Granite Construction Company 6/17/2025
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Granite Construction Company 6/17/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2025 8:01:20 AM
Creation date
6/17/2025 7:42:44 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Granite Construction Company
Approval Date
6/17/2025
Council Approval Date
6/11/2025
Department
Public Works
Department Project Manager
Gina Loring
Subject / Project Title
2025 Federal Overlay, W Mukilteo Blvd - Glenwood Ave to Dogwood Dr
Public Works WO Number
3842
Tracking Number
0004858
Total Compensation
$1,211,580.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
464
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
2025 FEDERAL OVERLAY, W MUKILTEO BLVD – GLENWOOD AVE TO DOGWOOD DR <br /> PAGE SP83 OF SP123 SPECIAL PROVISIONS <br />WORK ORDER #3842 April 15, 2025 FEDERAL AID# NHPP-2776(011) <br />Roadway cores for density may be obtained by either the Contracting Agency or the 1 <br />Contractor in accordance with WSDOT SOP 734. The core diameter shall be 4-inches 2 <br />minimum, unless otherwise approved by the Engineer. Roadway cores will be tested by 3 <br />the Contracting Agency in accordance with WSDOT FOP for AASHTO T 166. 4 <br /> 5 <br />If the Contract includes the Bid item “Roadway Core”, the cores shall be obtained by the 6 <br />Contractor in the presence of the Engineer on the same day the mix is placed and at 7 <br />locations designated by the Engineer. If the Contract does not include the Bid item 8 <br />“Roadway Core”, the Contracting Agency will obtain the cores. 9 <br /> 10 <br />For a lot in progress with a CPF less than 0.75, a new lot will begin at the Contractor’s 11 <br />request after the Engineer is satisfied that material conforming to the Specifications can 12 <br />be produced. 13 <br /> 14 <br />HMA mixture accepted by commercial evaluation and HMA constructed under conditions 15 <br />other than those listed above shall be compacted on the basis of a test point evaluation 16 <br />of the compaction train. The test point evaluation shall be performed in accordance with 17 <br />instructions from the Engineer. The number of passes with an approved compaction 18 <br />train, required to attain the maximum test point density, shall be used on all subsequent 19 <br />paving. 20 <br /> 21 <br />HMA for preleveling shall be thoroughly compacted. HMA that is used for preleveling 22 <br />wheel rutting shall be compacted with a pneumatic tire roller unless otherwise approved 23 <br />by the Engineer. 24 <br /> 25 <br />Test Results 26 <br />For a sublot that has been tested with a nuclear density gauge that did not meet the 27 <br />minimum of 92 percent of the reference maximum density in a compaction lot with a CPF 28 <br />below 1.00 and thus subject to a price reduction or rejection, the Contractor may request 29 <br />that a core be used for determination of the relative density of the sublot. The relative 30 <br />density of the core will replace the relative density determined by the nuclear density 31 <br />gauge for the sublot and will be used for calculation of the CPF and acceptance of HMA 32 <br />compaction lot. 33 <br /> 34 <br />When cores are taken by the Contracting Agency at the request of the Contractor, they 35 <br />shall be requested by noon of the next workday after the test results for the sublot have 36 <br />been provided or made available to the Contractor. Core locations shall be outside of 37 <br />wheel paths and as determined by the Engineer. Traffic control shall be provided by the 38 <br />Contractor as requested by the Engineer. Failure by the Contractor to provide the 39 <br />requested traffic control will result in forfeiture of the request for cores. When the CPF for 40 <br />the lot based on the results of the HMA cores is less than 1.00, the cost for the coring will 41 <br />be deducted from any monies due or that may become due the Contractor under the 42 <br />Contract at the rate of $200 per core and the Contractor shall pay for the cost of the 43 <br />traffic control. 44 <br /> 45 <br />5-04.3(10)A HMA Compaction – General Compaction Requirements 46 <br />Compaction shall take place when the mixture is in the proper condition so that no undue 47 <br />displacement, cracking, or shoving occurs. Areas inaccessible to large compaction 48
The URL can be used to link to this page
Your browser does not support the video tag.