Permit#: K2404-017 �� �� �� HARBOR'S EDGE BLDG A NFPA z M <br /> Site Address: 3618 W.Mukilteo Blvd Unit E -. .. : , <br /> LL <br /> Applicant: Moore Fire Protection o 1 3 D Z <br /> Application Date:04/10/2024 i SITE SPECIFICATIONS O <br /> Description: New"Harbor's Edge"Residential ?) <br /> Flow-Through Sys.Unit E AHI: City of Everett OWNER/LESSEE: Q <br /> Review Date: 04/25/2024 A RELATED PERMIT: B2304-037 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> WEST MUKILTEO BLVD. CONST.TYPE: V-B Everett,WA 98208 1-1 <br /> 97+00 98+00 99+00 N 76U+OOB017'08"E 1016.80 100+00 STORIES: 3 (425)609-8074 <br /> PARCEL: 00433600004700 <br /> Submittal or GENERAL DESCRIPTION: <br /> EVERETT Bldg A Unit E only New single family attached townhome.The typical and mirrored plans are both shown for <br /> reference.This submittal is for one plan-type only. <br /> Everett Fire Dept.Permit Review o LEGAL DESCRIPTION- <br /> _________________________-___________________-_________________________________________________________________________________________________________________________. _______________________- , <br /> Status:Approved EDGEWATER BLK 000 D-00-LOT 47 <br /> Reviewed By:KBrown <br /> 04/25/2024 1:40:28 <br /> PM FIRE FLOW <br /> 340. 7 <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> APPROVED GRADE = GRADE= P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> PUBLIC WORKS DEPARTMENT <br /> BY:THerman GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> DATE:04/29/2024 <br /> CITY OF EVERETT REVIEWED FOR PERMIT Fizz O BUILDING CODE: 2018 IRC with WA State Amendments C <br /> Z PgD,1$28 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System <br /> 150.8 Passive purge system without backs preventer <br /> O <br /> O O O O © O SPRINKLER COVERAGE: 256 ftz Der sprinkler listing � <br /> wp D <br /> o N 1296 SF 1221 SF 1220 SF 1525 SF 1220 SF 1220 SF 1220 SF 1216 SF <br /> SPRINKLER SPACING: 16-0"max.between heads. <br /> F1 8'-0"max.from any wall. <br /> i i i FF' S3. FF; <br /> PADk151.7 PAD'151.5 PA151.1 PADo150.8 8'-0"min.between heads. <br /> PgD`750.3 PAD>160.3 PAD SPRINKLER�150'g Res'Idn a fasDtE response pendent sprinklers used throughout. N d <br /> �........... ............i i.............. ................ �........... ............. �....... ......... 9 HAZARD CLASSIFICATION:.... .... a+ u <br /> to <br /> 26 Residential use throughout. u° <br /> g � 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. s <br /> / SUPPLY: aC m n <br /> N 77°23'09" 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" LL m` <br /> E 56.51 combined domestic/water meter supplies SYz"poly underground which runs to the system M Y u <br /> r , . riser. <br /> r........... ........... C y uN. an d <br /> a <br /> ML <br /> CD <br /> CPVC COMPATIBILITY: IN <br /> J jIN «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r----------. 1-----------� r--------- specifications booklet.For a complete and up-to-date product search, lease go to/ I P P P ,- <br /> IFF'75 F I FF'1�3.7 PFi 153.3 <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC <br /> $!153 PqD_ 37 PF=15q0 PAD;)51 Ap=75jpiping caused by any products which are not approved for contact with it.Informationo.I I I 4i 151.7 AD=152p 8. 7 � 3 about products approved for contact can be found with the manufacturer. rn d saFF,153. FF 3s FP�1s O 11e GENERAL NOTES AND LIABILITY <br /> Z PAD>15 4 PAt, 3.4 Pq 3.4 12g1 118 SF 1181 SF 1181 SF 1 SF `o .c <br /> 14 151.4 q-151.4 SF 4ti v <br /> 0, ? ? Install CPVC piping in accordance with manufacturer's instructions and UL listing including y 0' 0 <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° 10 a <br /> w a O O concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of Z <br /> V 1282 130 O 3/8"gypsum board. All CPVC pipe shall be concealed. 'n x u - <br /> SF 1 SF 1301 SF GRADE=153.4 GRADE=154.0 >c a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured ` ii `ma <br /> PARCEL NO. SW GRADE=154.0 to to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. 2.5 <br /> F'>A <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related tn� OR <br /> GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> e on with no insulation on the warm side of the a facing the heated interior. ' .. .' <br /> GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , I <br /> SW GRADE=154.0 pipe Y P�P 9 a. I <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.5 GRADE=155.9 a c <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately y ;I t <br /> O O support the fire sprinkler system or any appurtenances thereof. <br /> F C, J ,� <br /> G - 1301 SF 7301 SF 1300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapterae � <br /> 20 O © O O 12. tak <br /> y 1180 SF 1181 7781 1241 F�158 3 PFF`158.3 FF�758.3 11/z"Poi ore equivalent supply brought in b others.* <br /> � jl FFF1S72 FF;S PF^1S� FF,f�.6 PAq_156.3 AD;J56.3 PAD`156.3 Y q PPY 9 Y %... 'D .. <br /> Pgtl`155.p PADc�552 PA�=1556 PAI),: • 11/2"combination domestic/fire sprinkler shut off valve O M ..m•.#z <br /> by others.Mu t be ocated efore the domestic tee. J10 <br /> s b x <br /> -------- ----- r •No monitoring is required. N ti <br /> i a <br /> o es # v N Uw <br /> �i........ tic pressure-reducingo tva v <br /> E 11/z"to nues to d by others An <br /> Y <br /> i domesIves,water softeners, <br /> E 4 O <br /> ws i O leak detectors,or other devices that will deter water lb D u a, m O <br /> ............i `........... ............. . <br /> G = 3 •flow are to be on the domestic-only side of the tee. <br /> 8 U Brass tee top outlet to be female-threaded to d•� U r= o m <br /> " O IL accommo Ch,date male threaded CPVC adapter m o v <br /> connection. N oo w <br /> V.-1 Q 0 7 J <br /> C a 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. W LLi ;,� v Z <br /> O MFP scope of work to begin here. 2 E o v <br /> ¢ o <br /> 1"check valve. M Q d u ui <br /> w <br /> r-I LLJ I <br /> IN76°1648"E -- IF ® 1"tee with flow switch wired to exterior bell by .--I V7 o w a to <br /> ` o w <br /> others. <br /> 220.10 E isZ M <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection ` N <br /> u ®cup attached to sanitary sewer,left by plumber and O Q m <br /> m sized to accommodate the system flow demand of 27 ,^ ¢ <br /> \\ a O d gpm. V 3: <br /> SITE PLAN UNDERGROUND NOTES A m O 1"x 1"x 1/2"tee with 1h"x 1/4"bushing for pressure U <br /> gauge.Three way valve included for pressure gauge. <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. .r 11 I w <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND LU y <br /> SCALE:1/2"=1'-0" 0 <br /> ❑B 6-in circulating water main • Part Tag `QJ ¢ <br /> WARNING SIGN: STUB IN: <br /> v <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w m <br /> ❑C Tap to 1-in combined domestic/fire service(Typical for all units) shutoff valve and shall state the following: #FLUSH TEST: Hydraulic Node Tag W <br /> 'a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain Underground installer will be required to have a flush test completed and witnessed Op <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: y <br /> ❑# Underground Note Tag <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the � f <br /> remote toilet location.Plumber is to connect from adapter to toilet. 3 <br /> Do not remove this sign. Remote Area Tag Q <br /> Riser location-see this page for detail(Typical for all units) T <br /> M <br />