GENERAL NOTES <br /> THE GENERAL NOTES SUPPLMENT THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS.IF A <br /> CONFLICT IS NOTED,CONTACT THE ENGINEER PRIOR TO CONSTRUCTION. <br /> REFERENCE TO CODES,RULES,REGULATIONS,STANDARDS,OR REQUIREMENTS OF <br /> REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE DATE <br /> OF SUBMISSION. <br /> CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND FOR fe Of Your Building <br /> CHECKING DIMENSIONS, NOTIRY THE OWNER AND ENGINEER OF ANY DISCREPANCY AND <br /> RESOLVE CONFLICTS PRIOR TO CONSTRUCTION. MCKINSTRY Co,LLC <br /> DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS <br /> ARE NOT SPECIFICALLY INDICATED,BUT ARE OF SIMILAR CHARACTER TO DETAILS INDICATED, 2 <br /> USE SIMILAR DETAIL OF CONSTRUCTION,SUBJECT TO REVIEW BY THE ENGINEER OF RECORD. SEATTLE: <br /> THE DRAWINGS INDICATE THE STRUCTURE IN ITS FINAL CONDITION.THE CONTRACTOR SHALL _ 5005 3RD AVENUE S <br /> PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION.SUCH PO BOX 24567 <br /> MEASURES SUCH MEASURES INCLUDE,BUT MAY NOT BE LIMITED TO:BRACING,SHORING AND SEATTLE,WA 98124 <br /> SEQUENCINGTO MAINTAIN STABILITY DURING CONSTRUCTION. 1-800-669-6223 <br /> INFORMATION SHOWN ON THE DRAWINGS RELATED TO EXISTING CONDITIONS REPRESENTS THE <br /> PRESENT KNOWLEDGE BUT WITHOUT CERTAINTY OF ACCURACY.CONTRACTOR SHALL REPORT www.mckinstry.com <br /> ANY DISCREPANCY TO THE OWNER AND ENGINEER OF RECORD.THE CONTRACTOR SHALL NOT RTU <br /> DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE PROJECT. <br /> ENGINEER. EVERETT DOT <br /> THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EQUIPMENT,SUPPORTS,AND SEISMIC (E)2X12 JOISTS @ 16"OC <br /> RESTRAINTS PRIOR TO FABRICATION.IDENTIFICATION OF EXISTING UTILITIES THAT INTERFERE I <br /> WITH EQUIPMENT INSTALLATION IS ALSO THE RESPONSIBILITY OF THE CONTRACTOR. RTU <br /> CONTRACTOR TO NOTIFY THE ENGINEER IF FIELD CONDITIONS RESTRICT THE INSTALLATION OF <br /> COMPONENTS OR RESTRAINTS SHOWN ON THE DRAWINGS.CONSTRUCTION TOLERANCES: REPLACEMENT <br /> UNLESS NOTED OTHERWISE,STANDARD CONSTRUCTION TOLERANCES SHALL BE BASED 1 ROOF PARTIAL PLAN <br /> ON THE REQUIREMENTS OF THE AISC CODE OF STANDARD PRACTICE AND ACI 117, <br /> STANDARD SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND SCALE:1/8"=1'-0" <br /> MATERIALS.ANY CONSTRUCTION TOLERANCES NOTED IN THE DRAWINGS OR SPECIFICATION <br /> ARE TO BE CONSIDERED IN CONJUNCTION WITH THE STANDARD TOLERANCES AS INDICATED NOTES: <br /> ABOVE,UNLESS SPECIFICALLY NOTED AS AN EXCEPTION TO,OR IN LIEU OF A STANDARD 1.IN)DENOTES"NEW";(E)DENOTES EXISTING. <br /> TOLERANCE. 2.'X'DENOTES"HOLD DOWN"LOCATION;PROVIDE CONNECTION PER SKETCH. <br /> 3.CONTRACTOR TO COORDINATE LOCATION OF NEW MECHANICAL UNIT WITH MECHANICAL DRAWINGS. <br /> SCOPE <br /> MCKINSTRY'$STRUCTURAL SCOPE IS LIMITED TO THE REPLACEMENT OF THE 709 N. BROAD WAY AVE <br /> CURRENT RTU WITH THE NEW RTU AND THE CONFIRMING OF THE EXISTING <br /> STRUCTURE.THE WEIGHT OF THE INCOMING RTU IS 635#INCLUDING THE OVERSIZED EV E R ETT, WA 98201 <br /> CURB THE UNIT RESTS ON. (N)MECH UNIT PER <br /> DESIGN CRITERIA SCHEDULE <br /> CONSULTANTS: <br /> CODES:IBC 2018 WITH WASHINGTON AMENDMENTS,ASCE 7-16,NDS <br /> DEAD LOADS: PL&SCREW PER NOTE 1 <br /> (N)WT=635# LXWXH=51"X47"x42-112" —————— <br /> (E)ROOFING MATERIAL: W=10 PSF <br /> LIVE LOADS: <br /> ROOF LIVE LOAD=20 PSF <br /> SNOW LOADS: — IN)ADAPTER CURB <br /> Pg=25 PSF \\ <br /> Is=1.0 <br /> SEISMIC LOADS: \ <br /> SDS=0.95g DESIGN SHORT PERIOD ACCELERATION \ <br /> Ip=1.0 SEISMIC IMPORTANCE FACTOR III=III <br /> WIND LOADS: II (N)(5)1/4"0 SCREW AT <br /> III— I EA CORNER MIN, <br /> V3SEC=110 MPH EXP=C INFILL AT 12"OC(TYR) <br /> IW=1.0 <br /> HT=13'AT ROOF (E)UNIT CURB <br /> (E)4 PLY BUILT UP ROOFING <br /> (E)3/4"SHEATHING <br /> WOOD <br /> FRAMING LUMBER SHALL BE KILN DRIED OR MC-19 AND GRADED/MARKED PER WCLB STANDARD <br /> GRADING RULES FOR WEST COAST LUMBER.CONTRACTOR TO PROVIDE THE MINIMUM (E)2X12 JOIST @ 16"OC <br /> STANDARDS AS FOLLOWS: <br /> JOISTS(2X MEMBERS):DOUG FIR#2(FB=900 PSI,FV=180 PSI,E=1600 KSI) 2 CONNECTION DETAIL <br /> JOISTS(3X MEMBERS):DOUG FIR#1(FB=1000 PSI,FV=180 PSI,E=1700 KSI) SCALE:NTS <br /> BEAMS&STRINGERS:DOUG FIR#1(FB=1350 PSI,FV=170 PSI,E=1600 KSI) <br /> POSTS(4X MEMBERS):HEM FIR#1(FC=1000 PSI,E=1600 KSI) NOTE: <br /> POSTS(6X MEMBERS):DOUG FIR#1(FC=1350 PSI,E=1500 KSI) 1.IF RTU IS NOT FASTENED TO ADAPTER CURB,PROVIDE PL 14GAx <br /> STUDS,PLATES,&MISC:DOUG FIR#2(FB=900 PSI,MIN) 60-8",GALV AT EA CORNER;FASTEN WITH(4)-1/4"0 TOP& <br /> BOT,(8)SCREWS MIN,TYP. <br /> MISCELLANEOUS <br /> REFER TO ARCHITECTURAL,MECHANICAL,ELECTRICAL,CIVIL,OR OTHER DRAWINGS FOR <br /> DIMENSIONS NOT SHOWN,INCLUDING INFORMATION SUCH AS:SIZE AND LOCATION OF <br /> CURBS,EQUIPMENT HOUSEKEEPING PADS,WALL AND FLOOR OPENINGS,BLOCK OUTS, <br /> FLOOR DEPRESSIONS,SUMPS,DRAINS,ANCHOR BOLTS,EMBEDDED ITEMS,ARCHITECTURAL <br /> TREATMENT,ETC.CONTRACTOR TO COORDINATE DIMENSIONS AND RESOLVE <br /> DISCREPANCIES OR CONFLICTS PRIOR TO CONSTRUCTION. <br /> \�,AN BR <br /> �� OF WA <br /> SECTION �1yy <br /> secT —SECTION NUMBER \ / �F�SFfGISTERE <br /> YYY <br /> sot —SHEET NUMBER S/ONANEXPIRES: 1-30-24 <br /> THIS IS AN ELECTRONIC SIGNATURE.DIGITAL <br /> DETAIL <br /> STAMP ORIGINAL ON FILE AT MCKINSTRY <br /> �—DETAIL NUMBER I GRID LINES <br /> s-3o1 —SHEET NUMBER I REGISTRATION: <br /> ELEVATION <br /> NORTH ARROW <br /> 3 ELEVATION NUMBER <br /> s-3o1 —SHEET NUMBER ——————— FUTURE CONSTRUCTION; <br /> ARCHITECTURAL PROFILE <br /> E� L TOP OF FLOOR EXISTING ELEMENTS <br /> �>-- <br /> ELEVATION FUTURE ELEMENTS <br /> ISSUES: <br /> NO DATE DESCRIPTION <br /> EARTH 1IS_201=A _ MATCHLINE 7/18/22 PERMIT SET <br /> 1/S-201-B <br /> MISCELLANEOUS SYMBOLS <br /> DESIGNED: RB <br /> DRAWN: IRS <br /> CHECKED: JWG <br /> JOB NO: 122224 <br /> SHEETTITLE: <br /> GENERAL NOTES, <br /> PARTIAL PLAN <br /> AND CONNECTION <br /> DETAIL <br /> SHEETNUMBER: <br /> S 001 <br />