My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8407 BROADWAY SECURE SPACE STORAGE 2026-01-02
>
Address Records
>
BROADWAY
>
8407
>
SECURE SPACE STORAGE
>
8407 BROADWAY SECURE SPACE STORAGE 2026-01-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 10:56:06 AM
Creation date
6/17/2025 8:39:18 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8407
Tenant Name
SECURE SPACE STORAGE
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1489
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP171 <br />Page 7 of 10 <br />SPRINKLER FINISH <br />K <br />TYPE <br />NATURAL <br />I CHROME <br />WHITE <br />LEAD <br />FACTOR <br />BRASS <br />PLATED <br />POLYESTER <br />COATED <br />PENDENT (TY1231) <br />and <br />28 <br />UPRIGHT(TY1131) <br />1/2" NPT <br />175 PSI (12,1 BAR) <br />N/A <br />RECESSED <br />PENDENT (TY1231) <br />PENDENT (TY2231) <br />and <br />4.2 <br />UPRIGHT (TY2131) <br />1/2" NPT <br />175 PSI (12,1 BAR) <br />N/A <br />RECESSED <br />PENDENT (TY2231) <br />PENDENT(TY3231) <br />175 PSI <br />5.6 <br />and <br />UPRIGHT (TY3131) <br />250 PSI (17,2 BAR) <br />(12,1 BAR) <br />1/2" NPT <br />OR 175 PSI (12,1 BAR) <br />RECESSED <br />(SEE NOTE 1) <br />PENDENT (TY3231) <br />N/A <br />PENDENT (TY4231) <br />175 PSI <br />and <br />UPRIGHT (TY4131) <br />(12,1 BAR) <br />8.0 <br />3/4" NPT <br />175 PSI (12,1 BAR) <br />RECESSED <br />N/A <br />PENDENT (TY4231) <br />8.0 <br />PENDENT (TY4931) <br />175 PSI <br />1/2" NPT <br />and <br />175 PSI (12,1 BAR) <br />(12,1 BAR) <br />UPRIGHT( <br />NOTES: <br />1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the <br />Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. <br />TABLE C <br />MAXIMUM WORKING PRESSURE <br />The Series TY-FRB Recessed Pendent <br />Sprinklers must be installed in accor- <br />dance with the following instructions. <br />1. After installing the Style 10, 20, 30, <br />or 40 Mounting Plate, as applica- <br />ble, over the sprinkler threads and <br />with pipe -thread sealant applied to <br />the pipe threads, hand -tighten the <br />sprinkler into the sprinkler fitting. <br />2. Tighten the sprinkler into the sprin- <br />kler fitting using only the W-Type 7 <br />Recessed Sprinkler Wrench (Fig- <br />ure 15). With reference to Figures 1 <br />to 4, apply the W-Type 7 Recessed <br />Sprinkler Wrench to the sprinkler <br />wrench flats. <br />3. After ceiling installation and finish- <br />ing, slide on the Style 10, 20, 30, or <br />40 Closure over the Series TY-FRB <br />Sprinkler and push the Closure over <br />the Mounting Plate until its flange <br />comes in contact with the ceiling. <br />Care and <br />Maintenance <br />The TYCO Series TY-FRB must be <br />maintained and serviced in accordance <br />with the following instructions. <br />Before closing a fire protection system <br />main control valve for maintenance <br />work on the fire protection system <br />that it controls, obtain permission to <br />shut down the affected fire protection <br />systems from the proper authorities <br />and notify all personnel who may be <br />affected by this action. <br />Absence of the outer piece of an <br />escutcheon, which is used to cover <br />a clearance hole, can delay sprinkler <br />operation in a fire situation. <br />Exercise care to avoid damage to <br />sprinklers before, during, and after <br />installation. Never paint, plate, coat, <br />or otherwise alter automatic sprinklers <br />after they leave the factory. <br />Replace sprinklers that: <br />• were modified or over -heated. <br />• were damaged by dropping, striking, <br />wrench twisting, wrench slippage, or <br />the like. <br />• are leaking or exhibiting visible signs <br />of corrosion. <br />• were exposed to corrosive products <br />of combustion but have not oper- <br />ated, if you cannot easily remove <br />combustion by-products with a cloth. <br />• have a cracked bulb or have lost liq- <br />uid from the bulb. Refer to the Instal- <br />lation section in this data sheet. <br />
The URL can be used to link to this page
Your browser does not support the video tag.