Laserfiche WebLink
ABBREVIATIONS PIPING IDENTIFICATION DUCTWORK ACCESSORIES GRILLE/REGISTER/DIFFUSER NECHAMCALROEX <br /> rF"Fae, yYAO EV6II PROJECT SPECIFIC PROJECT SPECIFIC BEREGRE, <br /> RMAB Ro.LL s T�`re I�str� <br /> AD ACCESS DOOR AC AIR CONGRIONING ---- RETURN PIPING MD6B SCI3ECUIEA*D SPEX;IF'ICAIRIN @AJ�EVNTe➢�6 <br /> AFF ISOVEFINISHEDFLOOR AHD AIR HANDLING UNIT SUPPLY PIPING' SUPPLY GRILLE CEILINGSUPPLYAIROIFFUSER M121 i/e0/YourBuildinq <br /> AFC AWVE FINISHED GRADE SRXUISI� <br /> BDD BAERGMFr DAMPER }I-L��� MDKINSTRY Co,LLC <br /> BHP BRAKE HORSEPOWER BOO BOTTOM OF DUCT Imo+'+ RETURN OR EXHAUST GRILLE <br /> BOP BOTTOM OF PIPE COWING COIL � CEILING RETURNGRILLE <br /> BOT BOTTOM CC PIPING FITTINGS <br /> CRU DOMPUTERROOMUNIT OR TRANSFER AIR GRILLE <br /> GL CENTER LINE Ci COWING TOWER iEE DP L� VOLUME DAMPER SEATTLE: <br /> BEG cEIUNG cv CONSTANT VOLUME - TEE oowN ® 50053RD AVENUES <br /> CFM CUBIC FEET PER MINUTE <br /> CO CARBON MONOXIDE DB DUCT BOARD TEE DN WI ELBOW CEILING EXHAUSTGRILLEPO BOX 27 <br /> .2 CARBON DIOXIDE DIFF DIFFUSER Ai MOTOIROPERATEDDAMPER SEATTLE,WA 98124 <br /> GSR CURRENT SENSING RELAY DMPR DAMPER TEE UP WI ELBOW 4564 <br /> " K'ELBOW UP ® LINEAR DIFFUSER(CEILING) 1-800E69-6223 <br /> DISCH DISCHARGE EA EXHAUSTAIR J 60°ELBOW DN <br /> DN DOWN EAT ENT <br /> ERINGAIRTEMPERATURE O LINEAR DIFFUSER(WALL) www.mckinsW.cpm <br /> DS DISCONNECT SWITCH;DOOR SWITCH ECG EGGCRATEGREM BA AIRFLOW MONITOR <br /> EF EXHAUSTFAN , UNION O PROJECT: <br /> (E) EXISTING FLANGE FM LOWER PLAN VIEW T�/����]���TT T�Tp��EA EACH FCU FPNCAMPEOILUNIT ® FLEX HOSE CONNECTION JJ�/1 E Vf RET 1 HQ <br /> EC ELECTRICAL CONTPACTOR;END CAP FD FIRE DAMPER REMOTELY OPERATED VOLUME DAMPER <br /> EP ELECTRICAL PANEL:ENDPLUG FM FREQUENCY MODULATION m DOUBLE BELLOWS FLE%CONNECTION (YOUNG REGULATOR OR APPROVED) <br /> ERB EMERGENCY POWER OFF FP FIRE PROTECTION:FAN POWERED D SINGLE BELLOWS FLEX CONNECTIONLOWER(ELEVATION VIEW) ��T <br /> ESP E%TERNALSTATICPRESSURE FSD COMBINATION FIREAUVOKE DAMPER ► FLOW ARROW 0 • /� <br /> FTU FAN TERMINAL UNIT REWCER RTFT-�1�r%T{,%� <br /> FFA DC FIE AM DPER <br /> E PARTMENTCONNECNON BAD GRILLE,REGISTER,DIFFUSER SLOPE SYMBOL ��1 OORDSACK�TE NTH CEILING APPURTENANCES. S RE L +�� <br /> FON FOUNDATION HC HEATING COIL BREAK OR CONTINUATION SYMBOL HVAC-ANNOTATION <br /> FLE% FLEXIBLE HVAC HEATING,VENTILATION AND AIR CONDITIONING DOWN SPOUT NOZZLE EDUIPMENT/LOUVER TAG <br /> FLR FLOOR 'I CLEANOUT FLE%CONNECTION <br /> FP FIRE PROTECTION UT LEAVING MRTEMPERATURE <br /> FTG FOOTING LED LINEAR DIFFUSER EF EWIPMENT <br /> VALVES FIRE GWPERTHROUGH WALL DESIGNATION <br /> GA GAGE MA MOTO O CONSECUTIVE PROJECT SITE <br /> ED GALVANIZED MOD MOTOR OPERATED DAMPER;MODULATING C� MOTORIZED 2-WAY VALVE F➢ FD EQUIPUIPMENT# <br /> GC GENERAL CONTRACTOR MCA MARE-BRUCUPAIR UNIT MOTORIZED SWAY VALVE �� FIRE DPMPEft THROUGH FLOOR 709NB OADWAYAVE <br /> MCA MAKE-DPMR V" FLOOR OF EQUIP. y >LV lJl� !il/YYt11 liVl: <br /> HP HORSEPOWER;HIGH PRESSURE lya CONTROL WINE <br /> VALVE LOCATION x`I'A nO^O� <br /> B. <br /> HEATING OA OUTSIDE B p$ CELIEFV VALVE FIREISMOKE DAMPERTHRODGH WALL WA>OG <br /> HTR HEATER OBD OPPOSED BIFDE DAMPER <br /> RELIEF VALVE P GRILLE,REGISTER,OR C DIFFUSER TAG <br /> LAW IN SIDE <br /> DAANCEWITH RA RETURN AIR FSO FSD TYPE CODE <br /> Ip INSIDE DIAATERCOUMNSION RAT ROBE TOP(UNIT TEMPERATURE L61 BALLVA.ESAVE FIREISMONE DAMPER THROUGH FLOOR WIDTH CONSULTANTS: <br /> IN WC INCHES WATER COLUMN RTU ROOF TOP UNIT SWAY GATE VALVE HEIGHT <br /> MC MECHANICAL CONTRACTOR SA SUPPLY AIR BUTTERFLYVALVE B—H VICINITY MAP <br /> HER MANUFACTURER SAT SUPPLYAIRTEMPERATURE 6 DIAPHRAGM VALVE ® O ACCESS DOORS xOEM <br /> MH MANHOLE SD SMOKE DAMPER;SMOKE DETECTOR E CHECK VALVE <br /> MITI MOUNTED SF SUPPLY FAN NEEDLE VALVE AD �CFM <br /> SL SOUND LINED GLOBEVALVE <br /> NIA NOTWPJCABLE BUIX SOUND LINED SHEET METAL -12x12%PL- ACOUSTICALLY LINED DUCT DC THICK <br /> NO <br /> NORMALLY CLOSED SM SHEET METAL ILOSEVALVE ANGLE SOUND LINING) <br /> NIC NOT IN CONTRACT SO SCREENED OPENING GLOBEVALVE&WAY <br /> NO NORMALLY OPEN:NUMBER SP STATIC PRESSURE IJxI GATE VALVE �R <br /> NOM NOMINAL I`j{ PLUG VALVE CHANGE OF ELEVATION RISER)DROPHH <br /> TUTS NOT TO SCALE TG MROFERGRILLE <br /> TOD TOP OF DUCT IOI BALANCING VALVE <br /> 1ON CENTER HOSE BIBB TURNING VANES <br /> 00 OUTSIDE DIAMETER VAV VARIABLE AIRVOLUME t5 AUTO FLOW VALVE <br /> OVHD OVERHEAD VD VOLUME DAMPER <br /> PERF PERFORATED +. RETURN I EXHAUST I OUTSIDE AIR <br /> PW POINTOFCONNECTION ELINQ PIPING ACCESSORIES <br /> SUPPLYITRANSFERAIR <br /> QTY QUANTITY BE SIDOWBO <br /> BE <br /> BACKFLOW PREVENTER ® PUMP <br /> (R) RELOCATED 4MV <br /> CA IMPRESSED R T DUCTWORK <br /> RCP REFLECTED CEILING PLAN CHWR CHILLED WATER RETURN MANUAL MR VENT <br /> READ REWIRED GHWS CHILLELOWPRSUPPLY 4AV GENERAL NOTES <br /> UPS CLEAN LOW PRESSURE STEAM AUTOMATIC AIR VENT <br /> SECT SECTION CNDS CONDENSATE Q�V RE IT ANGULAR DUCT <br /> SIM SIMILAR CNDWR CONDENSER WATER RETURN HIGHCAPACITYAIRVENT 1.VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK <br /> SPEC SPECIFICATION CNDWS CONDENSER WATER SUPPLY SUPPLY AIR DUCT PRIOR TO START OF CONSTRUCTION. <br /> STD STANDARD SHOCKARRESTOR TURNING UP OR TOWARD <br /> DRAIN TANKOVERFLOW&DRAINS PS 2.OBTARA'NON NOT OFSiRUSLY M ENGINEER PRIORAGREED URN, ANC <br /> N OF <br /> Ti TO BE ERMINED DTR DUALTEMPERATURE RELIIRN RECTANGULPROUCi PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON,I.E.ANCHOR BOLT <br /> FLOW SWITCH pEPMS,ETC. <br /> TI TENANT IMPROVEMENTS DTS DUAL TEMPERATURE SUPPLY v\ TURNING <br /> URNINGD DUCT <br /> TOO TOP OF CONCRETE TUPNING DOWN OR AWAY <br /> TOP TOP OF STEEL EWT ENTERING WATER TEMPERATURE VACUUM BREAKER 3.CWCRE SHOWFORAPPROXIMATEIMENT CURBS, LOCATION AN SUMP BASINS,AND HOUSEKEEPING <br /> TSP TOTAL STATIC PRESSURE y RECTANGULAR DUCT PAD GENE ALCNTRACTOR.MERE <br /> APPROXIMATE LOCATION AND SIZE STRUCTNDARE TOBEPROFOR BY <br /> TYP TYPICAL FEE FWECONED—E DRAIN PRESSURE GAUGE �/I RETURN PIR DUCT THE GENERAL WHERE PROVIDED,REFER TO STRUCTURAL INFO FOR <br /> FEED BOILER FEED WATER ��/ TURNING UP OR TOWARD ODDmONPL DETAILS. <br /> US UNDERGROUND FOR FUEL OIL FILL TEMPERATURE SENSOR 4.WAD EQUIPMENT SHALL NOT BE SIZED LARGERTHAN THE NEXTLARGEST SIZE BASED <br /> UNO UNLESS NOTED OTHERWISE FOR FUEL OIL RETURN RECTANGULAR DUCT ON LOAD CALCULATION,USED U11—. <br /> FOS FUEL OIL SUPPLY w TEMPERATURE INDICATOR RETURN AIR DUCT <br /> VPO VARIABLE FREQUENCY DRIVE FOV FUELOILVENT TURNING.WNORAWAY SOCCUPIED SPACESARE MECHANICALLYVENDLATED.SYSTEMS PRE DESIGNED TO <br /> ND VARIABLE SPEED DRIVE <br /> G NATURAL GAS FLOW METER � ���/UO PROVIOETE VA UE NB C93.E MR PERMECHANICPL CODEANO SHALL NOT EXCEED 160% <br /> W1 WITH 2#G NATURAL GAS LOW PRE SSURE,2 PSI RECTANGUIM I�T CALCULATED VALUE,WPEC403.2.66403.2.114. <br /> W10 WITHOUT ASG NATURALGAS—PRESSURE,SPSI YSTRAINER WI BPLLVALVE EXHAUST MRO <br /> VrC WATER COLUMN TUPNING UP OR TO TO <br /> WARD fi.COMPLETION PND COMMISSIONING FOR MECHANICAL SYSTEMS: <br /> WG WATER GAUGE GE GENERATOR EXHAUST — PIPE SLEEVE <br /> GFWE GEO-FIELD WATER RETURN RECTANGUIOAR DUCT A,MECHANICAL SYSTEMS,EOUIFMENT AND CONTRW SHALL BE COMMISSIONED PER WSEC <br /> GFWS GEO-FIELD WATER SUPPLY ®- STEAM TRAP EXHAUSTAIRDUCT 400.2. <br /> GWR GROUND WATER RETURN TURNINGDOWNORAWAV BCOMMISSIONING PLAN IS REQUIRED TO BE PREPARED BY CERTIFIED COMMISSIWING <br /> GWS GROUND WATER SUPPLY RUES PLDG ROUND DUCT PROFESSIONAL PND SUBMITTED TO THE AHJ PRIOR TO FIRST MECHANICAL INSPECTION, <br /> HPC HIGHPRESSURECONDENSATE SUCTION DIFFUSER WI STRAINER PER WSEC 4B0.1.2.INCLUDE NARRATNE OF ACTIVITIES,RESPONSIBILITIES OF C.TEAM, <br /> HI <br /> HIGH PRESSDRE STEAM = SUPPLY AIRDUCT SCHEDULE OF ACTIVITIES AND CONFLICT OF INTEREST PLAN. <br /> HOUR HEATING WATERRETURN REDUCED PRE SSURE TURNING UP ORTOWARD <br /> HWS HEATING WATERSUPPLY BACKPLOW PREVENTOR ..PROVIDE SUMMARY OF REPORT OR COMPLIANCE CHECKLIST(SEE CHUI42)AND <br /> ROUND WCT PROVIDE TO OWNER PRIOR TO FINAL MECHANICAL INSPECTION. <br /> _PC LOW PRESSURE CONDENSATE Y% TUPNING—PLYAIRDUCTDOWN C.BALANCE SYSTEMS TO WITHIN TOLERANCES SPECIFIED,FIRST BALANCE TO MINIMIZE <br /> LPG LIWE REDPROPANEGAP INSTRUMENTATION AND CONTROLS THR07LINGLOBBES THEN TO MEET DESIGN FLOW,WSEC 4M.2.2. <br /> LPS LOW PRESSURE STEAM AWAY <br /> LLAT LEAVING WATER TEMPERATURE ROUND WCT <br /> NETDRN AIR DUCT O.PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNERPER W5EC <br /> MPO MEDIUM PRESSURE CONDENSATE OT-�/ TURNING UP OR TOWARD C103.6. <br /> MPS MEDIUM PRESSURE STEAM THERMOSTAT REGISTRATION: <br /> V SENSOR ROUND WCT E.PROVIDE MAINTENANCE MANUALS FOR ALL MECHANICAL EWIPMENT,WSEC C103.6. <br /> PCW PROCESS COLD WATER RETURN AIR DUCT F.PROVIDE OWNERSOPENATING PERSONNELTRAINING FOR MECHANICAL EQUIPMENT. L <br /> PCWR PROCESSOOWINGWATERRETURN ® CARBON MONOXIDE SENSOR 1/ �VP4 <br /> PD. PROCEMMOLINGWATERSUPPLY Y TURNING DOWN OR WSEC C103.6. <br /> CO CARBON DIOXIDE SENSOR AWAY <br /> 0`'WD A <br /> PHW PROCESS HOT WATER ROUND WCT G.PRWIDE WSEC COMPLIANCE FIRMS AND CALCULATIONS,WSEC C1036. <br /> PHWR PROCESS HIT WATER RETURN TEX URNING <br /> ORTO <br /> OCC OCCUPANCY SENSOR TUMlING UP OR TOWARD TMINIMUM VNALM C ANICALQUANTITIES WILL COMPLY WITH OR EXCEED THE 2010 <br /> CT <br /> RL REFRIGERATION LIQUID <br /> INTERNATIONAL MECHANICAL CODE, <br /> RS REFRIGERATION SUCTION SO SMOKE DETECTOR ROUND DUCT Q 1sT = <br /> RV REFRIGERATION VENT GENERAL INFORMATION SYMBOLS TURNING DOWN OR B.PLL SYSTEMS WILL BE INSDLAIED PS PRESCRIBED AN EL�T�FyVON�c SG��TURE.QIGITPL <br /> L'�y EXHAUST AIR DUCT <br /> THISIIS <br /> SCW MANSOFTENED LCOLD FVENTWATER <br /> SW STEAM RELIEF VENT AWAY <br /> TOP TOP OF PIPE TaMP Daic ucN FlLR nT MCKiNaiay. <br /> NEWMECHANICALWORK OVAL DUCT ISSUES: <br /> WPPLYMN DUCT NO DATE DESCRIMION <br /> ------ FUTURE TI SCOPE&NEW VlORK OTHER THAN MECHANICAL TURNING UP OR TOWARD <br /> OT-19-ZOZ2 SEE <br /> OVAL DUCT <br /> POINT OF CONNECTION <br /> SUPPLYAIR ODCi <br /> 0 POINT OF DEMOLITION ('X TURNING DOWN OR AWAY <br /> Q CENTERLINE FLEXIBLE DUCT <br /> O O KEY NOTE REFERENCE <br /> XRUR. DEMOLITION NOTES <br /> NUMBER <br /> X SHEET NUMBER WHERE PLAN SHOWN WINGS ARE INCLUDED TO ONE ACOMMON BASIS FOR BIDDING AND MAY HOT SHOW <br /> E BEDEMOLISHED.VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF <br /> DEMOLITION TO FACEPLATE WORK INDICATED BY THE CONTRACT DOCUMENTS.REWORK EXISTING <br /> TER MNATIONS,CONNECTIONS,ETC.,TOACCEPTNEWWORK.PRIORTOSTARTOFANYBEMOWORK, DESIGNED: ASAugR <br /> DETAILORDNGRPM NUMBER VERIFY EXISTING CONCITONSAND NOTIFY ENGINEER OFANY DISCREPANCIES FOR RESOLUTION. <br /> X SHEET NUMBER 2, REMOVE EXISTING HVAC EQUIPMENT AS INDICATED,INCLUDING ASSOCIATED PIPING,CONTROL SYSTEMS, DRAWN: ASNYQI <br /> WHERE DUARLDIAGRAM SHOWN —APPURTENANCES. CHECKED'. DMA <br /> SECTIWLETTER 3, REMOVE EXISTING WCTWORKAS INDICATED.CAP EXISTING OPENINGS NOT BEING REUSED. <br /> SHEET NUMBER " 09F EATpuM uienw JOB NO. T2222441D1 <br /> X WHERE SECTION SHOWN ISSUED ON: <br /> 4. REMOVE EXISTING PIPING SERVING ITEMS BE REMOVED.CAP OR PLUG BRANCH LINES NOT BEING <br /> REUSED. <br /> SHEET TI(T�LE4_2LJ /''� <br /> Cf::--RE11IONNUM1E <br /> R-DENOTESNUMBER B. GIVE OWNER THE OPPORTUNITYTO RETAINANY REMOVED ITEMS THAT ARE NOT BEING REI15E0.DISPOSE �..Mo.r.i� MECHANICAL LEGEND, <br /> ACDC RED <br /> ND DATE WHEN REVISION OR ISSUE OF OTHER ITEMS LEGALLY. .w....e. . ABBREVIATIONS, <br /> s axv.uimxomau,ero,awuu�.uzee is i�vsruuuunw.rcn. <br /> NEVISIONCLOOD DENOTESAREA OF 6. CLEAN AND REFURBISH ITEMS INDICATED TO BE REMOVED AND REUSED PRIOR TO REUSE. " ^'"°°°""`°' ° °®°""'^°'�' <br /> CHANGE VICINITY MAP& B.O.D. <br /> WITH NUMBER <br /> SHUTLINE <br /> WITH NUMBER AND SHEET LOCATION <br /> SHEET NUMBER. <br /> L Wo 1 <br />