Laserfiche WebLink
Project: Four Corners - Bldg A <br /> Description: Wall Wind Load <br /> Made By: SGT <br /> Date: 20-Apr-2020 <br /> Components&Cladding-Part 4: Buildings with h<_160 ft(Simplified) <br /> References:ASCE 7-10 Section 30.7 <br /> Overhang effective wind area= 4.0 (ft`) (affects reduction factors for Povh and ps) <br /> p,,,h <br /> P, <br /> p„ <br /> Overhang Components&Cladding Loads(psf)* <br /> Zone Tabulated Ptable Reduction Factor(RF) Pnet(LRFD) Vert Component(LRFD) <br /> 1 20.3 -35.3 A, 1.00 A, 1.00 15.2 -26.5 14.5 -25.1 <br /> Povh 2 20.3 -59.3 A, 1.00 A, 1.00 15.2 -44.5 14.5 -42.2 <br /> 3 20.3 -89.2 B, 1.02 B, 1.02 17.9 -78.6 17.0 -74.5 <br /> 4 35.3 -38.3 D, 1.07 C, 1.05 28.4 -30.2 28.4 -30.2 <br /> ps 5 32.3 -59.3 D, 1.07 E, 1.10 26.0 -49.0 26.0 -49.0 El <br /> Net Pressure on Overhang(povh+PS)(Psf) <br /> Zone Ptabie RF p1et(LRFD) Vert Component(LRFD) Roof Normal Comp. (LRFD) <br /> povh 2 59.3 A, 1.00 44.5 42.2 44.5 <br /> PS 4 35.3 D, 11.07 1 28.4 28.4 26.9 <br /> Total 2,4 70.6 71.4 <br /> Net Pressure on Overhang(povh+Ps)(psf) <br /> Zone t32.3 <br /> RF pet(LRFD) Vert Component(LRFD) Roof Normal Comp. (LRFD) <br /> povh 3 J B, 1.02 -78.6 74.5 78.6 <br /> PS 5 D, 1.07 26.0 26.0 24.6 <br /> Total 3,5 100.5 103.2 <br /> Bldg A C&C-Wall.xlsm-Part 4-Roof and Wall Last Saved Date: 20-Apr-2020 <br />