My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10121 EVERGREEN WAY BASE FILE 2025-08-05
>
Address Records
>
EVERGREEN WAY
>
10121
>
BASE FILE
>
10121 EVERGREEN WAY BASE FILE 2025-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2025 10:01:09 AM
Creation date
6/17/2025 8:22:46 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10121
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Architectural: <br />1. The "Building Code Information" section on Sheet A-000 appears to state that either sprinkler and fire alarms <br />systems are existing or will be provided. Based on a review of the building and record documents, it does not <br />appear that either system is existing. If this is an error in the drawings, please confirm that these items should <br />be redlined to state "NO". Otherwise, clarify the intended construction. —SDH Response: This was in error and <br />is not sprinklered or has a fire alarm. <br />2. The existing fire -rating of the west demising wall is not clear from the historical record. It appears that this wall <br />possibly should have been a rated wall to separate the A-2 and B spaces (formerly A-3 and B-3, respectively, per <br />the 1980's UBC codes). It is noted that while the A-2 is in a compartmentalized area enclosed by two-hour "area <br />separation" walls with parapets projecting above the roof, it does not appear to be separated from the B- <br />occupancies within this area, nor does this area appear to be sprinklered. Existing walls being repaired are not <br />required to be upgraded to current code per the IEBC if they were correctly constructed per the code under <br />which they were originally permitted. However, it is not clear that the original construction was code - <br />compliant. We recommend reviewing the existing construction for this wall and the original code requirements, <br />and designing any repairs including upgrades as appropriate. Details for any proposed fire -rated construction <br />should include references to listed tested assemblies per IBC Section 703.3. - SDH Response: See updated <br />sheet A-103 and A-801 with updated details E7/A-801 and C1/A-801. <br />The south "area separation" wall is a two-hour rated wall per the original construction drawings. A detail should <br />be provided including a reference to a listed tested assembly per IBC Section 703.3. Note that this wall appears <br />to be continuous through the roof structure. The continuity detail if provided should be designed accordingly. <br />- SDH Response: See updated sheet A-801 with updated details E7/A-801 and C1/A-801. <br />Please contact me if you have questions. Thank you. <br />Drew Martin, P.E., S.E. <br />® Associate Engineer —Commercial Plans Examiner I Permit Services <br />425.257.8810 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br />EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm — 3 pm; Tu: 1:OOpm-3:OOpm <br />everettwa.gov/permits I Facebook I Twitter <br />Note: Emails and attachments sent to and from the City of Everett are public records and maybe subject to disclosure pursuant to the Public <br />Records Act. <br />Category 2: For official use only/ disclosure permissible by law. <br />Category 2: For official use only / disclosure permissible by law. <br />
The URL can be used to link to this page
Your browser does not support the video tag.