Laserfiche WebLink
instry <br /> if <br /> e Of Your Building <br /> McKINSTRY Co,LLC <br /> SEATTLE: <br /> 5005 3RD AVENUE S <br /> HVAC DUCT SPECIFICATION PO BOX 24567 <br /> DUCT SYSTEM PRESSURE CLASS DUCT MATERIALS FITTINGS FLEX SEAL CLASS CLEANLINESS DURING INSULATION(INDOOR,OUTDOOR) LINING MATERIALS SEISMIC SEISMIC NOTES SEATTLE,WA 98124 <br /> SPECIFICATION CONNECTIONIFLEX CONSTRUCTION INTL ENERGY CODE C403.2.7 CRITERIA IMPORTANCE 1-800-669-6223 <br /> TABLES 6 8 2& <br /> SPECIFCATION 233113&235100 SPECIFCATION 233113&235100 DUCT *DETERMINED BY CLIMATE NE&ASHRAE 90.1 FACTOR IP <br /> HVAC SUPPLY SMACNA+1/2"OR-1-PRESSURE GALVANIZED DUCT;GAUGE AND REINFORCEMENT SHALL ELBOWS:PURCHASED ADJUSTABLE ELBOWS 12-FOOT MAX.LENGTH WITH NO SMACNA SEAL CLASS A per FOLLOW BASIC"LEVEL A"SMACNA WITHIN CONDITIONED SPACE:R-3.3(<55F OR>105F) LINING WHERE INDICATED ON THE PLANS SEISMIC SUPPORT PER APPLICABLE IP=1.0 NOTES 1,2,3,4,5 www.mckinistry.com <br /> BE SMACNA OR BETTER IN ACCORDANCE WITH SMACNA+1' OFFSETS;USE JPL OR EQUAL IEC 2015 C403.2.7 CODE I LOCAL JURISDICTION.SEE <br /> LOW PRESSURE NOTE:MCKINSTRV BUILDS ALL LOW PRESSURE STANDARDS WHEN NOT IN A CONDITIONED SPACE:R-6 WITH ENGINEER TO CONSIDER LINING WHEN VELOCITY IS MECHANICAL SEISMIC SHEET WHEN PROJECT: <br /> DUCTWORK IN ACCORDANCE WITH+l"SMACNA RECTANGULAR MAY BE S+DRIVE APPROVED VAPOR BARRIER 1,400 FPM OR GREATER APPLICABLE. <br /> GUIDELINES TO MAXIMIZE PRODUCTION EFFICIENCY CL RADIUS OF 1.0 CIA ON DUCTS LARGER <br /> ROUND MAY BE SNAPLOCK. THAN 24' WHEN OUTSIDE:R-6 EXTERIOR INSULATION WITH DOT EWUTT HQ <br /> NO PRESSURE TEST REQUIRED PER IEC C403.2.7 APPROVED SIDE:RIWEXTERI BARRIER <br /> SPIN-IN/ATTO BRANCHES OK IN CONCRETE OR GROUND:R-3.3(HEATING ONLY) <br /> RTU <br /> HVAC RETURN SMACNA.112"OR-1"PRESSURE GALVANIZED DUCT;GAUGE AND REINFORCEMENT SHALL ELBOWS:CENTERLINE RADIUS OF 1.5 CIA OR 3-FOOT MAX.LENGTH WITH NO SMACNA SEAL CLASS LEVEL FOLLOW BASIC"LEVEL A"SMACNA WITHIN CONDITIONED SPACE:R-3.3 1"LINING ONLY WHERE INDICATED ON PLANS SEISMIC SUPPORT PER APPLICABLE IP=1.0 NOTES 1,2,3,4,5 <br /> BE SMACNA OR BETTER MITERED 90S WITH VANES OR PURCHASED OFFSETS;USE JPL OR EQUAL; C OKAY ENERGY CODE R4.4 per inch COOS/LOCAL JURISDICTION.SEE 712.2 T�--1T��E <br /> LOW PRESSURE NOTE:MCKINSTRV BUILDS ALL LOW PRESSURE ADJUSTABLE ELBOWS IN ACCORDANCE WITH APPEARS E NOT HAVE A WHEN NOT IN A CONDITIONED SPACE:RF WITH MECHANICAL SEISMIC SHEET WHEN R I�. P N 1 V <br /> DUCTWORK T ACCORDANCE WITH IO SMACNA RECTANGULAR TO HAVE S&D CONNECTIONS,ROUND SMACNA+1" FLEX AT EQUIP CONNECTIONS TO REQUIREMENT FOR NEG. APPROVED VAPOR BARRIER APPLICABLE. <br /> GUIDELINES TO MAXIMIZE PRODUCTION EFFICIENCY MAY BE SPIRAL COMPLY WITH SMACNA PRESS. <br /> CL RADIUS OF 1.0 DIA ON DUCTS LARGER APPLICABLE PRESSURE CLASS WHEN OUTSIDE:R-e EXTERIOR INSULATION WITH <br /> NO PRESSURE TEST REQUIRED PER IEC C403.2.7 SNAP LOCK PIPE STANDARD THAN 24'CIA APPROVED VAPORANEATHER BARRIER <br /> TAPS:CONICAL OR BOOT-SHE <br /> SPIN-IN IATTO BRANCHES OK <br /> NOTES: <br /> 1.ALL DUCTWORK TO BE FABRICATED IN ACCORDANCE WITH MCKINSTRV DUCT CONSTRUCTION STANDARDS/SUBMITTALS WHICH MEET OR EXCEED SMACNA GUIDELINES <br /> 2.ALL DIMENSIONS SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS. <br /> 3.THE MECHANICAL ENGINEER RESERVES THE RIGHT TO AUTHORIZE DEVIATIONS TO THESE STANDARDS TO ACCOMMODATE UNIQUE SITUATIONS AS APPLICABLE 70(1 T+T Dell AT-l�I7A�T A�7C <br /> 4.USE DOUBLE WIDTH VANES UNLESS OTHERWISE NOTED ON THE DRAWINGS /�777�`1�V��'L�T7+1T��lJt1LJY A AVE <br /> 6.REFERENCE DUCT CONSTRUCTION AND EXPOSED CLASS5+USE OF DUCTWORK FOR TEMPORARY HEATING/ IFICATNG IONS DURING <br /> M MATRIX <br /> CONSTRUCTION NOT ALLOWED WITHOUT SPECIAL APPROVAL BY THE ENGINEER EVERETT,WA 98201 <br /> CONSULTANTS: <br /> HVAC PIPING SPECIFICATION Hid.wx awwm AIR CONDITIONING DX GAS PACKAGED ROOF TOP UNIT SCHEDULE REPLACEMENT <br /> DESCRIPTION <br /> 1G 1GGm nclelacRiPTpx 111— dAdlUlMllURdlTddl MANd—Tw11,PRGwci did— RA Go UNIWETAGM RTU., <br /> LOCATION ROOF <br /> �xn SCOPE QUALIFIER(PROJECT PHASE,FUTURE,ALTERNATE,ETC) REPIACEMENT <br /> TYPEANDARIRANGEMEW(INDOORIOU1 M,HORIZONTAWERTIM) OUTGOORIVERTICAL <br /> ARE4ISYSTEMSERVED FIRST FLOOR <br /> ,wrev „a, MANUFACTURER DATA <br /> as MANUFACTURER GOODMAN <br /> MODEL NUMBER GPG1dd6100-M11C <br /> UNIT EXTERIOR FINISH TYPE BAXEDENAMEL <br /> as rueewcwnwwe,wiwnexwsewiwnw uswwemw CONTROLSINTERFACEIPROTOCOL DOC <br /> xx °N OVERALL PHYSICAL DIMENSIONS <br /> rsm DEPTH x WIDTH.HEIGHT IN dTx51Y dSt/Z' <br /> ,wee FACTORY(ADAPTER)CURB PROVIDED YES <br /> OPERATING WEIGHT,INCLUDE BASE WEIGHT LBS SUS <br /> PERFORMANCE <br /> DESIGN OUTSIDE AIR TEMPERATURE IDS IWB,DEGREESF 85167 <br /> LEAVING UNIT SUPPLY AIR TEMPERATURE IDS IWB,DEGREES R WM ISS28 <br /> TOTALISENSIBLE COOUNGGAPACItt MBH 4B.5G6.S <br /> TOTPL G...NG INPUTIOUTPUT(MBH) 10D18) <br /> DESIGN SUPPLY AIRFLOW(CFMD 1525 <br /> MIN OUTSIDE AIR(CFM) 200 <br /> SUPPLY DUCT DESIGN EXTERNAL STATIC PRESSURE .C. 0.5 <br /> SUPPLY FAN&MOTOR QUANTITY 1 <br /> SUPPLY FAN MOTOR TYPE MULTI SPEED(DIRECT IXRNE <br /> SUPPLY FAN CONFIGURATION(BLOW THRU I DRAW THRU) DRAW THRU <br /> SUPPLY FAN POWER MOTOR SUE,PER FAN(MI BM <br /> AIRSIDE ECONOMIZER INCLUDED? YTS <br /> FILTER EFFICIENCY MI <br /> REFRIGERANT TYPE R41M <br /> REFRIGERANT QUANDTY OZ 107 <br /> CODE MINIMUM WOUND EFFICIENCY(SEER) 14 <br /> UNIT WOUND EFFICIENCY SEER I EER) 14111 <br /> RETURN CONFIGURATION(SIDE,TOP,BOTTOM) BOTTOM <br /> RETURNOPENINGEVE NxWORf 18-X16- <br /> DISCHARGE CONFIGURATION(SIDE,TOP,BOTTOM) BOTTOM <br /> DISCHARGE OPENING SIZE Hx W OR FT') 18-X16' <br /> ELECTWCAL <br /> OUANTNVOFELECTRICALCONNECTIONS 1 <br /> VOLTAGE I PHASE EACH CONNECTION 20803011PH <br /> MINIMUM CIRCUITAMPACffY MCA,PMPS NS <br /> OVERCURRENT PROTECTION ONDICATE MOCP OR MRS 45(MOCP) <br /> MINIMUM SHORT CIRCUIT CURRENT RATING SCCR NV 5 <br /> 115V CONVENIENCE OUTLET PROWDED MISTING <br /> SMOKE DETECTOR PROVIDED WITH UNIT R NA <br /> POWER AND LOW VOLTAGE WIRE ROUTING EXTERANL <br /> DISCONNECTS PROVIDED BY FIELD EXTERNAL <br /> ACOUSTICAL&SEISMIC <br /> UNIT SUPPORT ISOIATION REQUIREMENTS SEE STRUCTURAL OWGS <br /> DUCT CONNECTION ISOLATION REQUIREMENTS WA <br /> NOTES: <br /> 1.PROVIDED WITH LOW LEAKAGE,100%OUTSIDE AIR ECONOMIZER(PER WSEC)WITH BAROMETRIC DAMPER <br /> 2.PRONDE UNIT WITH CURB ADAPTER. <br /> REGISTRATION: <br /> �pF <br /> O� <br /> FCISTE0.EOGlr� <br /> SS/OMAL6e� <br /> �.lP 2022 <br /> THIS IS AN SIGNATURE.DIGITAL <br /> STAMP ORIGINAL <br /> ON NI ON FILE AT MCKINSTRV. <br /> ISSUES: <br /> NO DATE DESCRIPTION <br /> 07-19-2022 MECHAML',ALPERMTSEI' <br /> DESIGNED: A SADIGI <br /> DRAWN: ASADIGH <br /> CHECKED: D.MA <br /> JOB NO: 122224-001 <br /> ISSUED ON: <br /> SHEET TITLE: <br /> SCHEDULE AND <br /> SPECIFICATIONS <br /> SHEET NUMBER: <br /> NM60 <br />