE FSD COMBINATION FIRE/SMOKE DAMPER ► FLOW ARROW y .� 1 <br /> FTU FAN TERMINAL UNIT REDUCER AT �L ,,,fff111--��*www <br /> 1% BACK DRAFT COORDINATE DAMPER <br /> HECEILING APPURTENANCES. REl LL 10E <br /> FA F REURALARM GRD GRILLE,REGISTER,DIFFUSER SLOPE SYMBOL <br /> FDC FIREDEPARTMENTCONNECTION HVAC -ANNOTATION <br /> FDN FOUNDATION HC HEATING COIL BREAK OR CONTINUATION SYMBOL <br /> FLEX FLEXIBLE HVAC HEATING,VENTILATION AND AIR CONDITIONING DOWN SPOUT NOZZLE EQUIPMENT/LOUVER TAG <br /> FLR FLOOR �I CLEANOUT FLEX CONNECTION <br /> FP FIRE PROTECTION LAT LEAVING AIR TEMPERATURE <br /> FTG FOOTING LD LINEAR DIFFUSER EF EQUIPMENT <br /> VALVES FIRE DAMPER THROUGH WALL 2-1 DESIGNATION <br /> GA GAGE MA MIXED AIR L CONSECUTIVE PROJECT SITE -- ---- <br /> GALV GALVANIZED MOD MAKE UP AIR <br /> DAMPER;MODULATING MOTORIZED 2-WAY VALVE FD FD EQUIPUIPMENT# <br /> GC GENERAL CONTRACTOR MAU MAKE-UP AIR UNIT � � � FIRE DAMPER THROUGH FLOOR <br /> MUA MAKE-UPAIR MOTORIZED 3-WAY VALVE 709X B OADWAYA`E <br /> FLOOR OFEQUIP. 71V.UA YY Vi:. <br /> HP HORSEPOWER;HIGH PRESSURE C� CONTROL <br /> VALVE <br /> VALVE LOCATION $%f` � `=,A nO^O� <br /> HTG HEATING OA OUTSIDE AIR CONTROL VALVE FIRE/SMOKE DAMPER THROUGH WALL YY 982 <br /> HTR HEATER OBD OPPOSED BLADE DAMPER f- . / f <br /> S GRILLE.REGISTER.OR DIFFUSER TAG <br /> IAW IN ACCORDANCE WITH RA RETURN AIR RELIEF VALVE FSD FSD TYPE CODE <br /> ID INSIDE DIAMETERIDIMENSION RAT RETURN AIR TEMPERATURE Fbi BALLVALVE FIRE/SMOKE DAMPER THROUGH FLOOR WIDTH CONSULTANTS: <br /> IIN WC INCHES WATER COLUMN RTU ROOF TOP UNIT 3-WAY GATE VALVE I I HEIGHT <br /> MC MECHANICAL CONTRACTOR SA SUPPLY AIR BUTTERFLY VALVE SWG-MH VICINITY MAP <br /> MFR MANUFACTURER SAT SUPPLY AIR TEMPERATURE DIAPHRAGM VALVE ® Ap ACCESS DOORS xCFM <br /> MH MANHOLE SO SMOKE DAMPER;SMOKE DETECTOR CHECK VALVE _ <br /> MTD MOUNTED SF SUPPLY FAN NEEDLE VALVE AD L CFM <br /> SL SOUND LINED GLOBE VALVE <br /> N/A NOT APPLICABLE SLSM SOUND LINED SHEET METAL ,� 12x12 XSL ACOUSTICALLY LINED DUCT(X'THICK <br /> NC NORMALLY CLOSED SM SHEET METAL GLOBE VALVE ANGLE ----- SOUND LINING) <br /> NIC NOT IN CONTRACT SO SCREENED OPENING GLOBE VALVE 3-WAY <br /> NO NORMALLY OPEN;NUMBER SP STATIC PRESSURE D4 GATE VALVE R <br /> NOM NOMINAL PLUG VALVE CHANGE OF ELEVATION RISE(R)DROP(D) <br /> NTS NOT TO SCALE TG TRANSFER GRILLE <br /> TOD TOP OF DUCT � BALANCING VALVE <br /> OC ON CENTER HOSE BIBB P <br /> OD OUTSIDE DIAMETER VAV VARIABLE AIR VOLUME t] AUTO FLOW VALVE TURNING VANES <br /> OVHD OVERHEAD VD VOLUME DAMPER <br /> PERF PERFORATED «.r RETURN/EXHAUST/OUTSIDE AIR <br /> FOG POINT OF CONNECTION PIPING PIPING ACCESSORIES <br /> �- SUPPLY]TRANSFER AIR <br /> QTY QUANTITY BD STEAM BLOWDOWN <br /> BP BACKFLOW PREVENTER PUMP <br /> (R) RELOCATED 4MV <br /> CA CHILLED SED AIRWATER <br /> T DUCTWORK <br /> RCP REFLECTED CEILING PLAN CA <br /> CHILLED WATER RETURN 4AV MANUALAIRVENT GENERAL NOTES <br /> READ REQUIRED CHWS CHILLED WATER SUPPLY <br /> CLPS CLEAN LOW PRESSURE STEAM 4THAV AUTOMATIC AIR VENT <br /> RECTANGULAR DUCT <br /> SECT SECTION CNDS CONDENSATE T� <br /> SIM SIMILAR CNDWR CONDENSER WATER RETURN T HIGH CAPACITY AIR VENT 1VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK <br /> SPEC SPECIFICATION CNDWS CONDENSER WATER SUPPLY SUPPLY AIR DUCT PRIOR TO START OF CONSTRUCTION. <br /> STD STANDARD SHOCK ARRESTOR TURNING UP OR TOWARD <br /> DRAIN TANK OVERFLOW 8 DRAINS FS 2.OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF <br /> TBD TO BE DETERMINED DTR DUAL TEMPERATURE RETURN RECTANGULAR DUCT PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON,I.E.ANCHOR BOLT <br /> TI TENANT IMPROVEMENTS DTS DUAL TEMPERATURE SUPPLY FLOW SWITCH �i SUPPLY AIR DUCT DEPTHS,ETC. <br /> TOG TOP OF CONCRETE 4 TURNING DOWN OR AWAY <br /> TOS TOP OF STEEL EWI ENTERING WATER TEMPERATURE VACUUM BREAKER 3.CONCRETE EQUIPMENT CURBS,PIPING RAT SLABS,SUMP BASINS,AND HOUSEKEEPING <br /> TSP TOTAL STATIC PRESSURE Q RECTANGULAR DUCT PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY <br /> TYP TYPICAL FCD FLUE CONDENSATE DRAIN 4 PRESSURE GAUGE RETURN AIR DUCT THE GENERAL CONTRACTOR.WHERE PROVIDED,REFER TO STRUCTURAL INFO FOR <br /> FEED BOILER FEED WATER , TURNING UP OR TOWARD ADDITIONAL DETAILS. <br /> UG UNDERGROUND FOF FUEL OIL FILL TEMPERATURE SENSOR 4.HVAC EQUIPMENT SHALL NOT BE SIZED LARGER THAN THE NEXT LARGEST SIZE BASED <br /> UNO UNLESS NOTED OTHERWISE FOR FUEL OIL RETURN n RECTANGULAR DUCT ON LOAD CALCULATION,WSEC C403.2.2. <br /> FOS FUEL OIL SUPPLY �f' TEMPERATURE INDICATOR i RETURN AIR DUCT <br /> VFD VARIABLE FREQUENCY DRIVE FOV FUEL OIL VENT <br /> VS <br /> D VARIABLE SPEED DRIVE FM TURNING DOWN OR AWAY 5.000UPIED SPACES ARE MECHANICALLY VENTILATED.SYSTEMS ARE DESIGNED TO <br /> G NATURAL GAS FLOW METER RECTANGULAR�I����\//��� PROVIDE MINIMUM OUTSIDE AIR PER MECHANICAL CODE AND SHALL NOT EXCEED 150% <br /> W/ WITH 2#G NATURAL GAS-LOW PRESSURE,2 PSI I�JT CALCULATED VALUE,WSEC 403.2.68403.2.11.4. <br /> W/0 WITHOUT 5#G NATURAL GAS-LOW PRESSURE,5 PSI YSTRAINER W/BALLVALVE EXHAUST AIR DUCT <br /> WC WATER COLUMN TURNING UP OR TOWARD 6.COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: <br /> WG WATER GAUGE GE GENERATOR EXHAUST — PIPE SLEEVE GFWR GEO F A.MECHANICAL SYSTEMS,EQUIPMENT AND CONTROL SHALL BE COMMISSIONED PER WSEC <br /> - I <br /> GFWS GEO-FIELELD WATER RETURN RECTANGULAR DUCT D WATER SUPPLY STEAM TRAP EXHAUSTAIRDUCT 408.2. <br /> GWR GROUND WATER RETURN T TURNING DOWN OR AWAY B.COMMISSIONINGPLRN IS REQUIRED TO BE PREPARED BY CERTIFIED COMMISSIONING <br /> GWS GROUND WATER SUPPLY FETES PLUG PROFESSIONAL AND SUBMITTED TO THE AHU PRIOR TO FIRST MECHANICAL INSPECTION, <br /> ROUND DUCT PER WSEC 408.1.2.INCLUDE NARRATIVE OF ACTIVITIES,RESPONSIBILITIES OF Cx TEAM, <br /> HIP HIGH PRESSURE CONDENSATE SUCTION DIFFUSER W/STRAINER <br /> HIPS HIGH PRESSURE STEAM TURPPLY NING R DUCT SCHEDULE OF ACTIVITIES AND CONFLICT OF INTEREST PLAN. <br /> HWR HEATING WATER RETURN o REDUCED PRESSURE TURNING UP OR TOWARD <br /> HWS HEATING WATER SUPPLY BACKFLOW PREVEPlrOR a.PROVIDE SUMMARY OF REPORT OR COMPLIANCE CHECKLIST(SEE C408.1.4.2)AND <br /> ROUND DUCT PROVIDE TO OWNER PRIOR TO FINAL MECHANICAL INSPECTION. <br /> LPG LOW PRESSURE CONDENSATE I\(x TURNINSUPPLYG DOWN OR C.BALANCE SYSTEMS TO WITHAIR DUCT IN TOLERANCES SPECIFIED.FIRST BALANCE TO MINIMIZE <br /> LPG LOW PREDPROPATE GAS INSTRUMENTATION AND CONTROLS THROTTLING LOSSES THEN TO MEET DESIGN FLOW,WSEC 408.2.2. <br /> LPS LOW PRESSURE STEAM AWAY <br /> LWT LEAVING WATER TEMPERATURE ROUND DUCT <br /> RETURN AIR DUCT D.PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER PER WSEC <br /> MPC MEDIUM PRESSURE CONDENSATE aT THERMOSTAT TURNING UP OR TOWARD C103.6. REGISTRATION: <br /> MPS MEDIUM PRESSURE STEAM SENSOR ROUND DUCT E.PROVIDE MAINTENANCE MANUALS FOR ALL MECHANICAL EQUIPMENT,WSEC C103.6. <br /> L'l <br /> PCW PROCESS COLD WATER RETURN AIR DUCT F.PROVIDE OWNERS OPERATING PERSONNEL TRAINING FOR MECHANICAL EQUIPMENT, L <br /> PCWR PROCESS COOLING WATER RETURN CO CARBON MONOXIDE SENSOR I �P <br /> PCWS PROCESS COOLING WATER SUPPLY TURNING DOWN OR WSEC C103.6. Q�1 of <br /> AWAY <br /> PHW PROCESS HOT WATER CO2 CARBON DIOXIDE SENSOR ROUND DUCT <br /> G.PROVIDE WSEC COMPLIANCE FORMS AND CALCULATIONS,WSEC C103.6. <br /> PHWR PROCESS HOT WATER RETURN z <br /> OCC ON LIQUID GERAT RL REFR OCCUPANCY SENSOR EXHUASTAIRDUCT <br /> TURNING UP OR TOWARD T.MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2018 <br /> INTERNATIONAL MECHANICAL CODE .o <br /> II saa <br /> . <br /> RS REFRIGERATION SUCTION SD SMOKE DETECTOR ROUND DUCT 0 FPISTEBE��,�r4� <br /> RV REFRIGERATION VENT I.�y TURNING DOWN OR 8.ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED SS%2�Zr7 2 <br /> SCW SOFTENED COLD WATER GENERAL INFORMATION SYMBOLS �T <br /> SRV STEAM RELIEF VENT AWAY THIS IS AN EL ONIC SIGNATURE.DIGITAL <br /> STAMP ORIGINAL ON FILE AT MCKINSTRY. <br /> TOP TOP OF PIPE OVAL DUCT ISSUES: <br /> NEW MECHANICAL WORK <br /> SUPPLY AIR DUCT NO DATE DESCRIPTION <br /> - -- - - - FUTURE TI SCOPE B NEW WORK OTHER THAN MECHANICAL TURNING UP OR TOWARD 07-19-2022 XE PERMTSET <br /> l OVAL DUCT <br /> v POINT OF CONNECTION <br /> x SUPPLY AIR DUCT <br /> POINT OF DEMOLITION (� TURNING DOWN OR AWAY <br /> CL CENTERLINE FLEXIBLE DUCT <br /> XO (X) KEY NOTE REFERENCE <br /> PIPING RISER CALLOUT(CHW;HW) <br /> X PIPINGRISER# DEMOLITION NOTES <br /> PLAN NUMBER NVAC BASIS OF DESIGN <br /> X SHEET NUMBER WHERE PLAN SHOWN 1. DEMOLITION DRAWINGS ARE INCLUDED TO GIVE A COMMON BASIS FOR BIDDING AND MAY NOT SHOW <br /> EVERY ITEM TO BE DEMOLISHED.VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF <br /> DEMOLITION TO FACEPLATE WORK INDICATED BY THE CONTRACT DOCUMENTS.REWORK EXISTING IN MlWll�ll I-- <br /> TERMINATIONS,CONNECTIONS,ETC.,TO ACCEPT NEW WORK.PRIOR TO START OF ANY DEMO WORK, _ DESIGNED: A SADIGII <br /> X DETAIL OR DIAGRAM NUMBER VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. <br /> �X SHEET NUMBER - DRAWN: A SADIGH <br /> WHERE DETAIUDIAGRAM SHOWN 2. REMOVE EXISTING HVAC EQUIPMENT AS INDICATED,INCLUDING ASSOCIATED PIPING,CONTROL SYSTEMS, 4-TAT" .. <br /> AND APPURTENANCES. CHECKED: D.NA <br /> SECTION LETTER <br /> 3. REMOVE EXISTING DUCTWORK AS INDICATED.CAP EXISTING OPENINGS NOT BEING REUSED. JOB NO: 122224-001 <br /> X =T DOT`„" , <br /> X i SHEET NUMBER WHERE SECTION SHOWN 4. REMOVE EXISTING PIPING SERVING ITEMS TO BE REMOVED.CAP OR PLUG BRANCH LINES NOT BEING w� NEG os�.�aT"c"R E«wT"c ISSUED ON: <br /> REUSED. <br /> oENEUTxw Exwnnc SHEET TI�T'L+E.L� /'� <br /> X REVISION NUMBER-DENOTES NUMBER 5. GIVE OWNER THE OPPORTUNITY TO RETAIN ANY REMOVED ITEMS THAT ARE NOT BEING REUSED.DISPOSE "-TEETni�. MECHANICAL LEGEND, <br /> AND DATE WHEN REVISION OR ISSUE OF OTHER ITEMS LEGALLY. " xEw.,Ec,awcu "DOE° cesicu.nvnwc" <br /> OCISION ABBREVIATIONS, <br /> REVISION CLOUD-DENOTES AREA OF 6. CLEAN AND REFURBISH ITEMS INDICATED TO BE REMOVED AND REUSED PRIOR TO REUSE. T *"E�.,.*^*•"oaEw,�Low"oETwEEI.Ero"Ew„"R. „ <br /> CHANGE VICINITY MAP & B.O.D. <br /> X <br /> DETAIL REFERENCE OUTLINE <br /> WITH NUMBER AND SHEET LOCATION <br /> SHEET NUMBER:m 1oo 1 <br />