My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3618 W MUKILTEO BLVD E 2024 HARBORS EDGE TOWNHOMES Plans 2025-07-02
>
Address Records
>
W MUKILTEO BLVD
>
3618
>
HARBORS EDGE TOWNHOMES
>
Plans
>
3618 W MUKILTEO BLVD E 2024 HARBORS EDGE TOWNHOMES Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 7:34:18 AM
Creation date
6/16/2025 11:59:36 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3618
Unit
E
Tenant Name
HARBORS EDGE TOWNHOMES
Permit
K2404-017
Year
2024
Notes
NEW "HARBOR'S EDGE" RESIDENTIAL FLOW-THROUGH SYS, UNIT E
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o M <br /> A A A z <br /> E9a E9T E9a LL <br /> PLAN 1727 PLAN 1727 PLAN 1727r Q LL <br /> O <br /> a � <br /> — o N <br /> DESK (EGRESS) y (EGRESS) Blue arc indicates <br /> �° drop to toilet <br /> bINK <br /> D,N installed by <br /> PIPING IN GARAGE 70 B� wl DISP. POCKET o plumber(TYP) <br /> REVERSE-TENTED.SEE DETAIL OFFICE <br /> THIS PAGE.NO INSULATION TO KITCHEN BEDROOM w BEDROOM <br /> BE INSTALLED BETWEEN PIPING 0 <br /> w THREE z TWO <br /> AND WARM SPACE ABOVE(TYP). Oz o i <br /> LINEO5� 0 <br /> L INWRI HMPOSOR J L -------------------- a <br /> �nlvPmcflTrosmoN———————————— o� o% <br /> TOP OF WINDOWS indicates droATLOWERFLOOR �,Iijetoair,C <br /> oet installed by Q Q o 0 <br /> TO BE AT 7'-0" plumber(TYP) c <br /> UNLESS OTHERWISE LL PANT <br /> NOTED Rise LF-MF:1 x 10'-1 Rise LF-MF:1 x 10'-1 w Rise LF-.1:1 x 10'-1 Rise LF-MF:I x 10'-1L - <br /> 2 2 2 2 <br /> GA��\\GE o ow 11 ft= 11 ft' 0 M. 11 ft' 11 ft= 11 ft= 11 ftz <br /> g� O 2 2 454 1 ft= —-, 41 ft <br /> ��// Rise MF-UF:Os/a x 9'-0 I " � Rise MF-UF:03k x 9'-0 ATTIC�L\ / 0 <br /> 1 AC S ACCESS 1 <br /> o ¢ o� m o BATH INS&WS 2x4 <br /> HEAT® DINING Oo OWN • .O ❑ENO 6 UDOWN 6 FURRING o <br /> DETECTOR ——— ——— �IS ROOM_ _ 50 CFM V7� ®Osh 0 TYP. <br /> TUB/SHOWER W O 3 <br /> TOP OF WINDOWS 3 <br /> / \ AT MAIN FLOOR $ <br /> TO BE AT V-0„ J v <br /> O ——— ——— O / UNLESS OTHERWISE y d <br /> 41 <br /> py/ 43 ftz° ——— ——— \� NOTED <br /> \\\ F N 1 x o 43 ft' /// \\ c lJ o o BATH 5iftz m m 5ift2 V)u° <br /> / t 2 O <br /> 50 CFM 6 io s.o. a 6 a FAN <br /> I' SYSTEM a Vi0 6 6 E c <br /> % O O MINI-SPLIT u 5 CFM y o <br /> 2 EC.HE T 6 2 I.• O O = 2 HANA RLERS 6 6 f ry <br /> P MPOH ig 2 o 2 O 3 0 <br /> 2 6 ' 6 2 ° c " a <br /> GREAT 8 <br /> m <br /> AIR HANDLER UCTLESS MINI-SPLIT ai> <br /> ROOM Os/a VRI..IMF-UF: <br /> 03A 0% O Oa/a pI c FOYER a w 'fl 0 <br /> 83 PRIMARY cBEDROOM a � O%x 9'-O 93 BEDROOM Rise MF-UF:0a/a x 9'-0 � N <br /> FOUR ! <br /> c <br /> UTDOOR DUCTLESS CONDENSER 0 W L <br /> o sE <br /> COVERED ---COVERED — --------- rn F d <br /> (EGRESS) PORCH — c a <br /> 3 3 .. <br /> a --- 3 ---- ---- 3 --- ^. �s <br /> o • <br /> L-------- 77 <br /> L--------J <br /> I =� <br /> LINE OF a ABV.LINE Z O n a E. <br /> ca <br /> BUM <br /> U1 Y rn q <br /> ABV.P OUT GUARDRAIL 36"HIGH MIN. c _ <br /> RAILS SHALL NOT ALLOW <br /> � to._ <br /> PASSAGE OF A SPHERE w.5 H =N <br /> 4 INCHES OR MORE IN f j m .9` <br /> DIAMETER-INSTALL PER MFG.SPECS. o `a= <br /> SEE NOTE ON S03 FOR STRUCTURAL ATTACHMENTS PROVIDED BY BTL Uj•I- rn a <br /> 4' <br /> LOWER FLOOR (MIRROR) LOWER FLOOR (TYP) 4' MAIN FLOOR (MIRROR) MAIN FLOOR (TYP) UPPER FLOOR (MIRROR) UPPER FLOOR (TYP) a ;ta <br /> SCALE:1/4"=V-0" SCALE:1/4"=V-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" 41 <br /> PART TAG KEYNOTES: Hanger No.17W <br /> Pl pe Strap <br /> •3/4"x 3/4"x 1/2"S x S x T Reducing Tee left for plumber to connect to toilet Pipe Strap <br /> e <br /> P P <br /> .............------ <br /> Hydraulic <br /> Information Maximum Support Spacing for Wood Screw Pipe <br /> 1'-6" 1'-0" CPVC Piping #12 x 1Ya" m 'D #a <br /> 3' 1' OCCUPANCY CLASSIFICATION Residential Pipe Between From From O x <br /> 9 <br /> i 6 <br /> TOTAL HEADS FLOWING 2 NFPA 13D CODE QUICK REFERENCES Size Hangers A.S. End of / // 01 a N . <br /> 8.3 LOCATION OF SPRINKLERS: Inline Line rI m c a <br /> K-FACTOR 4.9 H o w <br /> 9" - 8.3.1 Sprinklers shall be installed in all areas '�<" Soh' 3' 6" # U <br /> o TOTAL WATER REQUIRED 26.74 1" 6' 4' 9" E N m p <br /> Ell /zexcept where omission is permitted by 8.3.2 ill, 6�h' S' 12" Wood Joist or Beam m Li u v `y O <br /> —1'-6" TOTAL PRESSURE REQUIRED 60.662 through 8.3.8. ill, 7' 7' 12" �� w of o w h� <br /> BASE of RISER(gpm) 26.74 2" 8' 7' 12" O o Ln <br /> 1 8.3.2 Sprinklers shall not be required in m o a <br /> BASE of RISER(psi) 28.177 O , 2�h" 9' 7' 12" o <br /> (P ) bathrooms of 55 ft and less. 3" 10' 7' 12" Hanger No.19W U. T E w <br /> RANGE FIREPLACE UN-INSULATED DUCT UN-INSULATED HOT WATER PIPE SAFETY MARGIN(psi) +56.292(48.1%) Offset Pipe Hanger }Q Ud o- N <br /> w v w <br /> F w <br /> 2 sprinklers in the design area flowing 13 gp 8.3.3 Sprinklers shall not be required in clothes 3:m minimum for 16x16 closets,linen closets,and pantries that meet all Hanger No.09W Pipe ^,3 v M O N <br /> spacing per NFPA 13D and the sprinkler's listing.Refer to the Pipe Strap M Z el <br /> 2'-0" s rinkler lis[in fora royal chart.The hi hest,most remote unit of the following conditions: P P Lu W ry m v <br /> p g pp g O2 (1)The area of the space does not exceed 24 ft2. Wood Screw 2 J E o ¢ o <br /> DIFFUSER on the parcel has been used for worst-case scenario hydraulic (2)The walls and ceilings are surfaced with #18 x 1Y2" U <br /> 6„ calculations. noncombustible or limited-combustible materials Wood Screw Pipe Offset Pipe M Q u_d u T yi <br /> At 1'-0" as defined in NFPA 220. #18 x 1�/2" Hanger LU w a m <br /> WALL 6�,I �,I ��, Pipe Strap —1 w w m n m c <br /> rf o (Short) .—I t� O w a In f] w <br /> WFi MIN.R-11 INSULATION BATT.OVER PIPE. NO INSULATION TO BE 8.3.4 Sprinklers shall not be required in garages, o <br /> 6" 3" SECURE TO ROOF TRUSS IF BLOWN IN O Open attached porches,Carports,and similar p <br /> 1 ,INSTALLED BETWEEN PIPING <br /> L INSULATION IS USED. Structures. <br /> AND WARM SPACE <br /> R-11 IS A \COLD AREA SPRINKLER PIPING TO BE <br /> m <br /> 8.3.5 Sprinklers shall not be required in attics ,^ 3 <br /> MINIMUM AND TIGHT TO WARM FLOOR ABOVE with or without storage,penthouse equipment Wood Joist,Beam or Deck Wood Joist,Beam or Deck \.J <br /> TO BE MODIFIED WARM AREA ABOVE rooms,elevator machine rooms,concealed <br /> DIFFUSER WALL DIFFUSER WATER HEATER LIGHT UNDER 250W LIGHT OVER 25OW FOR THE LOCAL /////// spaces dedicated exclusively to and containing U v <br /> AREA BY THE /////// O only dwelling unit ventilation equipment, TYP. CPVC HANGER DETAILS 1E,W J m <br /> INSULATION // / floor/ceiling spaces,elevator shafts,crawl SCALE:NONE w <br /> HEADS LOCATED OUTSIDE HATCHED AREAS MAY BE ORDINARY RATED SPRINKLERS CONTRACTOR. spaces,and other concealed spaces that are not L ui <br /> used or intended for living purposes. KEYNOTE LEGEND r (LL1 - <br /> =NO SPRINKLERS ALLOWED =INTERMEDIATE RATED SPRINKLERS ❑ =ORDINARY RATED SPRINKLERS / 8.3.6 Sprinklers shall not be required in unheated O v <br /> ////i/i � Part Tag Q <br /> enclosures at the building at entrances/exits as 11 <br /> SPRINKLER PIPING ON WARM AREA O long as the dwelling unit has another LL U..I v <br /> RESIDENTIAL HEAT SOURCE DETAILS entrance/exit. O m <br /> BOTTOM CHORD OF # Hydraulic Node Tag <br /> ROOF TRUSS COLD AREA BELOW W a <br /> SCALE:NONE *SPRINKLERS BETWEEN 175-225°F ARE INTERMEDIATE. 8.2.5.7 Shadow Areas.Shadow areas Shall be A/ <br /> 6 permitted in the protection area of a sprinkler as O Fa <br /> Reference Tag LL o <br /> TYP. TENTING DETAIL REV. TENTING DETAIL long as the cumulative dry areas do not exceed LL <br /> SCALE:NONE SCALE:NONE 15 ft2 per sprinkler. ❑ O <br /> # Underground Note Tag <br /> Remote Area Tag Q <br /> M <br />
The URL can be used to link to this page
Your browser does not support the video tag.