GENERAL LEGEND ABBREVIATIONS PIPING LEGEND DRAWING INDEX o <br /> SYMBOL DESCRIPTION ABBR DESCRIPTION ABER DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION SHEET NUMBER DESCRIPTION 2 <br /> e DETAIL SYMBOL: A = IDENTIFYING NUMBER ABV ABOVE L LENGTH LIGHT LINEWORK INDICATES 3 CAP PIPE END CAP PO.1 COVER SHEET,GENERAL INFO&INDEX <br /> AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE EXISTING PIPING OR EQUIPMENT _D PIPE TURNING DOWN OR AWAY P0.2 PLUMBING SPECIFICATIONS <br /> B B =SHEET WHERE DETAIL IS SHOWN AHU AIR HANDLING UNIT LBS POUNDS ������������������������� INDICATES PIPING OR EQUIPMENT r/I <br /> AL ACOUSTIC LINED LF LINEAR FOOT/FEET TO BE REMOVED PIPE TURNING UP OR TOWARD P1.1 PLUMBING FLOOR PLAN-DEMO p CL <br /> DETAIL SYMBOL: A = IDENTIFYING NUMBER AP ACCESS PANEL LVG LEAVING P2.1 PLUMBING FLOOR PLAN Z <br /> �p APO AIR PRESSURE DROP LNG LOW WALL GRILLE SS SS SANITARY SEWER-OUTSIDE BUILDING AND PIPE TURNING DOWN OR AWAY(TEE) uj <br /> B =SHEET WHERE DETAIL IS TAKEN ARCH ARCHITECT ARCHITECTURAL LWR LOW WALL REGISTER BELOW GROUND �-' <br /> B C C =SHEET WHERE DETAIL IS SHOWN ARV AUTOMATIC RELIEF VALVE or LWr LEAVING WATER TEMPERATURE Sp SD STORM DRAIN-OUTSIDE BUILDING AND REDUCER(NOT TYPICALLY SHOWN) U N <br /> ACID RESTISTANT VENT BELOW GROUND PIPE CONNECTION -- <br /> ARW ACID RESTISTANT WASTE MAX MAXIMUM W U <br /> p SECTION SYMBOL: A = IDENTIFYING LETTER MBH 1000 BRITISH THERMAL W WASTE(&SOIL) -ABOVE GROUND-INTERIOR 0 ` <br /> B B =SHEET WHERE SECTION IS SHOWN BDD BACKDRAFT DAMPER UNITS PER HOUR PIPE ANCHOR m Q <br /> FLOW PREVENTER W WASTE(&SOIL) -BELOW GROUND-INTERIOR PIPE Z. <br /> BFP BACK <br /> MCC MOTOR CONTROL CENTER V VENT (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) <br /> BHP BRAKE HORSEPOWER MECH MECHANICAL fw <br /> BG BELOW GROUND MFR MANUFACTURER = PIPE ALIGNMENT GUIDES W? <br /> ARW ARW ACID RESISTANT WASTE LL § <br /> BJ BETWEEN JOISTS MIN MINIMUM (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) �a <br /> SECTION SYMBOL: A = IDENTIFYING LETTER BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS ARV ARV ACID RESISTANT VENT <br /> BAC B =SHEET WHERE SECTION IS TAKEN BTUH BRTRSH THERMAL UNITS PER HOUR MTD MOUNTED - CW COLD WATER-DOMESTIC HB HOSE BIBB GENERAL PLUMBING NOTES <br /> C =SHEET WHERE SECTION IS SHOWN MTG MOUNTING s�?€ <br /> C CENTIGRADE HW HOT WATER-DOMESTIC -�' WH/NFWH WALL HYDRANT or NON-FREEZE WALL HYDRANT <br /> CC COOLING COIL N/A NOT APPLICABLE 'I CO/WCO CLEANOUT or WALL CLEANOUT 1. PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR,MATERIALS,AND <br /> CD CEILING DIFFUSER N/C NORMALLY CLOSED --- HWC HOT WATER CIRCULATING-DOMESTIC EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE,OPERATIONAL PLUMBING <br /> SECTION CUT LINE INDICATOR CFM CUBIC FEET PER MINUTE N/O NORMALLY OPEN RD RD RAINWATER DRAINAGE-ABOVE GROUND ______0 FCO/SCO FLUSH CLEANOUT or SURFACE CLEANOUT SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, <br /> CG CEILING GRILLE NC NOISE CRITERIA INCLUDING ALL NECESSARY FEES AND PERMITS. 2727 Oakes Ave. <br /> CI CAST IRON NIC NOT IN CONTRACT RD RD RAINWATER DRAINAGE-BELOW GROUND FDC FIRE DEPARTMENT CONNECTION suite 100 <br /> O KEYED REFERENCE NOTE OR SHEET NOTE CLG CEILING NTS NOT TO SCALE L 2. DO NOT SCALE DRAWINGS.INSTALL SYSTEMS BASED ON ACTUAL FIELD Everett,WA 98201 <br /> CO CLEANOUT ORD ORD RAINWATER DRAINAGE OVERFLOW-ABOVE GROUND Ir) <br /> FIRE SPRINKLER ALARM GONG MEASUREMENTS. <br /> CONC CONCRETE OA OUTSIDE AIR ORD ORD RAINWATER DRAINAGE OVERFLOW-BELOW GROUND <br /> 8 POINT OF CONNECTION(POC)SYMBOL CONN CONNECT or CONNECTION OBD OPPOSED BLADE DAMPER 3. PIPING AND EQUIPMENT ANCHORAGE:PROVIDE SEISMIC RESTRAINTS AND REVISIONS <br /> CONST CONSTRUCTION O/C ON CENTER D D DRAJN-INDIRECT ® AD ��DRAIN ANCHORAGE PER SPECIFICATIONS AND THE INTERNATIONAL BUILDING CODE. <br /> P7-1 PLUMBING FIXTURE REFERENCE(REFER TO SCHEDULE) CONT CONTINUATION OD OUTSIDE DIAMETER OPNG OPENING RV RELIEF VALVE VENT ® FD or FFD FLOOR DRAIN or FUNNEL FLOOR DRAIN <br /> CR CONDENSATE RETURN EQUIPMENT IDENTIFICATION(REFER TO SCHEDULES) FS FLOOR SINK 4• PIPE SIZES:WHERE A SECTION OF PIPE BETWEEN TAKEOFFS DOES NOT HAVE <br /> AHU-1 <br /> PIPE SLOPE DIRECTION ® A SIZE INDICATED,IT SHALL BE SAME SIZE AS SECTION UPSTREAM.IN <br /> DB DECIBLE or DRY BULB PCV PRESSURE CONTROL VALVE f OO OD OVERFLOW DRAIN GENERAL,AS VOLUME FLOW RATE DECREASES,PIPE SIZE SHALL REMAIN <br /> OA MEDICAL GAS OUTLET IDENTIFICATION(REFER TO SCHEDULE) DDC DIRECT DIGITAL CONTROL PD PRESSURE DROP -ICW - ICW INDUSTRIAL COLD WATER LARGE UNTIL A SMALLER SIZE IS INDICATED.NOTE THAT SOME PIPE SIZES <br /> DIA DIAMETER PH or 0 PHASE -SCW - SCW SOFT COLD WATER OO RD ROOF DRAIN ARE INDICATED ON ASSOCIATED DEVICE SCHEDULE. <br /> DIM DIMENSION PLCS PLACES SHUTOFF VALVE(AS SPECIFIED FOR PIPING SYSTEM) <br /> MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL DN DOWN PLC POINT OF CONNECTION -FCW - FCW COLD WATER(FLUSHING SYSTEM) 5. HANDICAP FIXTURES:PLUMBING FIXTURES AND TRIM IN HANDICAP ACCESSIBLE <br /> DPR DAMPER POUA POINT OF USE ALARM KHW---- IHW INDUSTRIAL HOT WATER ma BV BALL VALVE AREAS SHALL COMPLY WITH ALL ADA STANDARDS AND REQUIREMENTS AS <br /> DWG DRAWING PRV PRESSURE REDUCING VALVE WELL AS STATE AND LOCAL CODES. <br /> MEDICAL GAS ALARM PANEL MOUNTED IN WALL PSI POUNDS PER SQUARE INCH -KHW -- KHW KITCHEN HOT WATER N CKV CHECK VALVE <br /> E-100 EXHAUST AIR PSIG POUNDS PER SQUARE INCH GAGE I\I BFV BUTTERFLY VALVE 6. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF WALLS, <br /> NUMBER INDICATES CFM QUANTITY -KHWC----- KHWC KITCHEN HOT WATER CIRCULATING FLOORS,AND CEILINGS. ,CjD t\r <br /> F» MEDICAL GAS OUTLET EA EACH R-100 RETURN AIR -LHW -- LHW LAUNDRY HOT WATER IMSI BFV BUTTERFLY VALVE W MEMORY STOP "flag aAsq�tT'� <br /> EAT ENTERING AIR TEMPERATURE NUMBER INDICATES CFM QUANTITY '�` / 7. COORDINATE EXACT LOCATION OF STUB-UPS TO PLUMBING FIXTURES WITH O R� <br /> EF EXHAUST FAN RA RETURN AIR -LHWC----- LHWC LAUNDRY HOT WATER CIRCULATING BAL VA BALANCING VALVE ARCHITECTURAL PLANS. PROVIDE MEANS TO CONNECT TO ABOVE GROUND �e <br /> EG EXHAUST GRILLE RAG RETURN AIR GRILLE NPW NPW NON-POTABLE WATER BSV COMBINATION BALANCING/SHUTOFF VALVE PIPING&INSTALLATION OF DRAINS. <br /> 1 REVISION ELECTRIC or ELECTRICALSION CLOUD AND REVISION NUMBER READ REQUIRED <br /> M C ELEVATION RPBP REDUCED PRESSURE BACKFLOW IW IRRIGATION WATER ACV 2-WAY MODULATING CONTROL VALVE W/ACTUATOR 8. COORDINATE EXACT LOCATION OF UTILITY SERVICES WITH THE LOCAL UTILITY <br /> E Sv9.941 <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM SUPPLIERS AND EXISTING PLANS. CONTRACTOR TO FIELD VERIFY. <br /> PREVENTOR DI DI DEIONIZED WATER l <br /> � ACV 3-WAY MODULATING CONTROL VALVE W/ACTUATOR ESP EXTERNAL STATIC PRESSURE "` <br /> XX BINARY(YES/NO)SENSING SWITCH RPM REVOLUTIONS PER MINUTE 9. FIELD VERIFY ALL EXISTING CONDITIONS AND LOCATIONS OF STUB-INS PRIOR <br /> L1VI ENTERING WATER TEMPERATURE DW DW DISTILLED WATER <br /> (PIPE OR DUCT MOUNTED) EXST or(E) EXISTING H EXHAUST S-100 SUPPLY AIR CS CS CONDENSER WATER SUPPLY 2-POSITION CONTROL VALVE TO INSTALLATION. 8122124 <br /> NUMBER INDICATES CFM QUANTITY CG PRV PRESSURE REDUCING VALVE 10. PLUMBING CONTRACTOR SHALL NOTIFY ENGINEER OF ANY PROPOSED <br /> SA SUPPLY AIR CR CR CONDENSER WATER RETURN CHANGES TO DESIGN PRIOR TO TAKING ACTION. <br /> XX BINARY(YES/NO)SENSING SWITCH FA FACEENHEIT AREA SF SUPPLY FAN CWS CWS CHILLED WATER SUPPLY-COOLING RV RELIEF VALVE <br /> (SURFACE MOUNTED) FCO FLOORCLEANOUT <br /> SHT SHEET 11. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE <br /> SIM SIMILAR CWR CWR CHILLED WATER RETURN-COOLING <br /> Cy RAS FLOW MEASUREMENT STATION LLE <br /> FCU FAN COIL UNIT <br /> NIT EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FIRINGS, <br /> XX ANALOG SENSING DEVICE FD FLOOR DRAIN SO STA�EPRESSURE RL RL LIQUID LINE-REFRIGERANT STIR Y-TYPE STRAINER TRANSITIONS,VALVES,AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR C)(PIPE OR DUCT MOUNTED) FDPR FIRE DAMPER A COMPLETE,WORKABLE INSTALLATION. <br /> FFD FUNNEL FLOOR DRAIN SO FT SQUARE FOOT/FEET RS IRS SUCTION LINE-REFRIGERANT GLV GLOBE VALVE <br /> FF FINAL FILTER SS STAINLESS STEEL 12. PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL COMPLY WITH THE <br /> ANALOG SENSING DEVICE STD STANDARD HG HG HOT GAS LINE-REFRIGERANT OSY VA OUTSIDE SCREW AND YOKE VALVE <br /> (SURFACE MOUNTED) O <br /> XX FLR FLOOR ® LATEST ACCEPTED VERSION OF THE IBC. COORDINATE WITH ARCHITECTURAL <br /> FPM FEET PER MINUTE THK THICK HWS IXP VA EXPANSION VALVE HWS HOT WATER HEATING SUPPLY PLANS. <br /> FPS FEET PER SECOND C'4 / 1 I I <br /> Q ANALOG SENSING DEVICE(SURFACE MOUNTED) FT FOOT/FEET TP TRAP PRIMER or TEST PLUG HWR HWR HOT WATER HEATING RETURN 13. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING. �J LLJ <br /> L� <br /> (APPROPRIATE FOR MEASURED FLUID) FV FACE VELOCITY TYPICAL 0CITY FOS FCV FLOW CONTROL VALVE FOS FUEL OIL SUPPLY W <br /> SUBSCRIPT LETTER(X)INDICATES: TU TERMINAL UNIT 14. SUPPORT HORIZONTAL LINES OF COPPER TUBING WITH HANGERS SPACED NOT <br /> FOR FOR FUEL OIL RETURN I�I UNION MORE THAN 6-FEET,CENTER TO CENTER FOR ALL PIPE SIZES.ALL PIPES �/ <br /> A-ALARM PRESSURE SENSOR GA GAGE or GAUGE V/ II <br /> D-DIFFERENTIAL PRESSURE GAL GALLON UBC UNIFORM BUILDING CODE SHALL BE SUPPORTED AT ELBOWS,BRANCHES,AND RISERS. J <br /> UFC UNIFORM FIRE CODE G G NATURAL GAS 4- FLANGES <br /> F-FLOW RATE GALV GALVANIZED UMC UNIFORM MECHANICAL CODE LPG LPG UQUID PETROLEUM GAS 15. SUPPORT HORIZONTAL CAST IRON SOIL PIPE WITH HANGER,OR PIER,TWO U Q <br /> H-HUMIDITY GPM GALLONS PER HOUR UPC UNIFORM PLUMBING CODE b THREADED DRAIN PLUG FOR EACH 5-FOOT PIPE LENGTH.LOCATE SUPPORT CLOSE TO JOINTS <br /> L-LOW LIMN GPM GALLONS PER MINUTE UG UNDERGROUND LPS LIPS LOW PRESSURE STEAM SUPPLY <br /> P-PRESSURE(STATIC) j MALE(GARDEN)HOSE CONNECTION WITH CAP EXCEPT,PIPE EXCEEDING 5-FEET IN LENGTH SHALL BE SUPPORTED AT NO <br /> T-TEMPERATURE H HEIGHT UH UNIT HEATER LPR LPR LOW PRESSURE STEAM CONDENSATE RETURN MORE THAN 5-FOOT INTERVALS.SUPPORTS SHALL BE LOCATED ON BOTH LL O <br /> V-VELOCITY&VOLUME FLOW RATE HD HEAD 4 TP TEST PLUG SIDES OF ALL JOINTS AND WITHIN 6'OF THE JOINTS. ` <br /> HP HORSEPOWER VA VALVE MPS MPS(20) MEDIUM PRESSURE STEAM SUPPLY V <br /> HTG HEATING VAC VACUUM NUMBER IN PARENTHESIS INDICATES PSI O 16. PROVIDE WATER HAMMER ARRESTORS(SHOCK ABSORBERS)AT ALL PIPE Q <br /> HVAC HEATING,VENTILATION AND VAV VARIABLE AIR VOLUME MPR MPR(20) MEDIUM PRESSURE STEAM CONDENSATE RETURN T SHOCK ARRESTOR LOCATIONS WHERE VALVE CLOSURES(SUCH AS FLUSH VALVES)MAY CAUSE <br /> AIR CONDITIONING VD VOLUME DAMPER NUMBER IN PARENTHESIS INDICATES PSI WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. (n� <br /> HWG HIGH WALL GRILLE VEL VELOCITY HIPS HPS(100)HIGH PRESSURE STEAM SUPPLY �T TH or TI THERMOMETER(TEMPERATURE INDICATOR) a- <br /> VFD VARIABLE FREQUENCY DRIVE NUMBER IN PARENTHESIS INDICATES PSI <br /> HWR HIGH WALL REGISTER 17. ON THE <br /> PLUMBING CLEANOUT LOCATIONS ARE NOT ALWAYS ESTABLISHED <br /> VTR VENT THRU ROOF <br /> HZ HERTZ LOCATE <br /> THE PLUMBING PLANS IN ORDER TO GIVE THE PLUMBER AS. AS A TO <br /> HPR HPR(100)HIGH PRESSURE STEAM CONDENSATE RETURN II B STIR BASKET STRAINER LOCATE PLUMBING CLEANOUTS IN THE MOST ACCESSIBLE AREAS. AS A LJJ w <br /> ID INSIDE DIAMETER W WIDE NUMBER IN PARETHESIS INDICATES PSI MINIMUM,PROVIDE CLEANOUTS AS REQUIRED BY THE UNIFORM PLUMBING /� <br /> IE INVERT ELEVATION W/ WITH PR PR STEAM CONDENSATE RETURN(PUMPED) I?P PI PRESSURE INDICATOR CODE. CLEANOUTS THAT MUST BE INSTALLED IN PIPES THAT ARE DIFFICULT U W <br /> IN INCH or INCHES W/o WITHOUT TO ACCESS SHALL BE EITHER WALL OR FLOOR CLEANOUTS SERVICED FROM <br /> INSUL INSULATION WB WET BULB ATV ATV ATMOSPHERIC VENT THE FLOOR ABOVE. FLOOR CLEANOUTS SHALL BE LOCATED SO AS TO BE <br /> INV INVERT W� WALL CC�EONT AAV AUTOMATIC AIR VENT SERVICED FROM CORRIDORS,TOILET OR JANITOR ROOMS WHEREVER POSSIBLE. <br /> MA MA COMPRESSED MEDICAL AIR z <br /> KW KILOWATT WGE WASTE GAS EVACUATION LA LA COMPRESSED LABORATORY AIR MANUAL AIR VENT 18. TRAP PRIMERS AND ARRESTORS:TRAP PRIMER ACTUATORS AND WATER LLJ <br /> KWH KILOWATT HOUR WPD WATER PRESSURE DROP Q HAMMER ARRESTORS SHALL BE LOCATED TO BE ACCESSIBLE EITHER THROUGH Q <br /> WT WEIGHT MV MV MEDICAL VACUUM ACCESSIBLE CEILING OR WALL ACCESS DOORS.REFER TO SPECIFICATION FOR <br /> 02 02 OXYGEN ® PUMP(DIAGRAM) WHERE ARRESTORS NEED TO BE LOCATED. \ O <br /> 420 N20 NITROUS OXIDE 19. TRAP PRIMER LINE SIZE TO EACH FLOOR DRAIN OR FUNNEL DRAIN SHALL BE O <br /> 42 N2 NITROGEN kNl FLEXIBLE CONNECTOR 1/2`DIAMETER. N O <br /> CO2 CO2 CARBON DIOXIDE 20. DRAINAGE PIPING SHALL BE PROTECTED FROM CONCRETE USING 10-MIL <br /> A A COMPRESSED AIR INDICATES ASSEMBLY OF PIPING COMPONENTS PLUMBERS TAPE. n <br /> (AS NOTED OR DIAGRAMED) LL LL <br /> V V VACUUM 21. SANITARY PIPING SHALL BE SLOPED AT A MINIMUM OF 1/4"PER FOOT. <br /> LV LV LABORATORY VACUUM 22. DOMESTIC COLD WATER PIPING AND FIRINGS SHALL BE SEAMLESS TYPE"L" <br /> WGE WGE WASTE GAS EVACUATION COPPER WITH 95-5 SOLDER. SOLDER CONTAINING LEAD IS NOT ice.No. 242095 <br /> ACCEPTABLE. <br /> 23. EFFICIENT WATER HEATER SUPPLY PIPING:HOT WATER SUPPLY PIPING SHALL °TAW°" CEI <br /> BE PLUMBED IN COMPLIANCE WITH C404.3 IN CURRENT WSEC. c�e,.ae�er ON <br /> 24. PLUMBING CONTRACTOR SHALL PRESSURE TEST PIPING PRIOR TO COVERING <br /> AND SUBMIT TEST REPORT TO ENGINEER. <br /> 25. COMMISIONING:HOT WATER SUPPLY SYSTEM SHALL BE COMMISSIONED IN PERMIT SET <br /> ACCORDANCE WITH C408.3 IN CURRENT WSEC. 08/22/24 <br /> COVER SHEET <br /> AND GENERAL <br /> INFO <br /> P0. 1 <br />