My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 2024 Plans 2025-07-02
>
Address Records
>
PACIFIC AVE
>
916
>
Plans
>
916 PACIFIC AVE 2024 Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 7:12:59 AM
Creation date
6/16/2025 9:33:52 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Permit
B2409-025
Year
2024
Notes
MINOR TENANT IMPROVEMENTS OF AN EXISTING UNOCCUPIED SPACE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL LEGEND ABBREVIATIONS PIPING LEGEND DRAWING INDEX o <br /> SYMBOL DESCRIPTION ABBR DESCRIPTION ABER DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION SHEET NUMBER DESCRIPTION 2 <br /> e DETAIL SYMBOL: A = IDENTIFYING NUMBER ABV ABOVE L LENGTH LIGHT LINEWORK INDICATES 3 CAP PIPE END CAP PO.1 COVER SHEET,GENERAL INFO&INDEX <br /> AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE EXISTING PIPING OR EQUIPMENT _D PIPE TURNING DOWN OR AWAY P0.2 PLUMBING SPECIFICATIONS <br /> B B =SHEET WHERE DETAIL IS SHOWN AHU AIR HANDLING UNIT LBS POUNDS ������������������������� INDICATES PIPING OR EQUIPMENT r/I <br /> AL ACOUSTIC LINED LF LINEAR FOOT/FEET TO BE REMOVED PIPE TURNING UP OR TOWARD P1.1 PLUMBING FLOOR PLAN-DEMO p CL <br /> DETAIL SYMBOL: A = IDENTIFYING NUMBER AP ACCESS PANEL LVG LEAVING P2.1 PLUMBING FLOOR PLAN Z <br /> �p APO AIR PRESSURE DROP LNG LOW WALL GRILLE SS SS SANITARY SEWER-OUTSIDE BUILDING AND PIPE TURNING DOWN OR AWAY(TEE) uj <br /> B =SHEET WHERE DETAIL IS TAKEN ARCH ARCHITECT ARCHITECTURAL LWR LOW WALL REGISTER BELOW GROUND �-' <br /> B C C =SHEET WHERE DETAIL IS SHOWN ARV AUTOMATIC RELIEF VALVE or LWr LEAVING WATER TEMPERATURE Sp SD STORM DRAIN-OUTSIDE BUILDING AND REDUCER(NOT TYPICALLY SHOWN) U N <br /> ACID RESTISTANT VENT BELOW GROUND PIPE CONNECTION -- <br /> ARW ACID RESTISTANT WASTE MAX MAXIMUM W U <br /> p SECTION SYMBOL: A = IDENTIFYING LETTER MBH 1000 BRITISH THERMAL W WASTE(&SOIL) -ABOVE GROUND-INTERIOR 0 ` <br /> B B =SHEET WHERE SECTION IS SHOWN BDD BACKDRAFT DAMPER UNITS PER HOUR PIPE ANCHOR m Q <br /> FLOW PREVENTER W WASTE(&SOIL) -BELOW GROUND-INTERIOR PIPE Z. <br /> BFP BACK <br /> MCC MOTOR CONTROL CENTER V VENT (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) <br /> BHP BRAKE HORSEPOWER MECH MECHANICAL fw <br /> BG BELOW GROUND MFR MANUFACTURER = PIPE ALIGNMENT GUIDES W? <br /> ARW ARW ACID RESISTANT WASTE LL § <br /> BJ BETWEEN JOISTS MIN MINIMUM (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) �a <br /> SECTION SYMBOL: A = IDENTIFYING LETTER BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS ARV ARV ACID RESISTANT VENT <br /> BAC B =SHEET WHERE SECTION IS TAKEN BTUH BRTRSH THERMAL UNITS PER HOUR MTD MOUNTED - CW COLD WATER-DOMESTIC HB HOSE BIBB GENERAL PLUMBING NOTES <br /> C =SHEET WHERE SECTION IS SHOWN MTG MOUNTING s�?€ <br /> C CENTIGRADE HW HOT WATER-DOMESTIC -�' WH/NFWH WALL HYDRANT or NON-FREEZE WALL HYDRANT <br /> CC COOLING COIL N/A NOT APPLICABLE 'I CO/WCO CLEANOUT or WALL CLEANOUT 1. PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR,MATERIALS,AND <br /> CD CEILING DIFFUSER N/C NORMALLY CLOSED --- HWC HOT WATER CIRCULATING-DOMESTIC EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE,OPERATIONAL PLUMBING <br /> SECTION CUT LINE INDICATOR CFM CUBIC FEET PER MINUTE N/O NORMALLY OPEN RD RD RAINWATER DRAINAGE-ABOVE GROUND ______0 FCO/SCO FLUSH CLEANOUT or SURFACE CLEANOUT SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, <br /> CG CEILING GRILLE NC NOISE CRITERIA INCLUDING ALL NECESSARY FEES AND PERMITS. 2727 Oakes Ave. <br /> CI CAST IRON NIC NOT IN CONTRACT RD RD RAINWATER DRAINAGE-BELOW GROUND FDC FIRE DEPARTMENT CONNECTION suite 100 <br /> O KEYED REFERENCE NOTE OR SHEET NOTE CLG CEILING NTS NOT TO SCALE L 2. DO NOT SCALE DRAWINGS.INSTALL SYSTEMS BASED ON ACTUAL FIELD Everett,WA 98201 <br /> CO CLEANOUT ORD ORD RAINWATER DRAINAGE OVERFLOW-ABOVE GROUND Ir) <br /> FIRE SPRINKLER ALARM GONG MEASUREMENTS. <br /> CONC CONCRETE OA OUTSIDE AIR ORD ORD RAINWATER DRAINAGE OVERFLOW-BELOW GROUND <br /> 8 POINT OF CONNECTION(POC)SYMBOL CONN CONNECT or CONNECTION OBD OPPOSED BLADE DAMPER 3. PIPING AND EQUIPMENT ANCHORAGE:PROVIDE SEISMIC RESTRAINTS AND REVISIONS <br /> CONST CONSTRUCTION O/C ON CENTER D D DRAJN-INDIRECT ® AD ��DRAIN ANCHORAGE PER SPECIFICATIONS AND THE INTERNATIONAL BUILDING CODE. <br /> P7-1 PLUMBING FIXTURE REFERENCE(REFER TO SCHEDULE) CONT CONTINUATION OD OUTSIDE DIAMETER OPNG OPENING RV RELIEF VALVE VENT ® FD or FFD FLOOR DRAIN or FUNNEL FLOOR DRAIN <br /> CR CONDENSATE RETURN EQUIPMENT IDENTIFICATION(REFER TO SCHEDULES) FS FLOOR SINK 4• PIPE SIZES:WHERE A SECTION OF PIPE BETWEEN TAKEOFFS DOES NOT HAVE <br /> AHU-1 <br /> PIPE SLOPE DIRECTION ® A SIZE INDICATED,IT SHALL BE SAME SIZE AS SECTION UPSTREAM.IN <br /> DB DECIBLE or DRY BULB PCV PRESSURE CONTROL VALVE f OO OD OVERFLOW DRAIN GENERAL,AS VOLUME FLOW RATE DECREASES,PIPE SIZE SHALL REMAIN <br /> OA MEDICAL GAS OUTLET IDENTIFICATION(REFER TO SCHEDULE) DDC DIRECT DIGITAL CONTROL PD PRESSURE DROP -ICW - ICW INDUSTRIAL COLD WATER LARGE UNTIL A SMALLER SIZE IS INDICATED.NOTE THAT SOME PIPE SIZES <br /> DIA DIAMETER PH or 0 PHASE -SCW - SCW SOFT COLD WATER OO RD ROOF DRAIN ARE INDICATED ON ASSOCIATED DEVICE SCHEDULE. <br /> DIM DIMENSION PLCS PLACES SHUTOFF VALVE(AS SPECIFIED FOR PIPING SYSTEM) <br /> MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL DN DOWN PLC POINT OF CONNECTION -FCW - FCW COLD WATER(FLUSHING SYSTEM) 5. HANDICAP FIXTURES:PLUMBING FIXTURES AND TRIM IN HANDICAP ACCESSIBLE <br /> DPR DAMPER POUA POINT OF USE ALARM KHW---- IHW INDUSTRIAL HOT WATER ma BV BALL VALVE AREAS SHALL COMPLY WITH ALL ADA STANDARDS AND REQUIREMENTS AS <br /> DWG DRAWING PRV PRESSURE REDUCING VALVE WELL AS STATE AND LOCAL CODES. <br /> MEDICAL GAS ALARM PANEL MOUNTED IN WALL PSI POUNDS PER SQUARE INCH -KHW -- KHW KITCHEN HOT WATER N CKV CHECK VALVE <br /> E-100 EXHAUST AIR PSIG POUNDS PER SQUARE INCH GAGE I\I BFV BUTTERFLY VALVE 6. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF WALLS, <br /> NUMBER INDICATES CFM QUANTITY -KHWC----- KHWC KITCHEN HOT WATER CIRCULATING FLOORS,AND CEILINGS. ,CjD t\r <br /> F» MEDICAL GAS OUTLET EA EACH R-100 RETURN AIR -LHW -- LHW LAUNDRY HOT WATER IMSI BFV BUTTERFLY VALVE W MEMORY STOP "flag aAsq�tT'� <br /> EAT ENTERING AIR TEMPERATURE NUMBER INDICATES CFM QUANTITY '�` / 7. COORDINATE EXACT LOCATION OF STUB-UPS TO PLUMBING FIXTURES WITH O R� <br /> EF EXHAUST FAN RA RETURN AIR -LHWC----- LHWC LAUNDRY HOT WATER CIRCULATING BAL VA BALANCING VALVE ARCHITECTURAL PLANS. PROVIDE MEANS TO CONNECT TO ABOVE GROUND �e <br /> EG EXHAUST GRILLE RAG RETURN AIR GRILLE NPW NPW NON-POTABLE WATER BSV COMBINATION BALANCING/SHUTOFF VALVE PIPING&INSTALLATION OF DRAINS. <br /> 1 REVISION ELECTRIC or ELECTRICALSION CLOUD AND REVISION NUMBER READ REQUIRED <br /> M C ELEVATION RPBP REDUCED PRESSURE BACKFLOW IW IRRIGATION WATER ACV 2-WAY MODULATING CONTROL VALVE W/ACTUATOR 8. COORDINATE EXACT LOCATION OF UTILITY SERVICES WITH THE LOCAL UTILITY <br /> E Sv9.941 <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM SUPPLIERS AND EXISTING PLANS. CONTRACTOR TO FIELD VERIFY. <br /> PREVENTOR DI DI DEIONIZED WATER l <br /> � ACV 3-WAY MODULATING CONTROL VALVE W/ACTUATOR ESP EXTERNAL STATIC PRESSURE "` <br /> XX BINARY(YES/NO)SENSING SWITCH RPM REVOLUTIONS PER MINUTE 9. FIELD VERIFY ALL EXISTING CONDITIONS AND LOCATIONS OF STUB-INS PRIOR <br /> L1VI ENTERING WATER TEMPERATURE DW DW DISTILLED WATER <br /> (PIPE OR DUCT MOUNTED) EXST or(E) EXISTING H EXHAUST S-100 SUPPLY AIR CS CS CONDENSER WATER SUPPLY 2-POSITION CONTROL VALVE TO INSTALLATION. 8122124 <br /> NUMBER INDICATES CFM QUANTITY CG PRV PRESSURE REDUCING VALVE 10. PLUMBING CONTRACTOR SHALL NOTIFY ENGINEER OF ANY PROPOSED <br /> SA SUPPLY AIR CR CR CONDENSER WATER RETURN CHANGES TO DESIGN PRIOR TO TAKING ACTION. <br /> XX BINARY(YES/NO)SENSING SWITCH FA FACEENHEIT AREA SF SUPPLY FAN CWS CWS CHILLED WATER SUPPLY-COOLING RV RELIEF VALVE <br /> (SURFACE MOUNTED) FCO FLOORCLEANOUT <br /> SHT SHEET 11. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE <br /> SIM SIMILAR CWR CWR CHILLED WATER RETURN-COOLING <br /> Cy RAS FLOW MEASUREMENT STATION LLE <br /> FCU FAN COIL UNIT <br /> NIT EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FIRINGS, <br /> XX ANALOG SENSING DEVICE FD FLOOR DRAIN SO STA�EPRESSURE RL RL LIQUID LINE-REFRIGERANT STIR Y-TYPE STRAINER TRANSITIONS,VALVES,AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR C)(PIPE OR DUCT MOUNTED) FDPR FIRE DAMPER A COMPLETE,WORKABLE INSTALLATION. <br /> FFD FUNNEL FLOOR DRAIN SO FT SQUARE FOOT/FEET RS IRS SUCTION LINE-REFRIGERANT GLV GLOBE VALVE <br /> FF FINAL FILTER SS STAINLESS STEEL 12. PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL COMPLY WITH THE <br /> ANALOG SENSING DEVICE STD STANDARD HG HG HOT GAS LINE-REFRIGERANT OSY VA OUTSIDE SCREW AND YOKE VALVE <br /> (SURFACE MOUNTED) O <br /> XX FLR FLOOR ® LATEST ACCEPTED VERSION OF THE IBC. COORDINATE WITH ARCHITECTURAL <br /> FPM FEET PER MINUTE THK THICK HWS IXP VA EXPANSION VALVE HWS HOT WATER HEATING SUPPLY PLANS. <br /> FPS FEET PER SECOND C'4 / 1 I I <br /> Q ANALOG SENSING DEVICE(SURFACE MOUNTED) FT FOOT/FEET TP TRAP PRIMER or TEST PLUG HWR HWR HOT WATER HEATING RETURN 13. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING. �J LLJ <br /> L� <br /> (APPROPRIATE FOR MEASURED FLUID) FV FACE VELOCITY TYPICAL 0CITY FOS FCV FLOW CONTROL VALVE FOS FUEL OIL SUPPLY W <br /> SUBSCRIPT LETTER(X)INDICATES: TU TERMINAL UNIT 14. SUPPORT HORIZONTAL LINES OF COPPER TUBING WITH HANGERS SPACED NOT <br /> FOR FOR FUEL OIL RETURN I�I UNION MORE THAN 6-FEET,CENTER TO CENTER FOR ALL PIPE SIZES.ALL PIPES �/ <br /> A-ALARM PRESSURE SENSOR GA GAGE or GAUGE V/ II <br /> D-DIFFERENTIAL PRESSURE GAL GALLON UBC UNIFORM BUILDING CODE SHALL BE SUPPORTED AT ELBOWS,BRANCHES,AND RISERS. J <br /> UFC UNIFORM FIRE CODE G G NATURAL GAS 4- FLANGES <br /> F-FLOW RATE GALV GALVANIZED UMC UNIFORM MECHANICAL CODE LPG LPG UQUID PETROLEUM GAS 15. SUPPORT HORIZONTAL CAST IRON SOIL PIPE WITH HANGER,OR PIER,TWO U Q <br /> H-HUMIDITY GPM GALLONS PER HOUR UPC UNIFORM PLUMBING CODE b THREADED DRAIN PLUG FOR EACH 5-FOOT PIPE LENGTH.LOCATE SUPPORT CLOSE TO JOINTS <br /> L-LOW LIMN GPM GALLONS PER MINUTE UG UNDERGROUND LPS LIPS LOW PRESSURE STEAM SUPPLY <br /> P-PRESSURE(STATIC) j MALE(GARDEN)HOSE CONNECTION WITH CAP EXCEPT,PIPE EXCEEDING 5-FEET IN LENGTH SHALL BE SUPPORTED AT NO <br /> T-TEMPERATURE H HEIGHT UH UNIT HEATER LPR LPR LOW PRESSURE STEAM CONDENSATE RETURN MORE THAN 5-FOOT INTERVALS.SUPPORTS SHALL BE LOCATED ON BOTH LL O <br /> V-VELOCITY&VOLUME FLOW RATE HD HEAD 4 TP TEST PLUG SIDES OF ALL JOINTS AND WITHIN 6'OF THE JOINTS. ` <br /> HP HORSEPOWER VA VALVE MPS MPS(20) MEDIUM PRESSURE STEAM SUPPLY V <br /> HTG HEATING VAC VACUUM NUMBER IN PARENTHESIS INDICATES PSI O 16. PROVIDE WATER HAMMER ARRESTORS(SHOCK ABSORBERS)AT ALL PIPE Q <br /> HVAC HEATING,VENTILATION AND VAV VARIABLE AIR VOLUME MPR MPR(20) MEDIUM PRESSURE STEAM CONDENSATE RETURN T SHOCK ARRESTOR LOCATIONS WHERE VALVE CLOSURES(SUCH AS FLUSH VALVES)MAY CAUSE <br /> AIR CONDITIONING VD VOLUME DAMPER NUMBER IN PARENTHESIS INDICATES PSI WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. (n� <br /> HWG HIGH WALL GRILLE VEL VELOCITY HIPS HPS(100)HIGH PRESSURE STEAM SUPPLY �T TH or TI THERMOMETER(TEMPERATURE INDICATOR) a- <br /> VFD VARIABLE FREQUENCY DRIVE NUMBER IN PARENTHESIS INDICATES PSI <br /> HWR HIGH WALL REGISTER 17. ON THE <br /> PLUMBING CLEANOUT LOCATIONS ARE NOT ALWAYS ESTABLISHED <br /> VTR VENT THRU ROOF <br /> HZ HERTZ LOCATE <br /> THE PLUMBING PLANS IN ORDER TO GIVE THE PLUMBER AS. AS A TO <br /> HPR HPR(100)HIGH PRESSURE STEAM CONDENSATE RETURN II B STIR BASKET STRAINER LOCATE PLUMBING CLEANOUTS IN THE MOST ACCESSIBLE AREAS. AS A LJJ w <br /> ID INSIDE DIAMETER W WIDE NUMBER IN PARETHESIS INDICATES PSI MINIMUM,PROVIDE CLEANOUTS AS REQUIRED BY THE UNIFORM PLUMBING /� <br /> IE INVERT ELEVATION W/ WITH PR PR STEAM CONDENSATE RETURN(PUMPED) I?P PI PRESSURE INDICATOR CODE. CLEANOUTS THAT MUST BE INSTALLED IN PIPES THAT ARE DIFFICULT U W <br /> IN INCH or INCHES W/o WITHOUT TO ACCESS SHALL BE EITHER WALL OR FLOOR CLEANOUTS SERVICED FROM <br /> INSUL INSULATION WB WET BULB ATV ATV ATMOSPHERIC VENT THE FLOOR ABOVE. FLOOR CLEANOUTS SHALL BE LOCATED SO AS TO BE <br /> INV INVERT W� WALL CC�EONT AAV AUTOMATIC AIR VENT SERVICED FROM CORRIDORS,TOILET OR JANITOR ROOMS WHEREVER POSSIBLE. <br /> MA MA COMPRESSED MEDICAL AIR z <br /> KW KILOWATT WGE WASTE GAS EVACUATION LA LA COMPRESSED LABORATORY AIR MANUAL AIR VENT 18. TRAP PRIMERS AND ARRESTORS:TRAP PRIMER ACTUATORS AND WATER LLJ <br /> KWH KILOWATT HOUR WPD WATER PRESSURE DROP Q HAMMER ARRESTORS SHALL BE LOCATED TO BE ACCESSIBLE EITHER THROUGH Q <br /> WT WEIGHT MV MV MEDICAL VACUUM ACCESSIBLE CEILING OR WALL ACCESS DOORS.REFER TO SPECIFICATION FOR <br /> 02 02 OXYGEN ® PUMP(DIAGRAM) WHERE ARRESTORS NEED TO BE LOCATED. \ O <br /> 420 N20 NITROUS OXIDE 19. TRAP PRIMER LINE SIZE TO EACH FLOOR DRAIN OR FUNNEL DRAIN SHALL BE O <br /> 42 N2 NITROGEN kNl FLEXIBLE CONNECTOR 1/2`DIAMETER. N O <br /> CO2 CO2 CARBON DIOXIDE 20. DRAINAGE PIPING SHALL BE PROTECTED FROM CONCRETE USING 10-MIL <br /> A A COMPRESSED AIR INDICATES ASSEMBLY OF PIPING COMPONENTS PLUMBERS TAPE. n <br /> (AS NOTED OR DIAGRAMED) LL LL <br /> V V VACUUM 21. SANITARY PIPING SHALL BE SLOPED AT A MINIMUM OF 1/4"PER FOOT. <br /> LV LV LABORATORY VACUUM 22. DOMESTIC COLD WATER PIPING AND FIRINGS SHALL BE SEAMLESS TYPE"L" <br /> WGE WGE WASTE GAS EVACUATION COPPER WITH 95-5 SOLDER. SOLDER CONTAINING LEAD IS NOT ice.No. 242095 <br /> ACCEPTABLE. <br /> 23. EFFICIENT WATER HEATER SUPPLY PIPING:HOT WATER SUPPLY PIPING SHALL °TAW°" CEI <br /> BE PLUMBED IN COMPLIANCE WITH C404.3 IN CURRENT WSEC. c�e,.ae�er ON <br /> 24. PLUMBING CONTRACTOR SHALL PRESSURE TEST PIPING PRIOR TO COVERING <br /> AND SUBMIT TEST REPORT TO ENGINEER. <br /> 25. COMMISIONING:HOT WATER SUPPLY SYSTEM SHALL BE COMMISSIONED IN PERMIT SET <br /> ACCORDANCE WITH C408.3 IN CURRENT WSEC. 08/22/24 <br /> COVER SHEET <br /> AND GENERAL <br /> INFO <br /> P0. 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.